{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/49827"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/49827","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Transistor-based biosensing: expanding the functionality of field effect transistors","abstract":"Since the invention of Polymerase Chain Reaction (PCR)-based amplification of nucleic acids by Kary Mullis in 1983(1), researchers have spent significant efforts to improve the sensitivity and selectivity of PCR assay and have dramatically enhanced its application(2). PCR is now an integral tool of modern biotechnology processes and biological identification. Due to the growing demands for on-site, rapid diagnosis, attention has been paid in realizing portable, fast, and low cost PCR machines. Through expanding the uses of the field effect transistor platform to include a novel design of heating/cooling, ultra-localized cell lysis, and electrical detection of nucleic acid amplification using an on-chip electrode, this thesis aims to enable the next generation of portable biosensors for primary care and on-site diagnostics. Chapter 2 presents an overview of the current state-of-the-art of electrical biosensors. In keeping with the goal of complete, integrated systems, methods for both sample preparation and detection were evaluated. Electrical sample preparation methods provide a unique opportunity to utilize electrical fields for cell lysis, concentration, and sample flow without the need for additional moving parts or reagents. Electrical detection methods offer a means of reducing reagents by eliminating the need for optical labels. Together, electrical sample preparation and detection will aid the development of portable, low-cost integrated biosensors. Chapters 3 and 4 look at utilizing transistors as platform for sample preparation and manipulation through DNA denaturation and cell lysis. Through application of a 10MHz, AC field between the shorted source-drain and the back-gate of the chip, fringing electric fields located just above the transistor surface are generated. These fringing electric fields can be used for dielectric relaxation of water molecules to generate heat for DNA denaturation as discussed in chapter 3, or to generate a transmembrane potential across a cellular membrane for ultra-localized cell lysis as discussed in chapter 4. These methods expand the functionality of the transistor platform by extending their uses into the realm of sample manipulation. Since the development of ISFETs for biosensing applications, transistors have been used for detection of biological analytes. Chapter 5 extends this functionality to electrical detection of nucleic acid amplification with an on-chip quasi-reference electrode. This method eliminates the need for a bulky/difficult to fabricate reference electrode and enables parallel detection of a large array of individual nucleic acid amplification reaction volumes. This method promises to reduce cost of PCR assays by eliminating optical components as well as improve the portability of the equipment by localizing the detection element to a disposable chip. As discussed in the future outlook presented in chapter 6, the silicon CMOS compatible technologies introduced can be made portable, rapidly heat and cool reaction volumes, and remain inexpensive so the ultimate vision of an array of PCR reaction chambers, where the target sample can be interrogated against an array of primers, can be realized. This thesis has added three new functionalities to the transistor platform. 1) Rapid DNA denaturation 2) Localized single cell lysis and 3) Electrical detection of amplification by-products with an on-chip electrode.","abstract_html":"Since the invention of Polymerase Chain Reaction (PCR)-based amplification of nucleic acids by Kary Mullis in 1983(1), researchers have spent significant efforts to improve the sensitivity and selectivity of PCR assay and have dramatically enhanced its application(2). PCR is now an integral tool of modern biotechnology processes and biological identification. Due to the growing demands for on-site, rapid diagnosis, attention has been paid in realizing portable, fast, and low cost PCR machines. Through expanding the uses of the field effect transistor platform to include a novel design of heating/cooling, ultra-localized cell lysis, and electrical detection of nucleic acid amplification using an on-chip electrode, this thesis aims to enable the next generation of portable biosensors for primary care and on-site diagnostics. Chapter 2 presents an overview of the current state-of-the-art of electrical biosensors. In keeping with the goal of complete, integrated systems, methods for both sample preparation and detection were evaluated. Electrical sample