{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/45690"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/45690","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Design and performance of a prototype borohydride fuel cell and control system","abstract":"A direct borohydride fuel cell stack with a novel integrated manifold, along with a control system, was designed, manufactured and studied. Two fuel cell stacks were built and demonstrated. The main objective was to build these stacks to achieve a power level of 100 watts. The control system was designed to allow for fuel cell startup and to self-sustain the stack. One 12 cell stack was able to achieve 168 Watts at 14 W/cell or 140 mW/cm2, with the second 9 cell stack only able to achieve 5.6 W/cell , 56 mW/cm2, or 54 W. A design flaw was encountered which did not allow for extended operation of the stack. A quick “fix” solution to this problem was attempted in the second stack. The solution, however, introduced several new issues which resulted in degraded performance. Nevertheless, the control system showed the cell stack can operate independently. This study has provided valuable information about the cell stack and control system performance which will be extremely helpful in future designs.","abstract_html":"A direct borohydride fuel cell stack with a novel integrated manifold, along with a control system, was designed, manufactured and studied. Two fuel cell stacks were built and demonstrated. The main objective was to build these stacks to achieve a power level of 100 watts. The control system was designed to allow for fuel cell startup and to self-sustain the stack. One 12 cell stack was able to achieve 168 Watts at 14 W/cell or 140 mW/cm2, with the second 9 cell stack only able to achieve 5.6 W/cell , 56 mW/cm2, or 54 W. A design flaw was encountered which did not allow for extended operation of the stack. A quick “fix” solution to this problem was attempted in the second stack. The solution, however, introduced several new issues which resulted in degraded performance. Nevertheless, the control system showed the cell stack can operate independently. This study has provided valuable information about the cell stack and control system performance which will be extremely helpful in future designs.","abstract_has_math":false,"creators":["Patel, Tapan"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Miley, George H."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-05-24T22:14:58Z","date_published":"2013-05-24T22:14:58Z","updated_at":"2026-07-22T22:25:36Z","subjects":["Fuel cell","Sodium Borohydride","Hydrogen Peroxide","Control System"],"languages":["en"],"rights":["Copyright 2012 Tapan Patel"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/45690","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Miley, George H."]},{"key":"dc:creator","label":"Author","values":["Patel, Tapan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-05-24T22:14:58Z","2013-08-30T16:46:49Z","2015-08-30T10:01:39Z","2012-05"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fuel cell","Sodium Borohydride","Hydrogen Peroxide","Control System"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2012 Tapan Patel"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/45690"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A direct borohydride fuel cell stack with a novel integrated manifold, along with a control system, was designed, manufactured and studied. Two fuel cell stacks were built and demonstrated. The main objective was to build these stacks to achieve a power level of 100 watts. The control system was designed to allow for fuel cell startup and to self-sustain the stack. One 12 cell stack was able to achieve 168 Watts at 14 W/cell or 140 mW/cm2, with the second 9 cell stack only able to achieve 5.6 W/cell , 56 mW/cm2, or 54 W. A design flaw was encountered which did not allow for extended operation of the stack. A quick “fix” solution to this problem was attempted in the second stack. The solution, however, introduced several new issues which resulted in degraded performance. Nevertheless, the control system showed the cell stack can operate independently. This study has provided valuable information about the cell stack and control system performance which will be extremely helpful in future designs.