{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/46621"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/46621","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Nanoscale magnetic resonance imaging using silicon nanowire oscillators","abstract":"This dissertation describes new techniques for nanometer-scale magnetic resonance imaging. We report methods that enable the use of (1) silicon nanowires as ultrasensitive force transducers for magnetic resonance detection and (2) pulsed magnetic resonance techniques for nanometer-scale imaging and spectroscopy. Because of their small size and high aspect ratio, silicon nanowires have inherently low mechanical dissipation and correspondingly low thermal force noise. We have developed a method for displacement detection of silicon nanowire oscillators using a polarized fiber-optic interferometer. Even though the nanowires have widths much smaller than optical wavelengths, interferometry enables sensitive displacement detection because the nanowires exhibit enhanced optical scattering when the incident polarization is parallel to the nanowire axis. Interferometry also allows us to implement active feedback control of nanowire oscillators. To perform magnetic resonance detection using the nanowires, we have developed a technique, which uses electric currents through a nanoscale metal constriction to generate time-dependent magnetic field gradients to couple nuclear spins in a sample to the resonant displacement of the nanowire oscillator. The ability to generate time-dependent fields and gradients together with a new spin noise encoding protocol enable us to use pulsed magnetic resonance techniques for nanometer-scale samples. We demonstrate Fourier transform magnetic resonance imaging and spectroscopy of a statistically polarized polystyrene sample with roughly 10-nm spatial resolution.","abstract_html":"This dissertation describes new techniques for nanometer-scale magnetic resonance imaging. We report methods that enable the use of (1) silicon nanowires as ultrasensitive force transducers for magnetic resonance detection and (2) pulsed magnetic resonance techniques for nanometer-scale imaging and spectroscopy. Because of their small size and high aspect ratio, silicon nanowires have inherently low mechanical dissipation and correspondingly low thermal force noise. We have developed a method for displacement detection of silicon nanowire oscillators using a polarized fiber-optic interferometer. Even though the nanowires have widths much smaller than optical wavelengths, interferometry enables sensitive displacement detection because the nanowires exhibit enhanced optical scattering when the incident polarization is parallel to the nanowire axis. Interferometry also allows us to implement active feedback control of nanowire oscillators. To perform magnetic resonance detection using the nanowires, we have developed a technique, which uses electric currents through a nanoscale metal constriction to generate time-dependent magnetic field gradients to couple nuclear spins in a sample to the resonant displacement of the nanowire oscillator. The ability to generate time-dependent fields and gradients together with a new spin noise encoding protocol enable us to use pulsed magnetic resonance techniques for nanometer-scale samples. We demonstrate Fourier transform magnetic resonance imaging and spectroscopy of a statistically polarized polystyrene sample with roughly 10-nm spatial resolution.","abstract_has_math":false,"creators":["Nichol, John"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Physics","degree_department":null,"school":null,"contributors":["Budakian, Raffi","Cooper, S. Lance","DeMarco, Brian L.","Stone, Michael"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-01-16T17:56:29Z","date_published":"2014-01-16T17:56:29Z","updated_at":"2026-07-22T22:25:36Z","subjects":["magnetic resonance imaging","silicon nanowire","scanning probe microscopy"],"languages":["en"],"rights":["Copyright 2013 John M. Nichol"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/46621","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Budakian, Raffi","Cooper, S. Lance","DeMarco, Brian L.","Stone, Michael"]},{"key":"dc:creator","label":"Author","values":["Nichol, John"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-01-16T17:56:29Z","2013-12"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["magnetic resonance imaging","silicon nanowire","scanning probe microscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2013 John M. Nichol"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/46621"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This dissertation describes new techniques for nanometer-scale magnetic resonance