preparation methods provide a unique opportunity to utilize electrical fields for cell lysis, concentration, and sample flow without the need for additional moving parts or reagents. Electrical detection methods offer a means of reducing reagents by eliminating the need for optical labels. Together, electrical sample preparation and detection will aid the development of portable, low-cost integrated biosensors. Chapters 3 and 4 look at utilizing transistors as platform for sample preparation and manipulation through DNA denaturation and cell lysis. Through application of a 10MHz, AC field between the shorted source-drain and the back-gate of the chip, fringing electric fields located just above the transistor surface are generated. These fringing electric fields can be used for dielectric relaxation of water molecules to generate heat for DNA denaturation as discussed in chapter 3, or to generate a transmembrane potential across a cellular membrane for ultra-localized cell lysis as discussed in chapter 4. These methods expand the functionality of the transistor platform by extending their uses into the realm of sample manipulation. Since the development of ISFETs for biosensing applications, transistors have been used for detection of biological analytes. Chapter 5 extends this functionality to electrical detection of nucleic acid amplification with an on-chip quasi-reference electrode. This method eliminates the need for a bulky/difficult to fabricate reference electrode and enables parallel detection of a large array of individual nucleic acid amplification reaction volumes. This method promises to reduce cost of PCR assays by eliminating optical components as well as improve the portability of the equipment by localizing the detection element to a disposable chip. As discussed in the future outlook presented in chapter 6, the silicon CMOS compatible technologies introduced can be made portable, rapidly heat and cool reaction volumes, and remain inexpensive so the ultimate vision of an array of PCR reaction chambers, where the target sample can be interrogated against an array of primers, can be realized. This thesis has added three new functionalities to the transistor platform. 1) Rapid DNA denaturation 2) Localized single cell lysis and 3) Electrical detection of amplification by-products with an on-chip electrode.","abstract_has_math":false,"creators":["Salm, Eric"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Bioengineering","degree_department":null,"school":null,"contributors":["Bashir, Rashid","Alam, Muhammad A.","Cunningham, Brian T.","Liu, Gang Logan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-05-30T17:19:50Z","date_published":"2014-05-30T17:19:50Z","updated_at":"2026-07-22T22:25:40Z","subjects":["Electrical biosensor","ion-sensitive field-effect transistor (ISFET)","Field Effect Transistor (FET)","reference field-effect transistor (REFET)","solid-state electrode","nucleic acid amplification","Loop-mediated isothermal amplification (LAMP)","Polymerase chain reaction (PCR)","single cell lysis","droplet","DNA denaturation"],"languages":["en"],"rights":["Copyright 2014 Eric Salm"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/49827","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bashir, Rashid","Alam, Muhammad A.","Cunningham, Brian T.","Liu, Gang Logan"]},{"key":"dc:creator","label":"Author","values":["Salm, Eric"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-05-30T17:19:50Z","2016-09-22T20:59:16Z","2014-05"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Bioengineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical biosensor","ion-sensitive field-effect transistor (ISFET)","Field Effect Transistor (FET)","reference field-effect transistor (REFET)","solid-state electrode","nucleic acid amplification","Loop-mediated isothermal amplification (LAMP)","Polymerase chain reaction (PCR)","single cell lysis","droplet","DNA denaturation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2014 Eric Salm"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/49827"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Since the invention of Polymerase Chain Reaction (PCR)-based amplification of nucleic acids by Kary Mullis in 1983(1), researchers have spent significant efforts to improve the sensitivity and selectivity of PCR assay and have dramatically enhanced its application(2). PCR is now an integral tool of modern biotechnology processes and biological identification. Due to the growing demands for on-site, rapid diagnosis, attention has been paid in realizing portable, fast, and low cost PCR machines. Through expanding the uses of the field effect transistor platform to include a novel design of heating/cooling, ultra-localized cell lysis, and electrical