{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/46640"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/46640","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Smart-grid-enabled distributed reactive power support with conservation of voltage reduction","abstract":"As solar energy continues to increase in the current power grid, the reactive power support capability from photovoltaic grid-tie inverters may be used to regulate feeder voltage and reduce system losses on medium- and low-voltage distribution systems. The focus of this thesis is to develop a smart-grid-enabled control algorithm that will determine the amount of reactive power injection or absorption required at each node to minimize the deviation from the control voltage level. Once the voltage level is achieved, implementing conservation of voltage reduction (CVR) further benefits the system by increasing energy savings. Generally, reactive power support occurs at the substation level, whereas with the communication advantages and system feedback provided by smart-grid devices such as residential smart meters, it facilitates an extensive reactive power support scheme that reaches all the way to the end-users. The method is tested on a modified IEEE 13 node feeder system assuming piecewise steady state operating conditions, full knowledge of the system states, and two-way communication between the control center and the end-users in the distribution systems. The control algorithms are modeled in MATLAB and the simulations are performed in OpenDSS using the same system to validate the results.","abstract_html":"As solar energy continues to increase in the current power grid, the reactive power support capability from photovoltaic grid-tie inverters may be used to regulate feeder voltage and reduce system losses on medium- and low-voltage distribution systems. The focus of this thesis is to develop a smart-grid-enabled control algorithm that will determine the amount of reactive power injection or absorption required at each node to minimize the deviation from the control voltage level. Once the voltage level is achieved, implementing conservation of voltage reduction (CVR) further benefits the system by increasing energy savings. Generally, reactive power support occurs at the substation level, whereas with the communication advantages and system feedback provided by smart-grid devices such as residential smart meters, it facilitates an extensive reactive power support scheme that reaches all the way to the end-users. The method is tested on a modified IEEE 13 node feeder system assuming piecewise steady state operating conditions, full knowledge of the system states, and two-way communication between the control center and the end-users in the distribution systems. The control algorithms are modeled in MATLAB and the simulations are performed in OpenDSS using the same system to validate the results.","abstract_has_math":false,"creators":["Liu, Hao Jan"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engr","degree_department":null,"school":null,"contributors":["Overbye, Thomas J."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-01-16T17:57:09Z","date_published":"2014-01-16T17:57:09Z","updated_at":"2026-07-22T22:25:36Z","subjects":["Photovoltaic (PV) systems","distributed power generation","reactive power support","voltage control","conservation of voltage reduction (CVR)","Open Distribution System Simulator (OpenDSS)","distributed control","distribution network."],"languages":["en"],"rights":["Copyright 2013 Hao Jan Liu"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/46640","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Overbye, Thomas J."]},{"key":"dc:creator","label":"Author","values":["Liu, Hao Jan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-01-16T17:57:09Z","2013-12"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Photovoltaic (PV) systems","distributed power generation","reactive power support","voltage control","conservation of voltage reduction (CVR)","Open Distribution System Simulator (OpenDSS)","distributed control","distribution network."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2013 Hao Jan Liu"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/46640"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["As solar energy continues to increase in the current power grid, the reactive power support capability from photovoltaic grid-tie inverters may be used to regulate feeder voltage and reduce system losses on medium- and low-voltage distribution systems. The focus of this thesis is to develop a smart-grid-enabled control algorithm that will determine the amount of reactive power injection or absorption required at each node to minimize the deviation from the control voltage level. Once the voltage level is achieved, implementing conservation of voltage reduction (CVR) further benefits the system by increasing energy savings. Generally, reactive power support occurs at the substation level, whereas with the communication advantages and system feedback provided by smart-grid devices such as residential smart meters, it facilitates an extensive reactive power support scheme that reaches all the way to the end-users. The method is tested on a modified IEEE 13 node feeder system assuming piecewise steady state operating conditions, full knowledge of the system states, and two-way communication between the control center and the end-users in the distribution systems. The control algorithms are modeled in MATLAB and the simulations are performed in OpenDSS using the same system to validate the results.