{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/44103"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/44103","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Phase derivative microscopy of biological cells and tissues","abstract":"Phase derivative microscopy (PDM), including Laplace field microscopy (LFM) and gradient field microscopy (GFM), generates high contrast images of transparent specimens. These methods utilize spatial light modulation at the Fourier plane of a bright field microscope to optically obtain the derivatives of the phase and increase the contrast of the final image. The controllable spatial modulation pattern allows obtaining both the first-order and the second-order derivative of the phase. Compared to differential interference contrast (DIC) microscopy, which is a traditional method of imaging the derivative of the phase, PDM shows higher stability because there are no mechanically moving parts involved in the operation. More importantly, unlike DIC, PDM does not use polarizing optics and, thus, it is applicable to birefringent samples. Furthermore, because it is a single-shot technique, PDM allows acquisition speed as fast as the detector allows, and therefore, it is suitable for studying live biological samples. This thesis introduces the principle of PDM, the setup, and also applications of PDM, including high contrast imaging, live cell dynamics study, and unstained tissue biopsies.","abstract_html":"Phase derivative microscopy (PDM), including Laplace field microscopy (LFM) and gradient field microscopy (GFM), generates high contrast images of transparent specimens. These methods utilize spatial light modulation at the Fourier plane of a bright field microscope to optically obtain the derivatives of the phase and increase the contrast of the final image. The controllable spatial modulation pattern allows obtaining both the first-order and the second-order derivative of the phase. Compared to differential interference contrast (DIC) microscopy, which is a traditional method of imaging the derivative of the phase, PDM shows higher stability because there are no mechanically moving parts involved in the operation. More importantly, unlike DIC, PDM does not use polarizing optics and, thus, it is applicable to birefringent samples. Furthermore, because it is a single-shot technique, PDM allows acquisition speed as fast as the detector allows, and therefore, it is suitable for studying live biological samples. This thesis introduces the principle of PDM, the setup, and also applications of PDM, including high contrast imaging, live cell dynamics study, and unstained tissue biopsies.","abstract_has_math":false,"creators":["Kim, Tae Woo"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engr","degree_department":null,"school":null,"contributors":["Popescu, Gabriel"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-05-24T21:50:48Z","date_published":"2013-05-24T21:50:48Z","updated_at":"2026-07-22T22:25:33Z","subjects":["Microscopy","Cell analysis","Coherence Imaging","Optical pathology","Tissue characterization"],"languages":["en"],"rights":["Copyright 2013 Tae Woo Kim"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/44103","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Popescu, Gabriel"]},{"key":"dc:creator","label":"Author","values":["Kim, Tae Woo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-05-24T21:50:48Z","2013-05"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microscopy","Cell analysis","Coherence Imaging","Optical pathology","Tissue characterization"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2013 Tae Woo Kim"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/44103"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Phase derivative microscopy (PDM), including Laplace field microscopy (LFM) and gradient field microscopy (GFM), generates high contrast images of transparent specimens. These methods utilize spatial light modulation at the Fourier plane of a bright field microscope to optically obtain the derivatives of the phase and increase the contrast of the final image. The controllable spatial modulation pattern allows obtaining both the first-order and the second-order derivative of the phase. Compared to differential interference contrast (DIC) microscopy, which is a traditional method of imaging the derivative of the phase, PDM shows higher stability because there are no mechanically moving parts involved in the operation. More importantly, unlike DIC, PDM does not use polarizing optics and, thus, it is applicable to birefringent samples. Furthermore, because it is a single-shot technique, PDM allows acquisition speed as fast as the detector allows, and therefore, it is suitable for studying live biological samples. This thesis introduces the principle of PDM, the setup, and also applications of PDM, including high contrast imaging, live cell dynamics study, and unstained tissue biopsies.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2013-04-24T17:35:41Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Kim_Tae Woo.pdf: 1983516 bytes, checksum: 246cc886fb340112112ff6546ded7bb7 (MD5)","Made available in DSpace on 2013-05-24T21:50:48Z (GMT). No. of bitstreams: 2 Tae Woo_Kim.pdf: 1983516 bytes, checksum: 246cc886fb340112112ff6546ded7bb7 (MD5) license.txt: 4059 bytes, checksum: cdbc8dff75dac08bb6950a7c1cc76250 (MD5)"]},{"key":"dc:title","label":"Title","values":["Phase derivative microscopy of biological cells and tissues"]}]}],"canonical_facts":{"dc:contributor":["Popescu, Gabriel"],"dc:creator":["Kim, Tae Woo"],"dc:date":["2013-05-24T21:50:48Z","2013-05"],"dc:description":["Phase derivative microscopy (PDM), including Laplace field microscopy (LFM) and gradient field microscopy (GFM), generates high contrast images of transparent specimens. These methods utilize spatial light modulation at the Fourier plane of a bright field microscope to optically obtain the derivatives of the phase and increase the contrast of the final image. The controllable spatial modulation pattern allows obtaining both the first-order and the second-order derivative of the phase. Compared to differential interference contrast (DIC) microscopy, which is a traditional method of imaging the derivative of the phase, PDM shows higher stability because there are no mechanically moving parts involved in the operation. More importantly, unlike DIC, PDM does not use polarizing optics and, thus, it is applicable to birefringent samples. Furthermore, because it is a single-shot technique, PDM allows acquisition speed as fast as the detector allows, and therefore, it is suitable for studying live biological samples. This thesis introduces the principle of PDM, the setup, and also applications of PDM, including high contrast imaging, live cell dynamics study, and unstained tissue biopsies.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2013-04-24T17:35:41Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Kim_Tae Woo.pdf: 1983516 bytes, checksum: 246cc886fb340112112ff6546ded7bb7 (MD5)","Made available in DSpace on 2013-05-24T21:50:48Z (GMT). No. of bitstreams: 2 Tae Woo_Kim.pdf: 1983516 bytes, checksum: 246cc886fb340112112ff6546ded7bb7 (MD5) license.txt: 4059 bytes, checksum: cdbc8dff75dac08bb6950a7c1cc76250 (MD5)"],"dc:identifier":["http://hdl.handle.net/2142/44103"],"dc:language":["en"],"dc:rights":["Copyright 2013 Tae Woo Kim"],"dc:subject":["Microscopy","Cell analysis","Coherence Imaging","Optical pathology","Tissue characterization"],"dc:title":["Phase derivative microscopy of biological cells and tissues"],"dc:type":["text"],"thesis:degree_discipline":["Electrical & Computer Engr"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:33Z"}