detection of nucleic acid amplification using an on-chip electrode, this thesis aims to enable the next generation of portable biosensors for primary care and on-site diagnostics. Chapter 2 presents an overview of the current state-of-the-art of electrical biosensors. In keeping with the goal of complete, integrated systems, methods for both sample preparation and detection were evaluated. Electrical sample preparation methods provide a unique opportunity to utilize electrical fields for cell lysis, concentration, and sample flow without the need for additional moving parts or reagents. Electrical detection methods offer a means of reducing reagents by eliminating the need for optical labels. Together, electrical sample preparation and detection will aid the development of portable, low-cost integrated biosensors. Chapters 3 and 4 look at utilizing transistors as platform for sample preparation and manipulation through DNA denaturation and cell lysis. Through application of a 10MHz, AC field between the shorted source-drain and the back-gate of the chip, fringing electric fields located just above the transistor surface are generated. These fringing electric fields can be used for dielectric relaxation of water molecules to generate heat for DNA denaturation as discussed in chapter 3, or to generate a transmembrane potential across a cellular membrane for ultra-localized cell lysis as discussed in chapter 4. These methods expand the functionality of the transistor platform by extending their uses into the realm of sample manipulation. Since the development of ISFETs for biosensing applications, transistors have been used for detection of biological analytes. Chapter 5 extends this functionality to electrical detection of nucleic acid amplification with an on-chip quasi-reference electrode. This method eliminates the need for a bulky/difficult to fabricate reference electrode and enables parallel detection of a large array of individual nucleic acid amplification reaction volumes. This method promises to reduce cost of PCR assays by eliminating optical components as well as improve the portability of the equipment by localizing the detection element to a disposable chip. As discussed in the future outlook presented in chapter 6, the silicon CMOS compatible technologies introduced can be made portable, rapidly heat and cool reaction volumes, and remain inexpensive so the ultimate vision of an array of PCR reaction chambers, where the target sample can be interrogated against an array of primers, can be realized. This thesis has added three new functionalities to the transistor platform. 1) Rapid DNA denaturation 2) Localized single cell lysis and 3) Electrical detection of amplification by-products with an on-chip electrode.","Item withdrawn by Laura Spradlin (lspradl2@illinois.edu) on 2014-02-11T21:23:55Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 3 14_01_27 Eric Salm Thesis.pdf: 9586621 bytes, checksum: e65784d99a421bb69c6e3ecb86275db6 (MD5) Salm_Eric.doc: 6871552 bytes, checksum: 18825d724b4357db08e4a87e8537555e (MD5) Salm_Eric.pdf: 9586621 bytes, checksum: e65784d99a421bb69c6e3ecb86275db6 (MD5)","Made available in DSpace on 2014-05-30T17:19:50Z (GMT). No. of bitstreams: 3 Eric_Salm.pdf: 3037278 bytes, checksum: eff4c448d43f379297bafcb5d563fe26 (MD5) Salm_Eric.doc: 6871552 bytes, checksum: 18825d724b4357db08e4a87e8537555e (MD5) license.txt: 4057 bytes, checksum: 8267f5a262eb2887cb9c9bab8a391a40 (MD5)","Restriction data tranferred 2014-07-01T11:39:47-05:00 Original Data Group with Access Administrator Release Date: 2016-05-30 12:21:23 UTC Reason: Author requested closed access (OA after 2yrs) in Vireo ETD system","Item marked as restricted to the 'Administrator' Group (id=1) by Seth Robbins (robbins.sd@gmail.com) on 2014-05-30T17:21:40Z Item is restricted until 2016-05-30T17:21:23Z","Limited Restriction Lifted for Item 49878 on 2016-09-22T20:59:16Z."]},{"key":"dc:title","label":"Title","values":["Transistor-based biosensing: expanding the functionality of field effect transistors"]}]}],"canonical_facts":{"dc:contributor":["Bashir, Rashid","Alam, Muhammad A.","Cunningham, Brian T.","Liu, Gang Logan"],"dc:creator":["Salm, Eric"],"dc:date":["2014-05-30T17:19:50Z","2016-09-22T20:59:16Z","2014-05"],"dc:description":["Since the invention of Polymerase Chain Reaction (PCR)-based amplification of nucleic acids by Kary Mullis in 1983(1), researchers have spent significant efforts to improve the sensitivity and selectivity of PCR assay and have dramatically enhanced its application(2). PCR is now an integral tool of modern biotechnology processes and biological identification. Due to the growing demands for on-site, rapid diagnosis, attention has been paid in realizing portable, fast, and low