imaging. We report methods that enable the use of (1) silicon nanowires as ultrasensitive force transducers for magnetic resonance detection and (2) pulsed magnetic resonance techniques for nanometer-scale imaging and spectroscopy. Because of their small size and high aspect ratio, silicon nanowires have inherently low mechanical dissipation and correspondingly low thermal force noise. We have developed a method for displacement detection of silicon nanowire oscillators using a polarized fiber-optic interferometer. Even though the nanowires have widths much smaller than optical wavelengths, interferometry enables sensitive displacement detection because the nanowires exhibit enhanced optical scattering when the incident polarization is parallel to the nanowire axis. Interferometry also allows us to implement active feedback control of nanowire oscillators. To perform magnetic resonance detection using the nanowires, we have developed a technique, which uses electric currents through a nanoscale metal constriction to generate time-dependent magnetic field gradients to couple nuclear spins in a sample to the resonant displacement of the nanowire oscillator. The ability to generate time-dependent fields and gradients together with a new spin noise encoding protocol enable us to use pulsed magnetic resonance techniques for nanometer-scale samples. We demonstrate Fourier transform magnetic resonance imaging and spectroscopy of a statistically polarized polystyrene sample with roughly 10-nm spatial resolution.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2013-07-24T21:20:48Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Nichol_John.pdf: 5598838 bytes, checksum: 93078a3922b957b266d73208412b138e (MD5)","Made available in DSpace on 2014-01-16T17:56:29Z (GMT). No. of bitstreams: 2 John_Nichol.pdf: 5598832 bytes, checksum: 73ee2ce72f7f4e6ef452a4ee73520a20 (MD5) license.txt: 4060 bytes, checksum: 2947f46c479ac6df9ed57f0223249b45 (MD5)"]},{"key":"dc:title","label":"Title","values":["Nanoscale magnetic resonance imaging using silicon nanowire oscillators"]}]}],"canonical_facts":{"dc:contributor":["Budakian, Raffi","Cooper, S. Lance","DeMarco, Brian L.","Stone, Michael"],"dc:creator":["Nichol, John"],"dc:date":["2014-01-16T17:56:29Z","2013-12"],"dc:description":["This dissertation describes new techniques for nanometer-scale magnetic resonance imaging. We report methods that enable the use of (1) silicon nanowires as ultrasensitive force transducers for magnetic resonance detection and (2) pulsed magnetic resonance techniques for nanometer-scale imaging and spectroscopy. Because of their small size and high aspect ratio, silicon nanowires have inherently low mechanical dissipation and correspondingly low thermal force noise. We have developed a method for displacement detection of silicon nanowire oscillators using a polarized fiber-optic interferometer. Even though the nanowires have widths much smaller than optical wavelengths, interferometry enables sensitive displacement detection because the nanowires exhibit enhanced optical scattering when the incident polarization is parallel to the nanowire axis. Interferometry also allows us to implement active feedback control of nanowire oscillators. To perform magnetic resonance detection using the nanowires, we have developed a technique, which uses electric currents through a nanoscale metal constriction to generate time-dependent magnetic field gradients to couple nuclear spins in a sample to the resonant displacement of the nanowire oscillator. The ability to generate time-dependent fields and gradients together with a new spin noise encoding protocol enable us to use pulsed magnetic resonance techniques for nanometer-scale samples. We demonstrate Fourier transform magnetic resonance imaging and spectroscopy of a statistically polarized polystyrene sample with roughly 10-nm spatial resolution.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2013-07-24T21:20:48Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Nichol_John.pdf: 5598838 bytes, checksum: 93078a3922b957b266d73208412b138e (MD5)","Made available in DSpace on 2014-01-16T17:56:29Z (GMT). No. of bitstreams: 2 John_Nichol.pdf: 5598832 bytes, checksum: 73ee2ce72f7f4e6ef452a4ee73520a20 (MD5) license.txt: 4060 bytes, checksum: 2947f46c479ac6df9ed57f0223249b45 (MD5)"],"dc:identifier":["http://hdl.handle.net/2142/46621"],"dc:language":["en"],"dc:rights":["Copyright 2013 John M. Nichol"],"dc:subject":["magnetic resonance imaging","silicon nanowire","scanning probe microscopy"],"dc:title":["Nanoscale magnetic resonance imaging using silicon nanowire oscillators"],"dc:type":["text"],"thesis:degree_discipline":["Physics"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:36Z"}