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2013-12-06T14:38:39Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 8 references.bib: 41909 bytes, checksum: 50fd507453ee997e77832a1f01af08a4 (MD5) Thesis Main.lyx: 13006 bytes, checksum: 13aa5bf8e7f2058a545b64ae6aa8e478 (MD5) Chap5.lyx: 4011 bytes, checksum: 99a6c15b5c13d5ba079a6be9a7e937ec (MD5) Chap4.lyx: 49463 bytes, checksum: 67452b853e2575cf17b006571a8f3bb5 (MD5) Chap3.lyx: 79969 bytes, checksum: d819b790029f5dc7ee5e47f678a07a14 (MD5) Chap2.lyx: 23375 bytes, checksum: 886edc7955e8b7b1aec0b65911ec984e (MD5) Chap1.lyx: 7802 bytes, checksum: 9e12da5b06847bf76223a60a23fd946c (MD5) Liu_HaoJan.pdf.pdf: 1210034 bytes, checksum: 010df4c0371fb1dc0666c4cf90db8973 (MD5)","Made available in DSpace on 2014-01-16T17:57:09Z (GMT). No. of bitstreams: 9 Hao Jan_Liu.pdf: 1210034 bytes, checksum: 010df4c0371fb1dc0666c4cf90db8973 (MD5) references.bib: 41909 bytes, checksum: 50fd507453ee997e77832a1f01af08a4 (MD5) Thesis Main.lyx: 13006 bytes, checksum: 13aa5bf8e7f2058a545b64ae6aa8e478 (MD5) Chap5.lyx: 4011 bytes, checksum: 99a6c15b5c13d5ba079a6be9a7e937ec (MD5) Chap4.lyx: 49463 bytes, checksum: 67452b853e2575cf17b006571a8f3bb5 (MD5) Chap3.lyx: 79969 bytes, checksum: d819b790029f5dc7ee5e47f678a07a14 (MD5) Chap2.lyx: 23375 bytes, checksum: 886edc7955e8b7b1aec0b65911ec984e (MD5) Chap1.lyx: 7802 bytes, checksum: 9e12da5b06847bf76223a60a23fd946c (MD5) license.txt: 4060 bytes, checksum: ef5669510e832863356eb88138547bad (MD5)"]},{"key":"dc:title","label":"Title","values":["Smart-grid-enabled distributed reactive power support with conservation of voltage reduction"]}]}],"canonical_facts":{"dc:contributor":["Overbye, Thomas J."],"dc:creator":["Liu, Hao Jan"],"dc:date":["2014-01-16T17:57:09Z","2013-12"],"dc:description":["As solar energy continues to increase in the current power grid, the reactive power support capability from photovoltaic grid-tie inverters may be used to regulate feeder voltage and reduce system losses on medium- and low-voltage distribution systems. The focus of this thesis is to develop a smart-grid-enabled control algorithm that will determine the amount of reactive power injection or absorption required at each node to minimize the deviation from the control voltage level. Once the voltage level is achieved, implementing conservation of voltage reduction (CVR) further benefits the system by increasing energy savings. Generally, reactive power support occurs at the substation level, whereas with the communication advantages and system feedback provided by smart-grid devices such as residential smart meters, it facilitates an extensive reactive power support scheme that reaches all the way to the end-users. The method is tested on a modified IEEE 13 node feeder system assuming piecewise steady state operating conditions, full knowledge of the system states, and two-way communication between the control center and the end-users in the distribution systems. The control algorithms are modeled in MATLAB and the simulations are performed in OpenDSS using the same system to validate the results.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2013-12-06T14:38:39Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 8 references.bib: 41909 bytes, checksum: 50fd507453ee997e77832a1f01af08a4 (MD5) Thesis Main.lyx: 13006 bytes, checksum: 13aa5bf8e7f2058a545b64ae6aa8e478 (MD5) Chap5.lyx: 4011 bytes, checksum: 99a6c15b5c13d5ba079a6be9a7e937ec (MD5) Chap4.lyx: 49463 bytes, checksum: 67452b853e2575cf17b006571a8f3bb5 (MD5) Chap3.lyx: 79969 bytes, checksum: d819b790029f5dc7ee5e47f678a07a14 (MD5) Chap2.lyx: 23375 bytes, checksum: 886edc7955e8b7b1aec0b65911ec984e (MD5) Chap1.lyx: 7802 bytes, checksum: 9e12da5b06847bf76223a60a23fd946c (MD5) Liu_HaoJan.pdf.pdf: 1210034 bytes, checksum: 010df4c0371fb1dc0666c4cf90db8973 (MD5)","Made available in DSpace on 2014-01-16T17:57:09Z (GMT). No. of bitstreams: 9 Hao Jan_Liu.pdf: 1210034 bytes, checksum: 010df4c0371fb1dc0666c4cf90db8973 (MD5) references.bib: 41909 bytes, checksum: 50fd507453ee997e77832a1f01af08a4 (MD5) Thesis Main.lyx: 13006 bytes, checksum: 13aa5bf8e7f2058a545b64ae6aa8e478 (MD5) Chap5.lyx: 4011 bytes, checksum: 99a6c15b5c13d5ba079a6be9a7e937ec (MD5) Chap4.lyx: 49463 bytes, checksum: 67452b853e2575cf17b006571a8f3bb5 (MD5) Chap3.lyx: 79969 bytes, checksum: d819b790029f5dc7ee5e47f678a07a14 (MD5) Chap2.lyx: 23375 bytes, checksum: 886edc7955e8b7b1aec0b65911ec984e (MD5) Chap1.lyx: 7802 bytes, checksum: 9e12da5b06847bf76223a60a23fd946c (MD5) license.txt: 4060 bytes, checksum: ef5669510e832863356eb88138547bad (MD5)"],"dc:identifier":["http://hdl.handle.net/2142/46640"],"dc:language":["en"],"dc:rights":["Copyright 2013 Hao Jan Liu"],"dc:subject":["Photovoltaic (PV) systems","distributed power generation","reactive power support","voltage control","conservation of voltage reduction (CVR)","Open Distribution System Simulator (OpenDSS)","distributed control","distribution network."],"dc:title":["Smart-grid-enabled distributed reactive power support with conservation of voltage reduction"],"dc:type":["text"],"thesis:degree_discipline":["Electrical & Computer Engr"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:36Z"}