cost PCR machines. Through expanding the uses of the field effect transistor platform to include a novel design of heating/cooling, ultra-localized cell lysis, and electrical detection of nucleic acid amplification using an on-chip electrode, this thesis aims to enable the next generation of portable biosensors for primary care and on-site diagnostics. Chapter 2 presents an overview of the current state-of-the-art of electrical biosensors. In keeping with the goal of complete, integrated systems, methods for both sample preparation and detection were evaluated. Electrical sample preparation methods provide a unique opportunity to utilize electrical fields for cell lysis, concentration, and sample flow without the need for additional moving parts or reagents. Electrical detection methods offer a means of reducing reagents by eliminating the need for optical labels. Together, electrical sample preparation and detection will aid the development of portable, low-cost integrated biosensors. Chapters 3 and 4 look at utilizing transistors as platform for sample preparation and manipulation through DNA denaturation and cell lysis. Through application of a 10MHz, AC field between the shorted source-drain and the back-gate of the chip, fringing electric fields located just above the transistor surface are generated. These fringing electric fields can be used for dielectric relaxation of water molecules to generate heat for DNA denaturation as discussed in chapter 3, or to generate a transmembrane potential across a cellular membrane for ultra-localized cell lysis as discussed in chapter 4. These methods expand the functionality of the transistor platform by extending their uses into the realm of sample manipulation. Since the development of ISFETs for biosensing applications, transistors have been used for detection of biological analytes. Chapter 5 extends this functionality to electrical detection of nucleic acid amplification with an on-chip quasi-reference electrode. This method eliminates the need for a bulky/difficult to fabricate reference electrode and enables parallel detection of a large array of individual nucleic acid amplification reaction volumes. This method promises to reduce cost of PCR assays by eliminating optical components as well as improve the portability of the equipment by localizing the detection element to a disposable chip. As discussed in the future outlook presented in chapter 6, the silicon CMOS compatible technologies introduced can be made portable, rapidly heat and cool reaction volumes, and remain inexpensive so the ultimate vision of an array of PCR reaction chambers, where the target sample can be interrogated against an array of primers, can be realized. This thesis has added three new functionalities to the transistor platform. 1) Rapid DNA denaturation 2) Localized single cell lysis and 3) Electrical detection of amplification by-products with an on-chip electrode.","Item withdrawn by Laura Spradlin (lspradl2@illinois.edu) on 2014-02-11T21:23:55Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 3 14_01_27 Eric Salm Thesis.pdf: 9586621 bytes, checksum: e65784d99a421bb69c6e3ecb86275db6 (MD5) Salm_Eric.doc: 6871552 bytes, checksum: 18825d724b4357db08e4a87e8537555e (MD5) Salm_Eric.pdf: 9586621 bytes, checksum: e65784d99a421bb69c6e3ecb86275db6 (MD5)","Made available in DSpace on 2014-05-30T17:19:50Z (GMT). No. of bitstreams: 3 Eric_Salm.pdf: 3037278 bytes, checksum: eff4c448d43f379297bafcb5d563fe26 (MD5) Salm_Eric.doc: 6871552 bytes, checksum: 18825d724b4357db08e4a87e8537555e (MD5) license.txt: 4057 bytes, checksum: 8267f5a262eb2887cb9c9bab8a391a40 (MD5)","Restriction data tranferred 2014-07-01T11:39:47-05:00 Original Data Group with Access Administrator Release Date: 2016-05-30 12:21:23 UTC Reason: Author requested closed access (OA after 2yrs) in Vireo ETD system","Item marked as restricted to the 'Administrator' Group (id=1) by Seth Robbins (robbins.sd@gmail.com) on 2014-05-30T17:21:40Z Item is restricted until 2016-05-30T17:21:23Z","Limited Restriction Lifted for Item 49878 on 2016-09-22T20:59:16Z."],"dc:identifier":["http://hdl.handle.net/2142/49827"],"dc:language":["en"],"dc:rights":["Copyright 2014 Eric Salm"],"dc:subject":["Electrical biosensor","ion-sensitive field-effect transistor (ISFET)","Field Effect Transistor (FET)","reference field-effect transistor (REFET)","solid-state electrode","nucleic acid amplification","Loop-mediated isothermal amplification (LAMP)","Polymerase chain reaction (PCR)","single cell lysis","droplet","DNA denaturation"],"dc:title":["Transistor-based biosensing: expanding the functionality of field effect transistors"],"dc:type":["text"],"thesis:degree_discipline":["Bioengineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:40Z"}