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-04-23T15:13:14Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Patel_Tapan.pdf: 2276650 bytes, checksum: 4f9572a39c7d5ae9a9eebe233de03193 (MD5)","Made available in DSpace on 2013-05-24T22:14:58Z (GMT). No. of bitstreams: 2 Tapan_Patel.pdf: 2301606 bytes, checksum: 0d9bcc9a791545a1b40eed4e979d2f83 (MD5) license.txt: 4061 bytes, checksum: ebe9f66a0ee82b69c56606471e982ffd (MD5)","Restriction data tranferred 2014-07-01T11:11:22-05:00 Original Data Group with Access UIUC Users [automated] Release Date: 2015-08-30 11:47:05 UTC Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Seth Robbins (srobbins@illinois.edu) on 2013-05-24T22:18:34Z Item is restricted until 2015-05-24T22:18:31Z","Made available in DSpace on 2013-08-30T16:46:49Z (GMT). No. of bitstreams: 2 license.txt: 4061 bytes, checksum: ebe9f66a0ee82b69c56606471e982ffd (MD5) Tapan_Patel.pdf: 2301606 bytes, checksum: 0d9bcc9a791545a1b40eed4e979d2f83 (MD5) Previous issue date: 2013-05-24T22:14:58Z","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Seth Robbins (srobbins@illinois.edu) on 2013-08-30T16:47:05Z Item is restricted until 2015-08-30T16:47:05Z","U of I Only Restriction Lifted for Item 45668 on 2015-08-30T10:01:39Z."]},{"key":"dc:title","label":"Title","values":["Design and performance of a prototype borohydride fuel cell and control system"]}]}],"canonical_facts":{"dc:contributor":["Miley, George H."],"dc:creator":["Patel, Tapan"],"dc:date":["2013-05-24T22:14:58Z","2013-08-30T16:46:49Z","2015-08-30T10:01:39Z","2012-05"],"dc:description":["A direct borohydride fuel cell stack with a novel integrated manifold, along with a control system, was designed, manufactured and studied. Two fuel cell stacks were built and demonstrated. The main objective was to build these stacks to achieve a power level of 100 watts. The control system was designed to allow for fuel cell startup and to self-sustain the stack. One 12 cell stack was able to achieve 168 Watts at 14 W/cell or 140 mW/cm2, with the second 9 cell stack only able to achieve 5.6 W/cell , 56 mW/cm2, or 54 W. A design flaw was encountered which did not allow for extended operation of the stack. A quick “fix” solution to this problem was attempted in the second stack. The solution, however, introduced several new issues which resulted in degraded performance. Nevertheless, the control system showed the cell stack can operate independently. This study has provided valuable information about the cell stack and control system performance which will be extremely helpful in future designs.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-04-23T15:13:14Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Patel_Tapan.pdf: 2276650 bytes, checksum: 4f9572a39c7d5ae9a9eebe233de03193 (MD5)","Made available in DSpace on 2013-05-24T22:14:58Z (GMT). No. of bitstreams: 2 Tapan_Patel.pdf: 2301606 bytes, checksum: 0d9bcc9a791545a1b40eed4e979d2f83 (MD5) license.txt: 4061 bytes, checksum: ebe9f66a0ee82b69c56606471e982ffd (MD5)","Restriction data tranferred 2014-07-01T11:11:22-05:00 Original Data Group with Access UIUC Users [automated] Release Date: 2015-08-30 11:47:05 UTC Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Seth Robbins (srobbins@illinois.edu) on 2013-05-24T22:18:34Z Item is restricted until 2015-05-24T22:18:31Z","Made available in DSpace on 2013-08-30T16:46:49Z (GMT). No. of bitstreams: 2 license.txt: 4061 bytes, checksum: ebe9f66a0ee82b69c56606471e982ffd (MD5) Tapan_Patel.pdf: 2301606 bytes, checksum: 0d9bcc9a791545a1b40eed4e979d2f83 (MD5) Previous issue date: 2013-05-24T22:14:58Z","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Seth Robbins (srobbins@illinois.edu) on 2013-08-30T16:47:05Z Item is restricted until 2015-08-30T16:47:05Z","U of I Only Restriction Lifted for Item 45668 on 2015-08-30T10:01:39Z."],"dc:identifier":["http://hdl.handle.net/2142/45690"],"dc:language":["en"],"dc:rights":["Copyright 2012 Tapan Patel"],"dc:subject":["Fuel cell","Sodium Borohydride","Hydrogen Peroxide","Control System"],"dc:title":["Design and performance of a prototype borohydride fuel cell and control system"],"dc:type":["text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:36Z"}