{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/42337"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/42337","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Analytical and experimental investigation of two-phase ejector cycles using low-pressure refrigerants","abstract":"The standard two-phase ejector cycle has received significant attention in research studies in recent years because of its ability to improve the efficiency of refrigeration cycles. However, there are several alternate two-phase ejector cycles that have been proposed but have received little attention in two-phase ejector studies. Unlike the standard two-phase ejector cycle, these alternate ejector cycles offer the opportunity for evaporation at multiple temperatures, and they do not require a liquid-vapor separator, the inefficiency of which can decrease the performance of the standard two-phase ejector cycle. Furthermore, it can be shown that the alternate ejector cycles offer potential advantages in terms of real applications without reducing the theoretical COP, compared to the standard two-phase ejector cycle, warranting further research on alternate two-phase ejector cycles. An alternate two-phase ejector cycle was constructed and used to evaluate ejector performance and cycle performance improvement when compared to expansion valve cycles. R134a and R1234yf were used as the working fluids in the experimental tests. These lowpressure working fluids offer less improvement potential with ejector cycles because of their lower throttling loss, compared to CO2. It was found that two-phase ejectors using these lowpressure working fluids were able to recover similar but lower fractions of the total expansion work available for recovery, compared to two-phase ejectors using CO2. The alternate ejector cycle was compared to an expansion valve cycle with two evaporation temperatures in order to match the cooling capacity in each evaporator. In this comparison, R134a showed COP improvements of up to 8 %, and R1234yf showed COP improvements of up to 12 %. The alternate ejector cycle was also compared to an expansion valve cycle with a single evaporation temperature, which may be a more practical means of comparison for many applications. In this case, R134a showed COP improvements of up to 5 %, and R1234yf showed COP improvements of up to 6 %. While not as high as the COP improvements that have been observed for CO2, the low-pressure working fluids R134a and R1234yf certainly offer some noticeable COP improvements on two-phase ejector cycles.","abstract_html":"The standard two-phase ejector cycle has received significant attention in research studies in recent years because of its ability to improve the efficiency of refrigeration cycles. However, there are several alternate two-phase ejector cycles that have been proposed but have received little attention in two-phase ejector studies. Unlike the standard two-phase ejector cycle, these alternate ejector cycles offer the opportunity for evaporation at multiple temperatures, and they do not require a liquid-vapor separator, the inefficiency of which can decrease the performance of the standard two-phase ejector cycle. Furthermore, it can be shown that the alternate ejector cycles offer potential advantages in terms of real applications without reducing the theoretical COP, compared to the standard two-phase ejector cycle, warranting further research on alternate two-phase ejector cycles. An alternate two-phase ejector cycle was constructed and used to evaluate ejector performance and cycle performance improvement when compared to expansion valve cycles. R134a and R1234yf were used as the working fluids in the experimental tests. These lowpressure working fluids offer less improvement potential with ejector cycles because of their lower throttling loss, compared to CO2. It was found that two-phase ejectors using these lowpressure working fluids were able to recover similar but lower fractions of the total expansion work available for recovery, compared to two-phase ejectors using CO2. The alternate ejector cycle was compared to an expansion valve cycle with two evaporation temperatures in order to match the cooling capacity in each evaporator. In this comparison, R134a showed COP improvements of up to 8 %, and R1234yf showed COP improvements of up to 12 %. The alternate ejector cycle was also compared to an expansion valve cycle with a single evaporation temperature, which may be a more practical means of comparison for many applications. In this case, R134a showed COP improvements of up to 5 %, and R1234yf showed COP improvements of up to 6 %. While not as high as the COP improvements that have been observed for CO2, the low-pressure working fluids R134a and R1234yf certainly offer some noticeable COP improvements on two-phase ejector cycles.","abstract_has_math":false,"creators":["Lawrence, Neal"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Hrnjak, Predrag S.","Elbel, Stefan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-02-03T19:35:43Z","date_published":"2013-02-03T19:35:43Z","updated_at":"2026-07-22T22:25:33Z","subjects":["refrigeration","two-phase ejector"],"languages":["en"],"rights":["Copyright 2012 Neal D. Lawrence"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/42337","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hrnjak, Predrag S.","Elbel, Stefan"]},{"key":"dc:creator","label":"Author","values":["Lawrence, Neal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-02-03T19:35:43Z","2012-12"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["refrigeration","two-phase ejector"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2012 Neal D. Lawrence"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/42337"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The standard two-phase ejector cycle has received significant attention in research studies in recent years because of its ability to improve the efficiency of refrigeration cycles. However, there are several alternate two-phase ejector cycles that have been proposed but have received little attention in two-phase ejector studies. Unlike the standard two-phase ejector cycle, these alternate ejector cycles offer the opportunity for evaporation at multiple temperatures, and they do not require a liquid-vapor separator, the inefficiency of which can decrease the performance of the standard two-phase ejector cycle. Furthermore, it can be shown that the alternate ejector cycles offer potential advantages in terms of real applications without reducing the theoretical COP, compared to the standard two-phase ejector cycle, warranting further research on alternate two-phase ejector cycles. An alternate two-phase ejector cycle was constructed and used to evaluate ejector performance and cycle performance improvement when compared to expansion valve cycles. R134a and R1234yf were used as the working fluids in the experimental tests. These lowpressure working fluids offer less improvement potential with ejector cycles because of their lower throttling loss, compared to CO2. It was found that two-phase ejectors using these lowpressure working fluids were able to recover similar but lower fractions of the total expansion work available for recovery, compared to two-phase ejectors using CO2. The alternate ejector cycle was compared to an expansion valve cycle with two evaporation temperatures in order to match the cooling capacity in each evaporator. In this comparison, R134a showed COP improvements of up to 8 %, and R1234yf showed COP improvements of up to 12 %. The alternate ejector cycle was also compared to an expansion valve cycle with a single evaporation temperature, which may be a more practical means of comparison for many applications. In this case, R134a showed COP improvements of up to 5 %, and R1234yf showed COP improvements of up to 6 %. While not as high as the COP improvements that have been observed for CO2, the low-pressure working fluids R134a and R1234yf certainly offer some noticeable COP improvements on two-phase ejector cycles.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-12-12T16:43:45Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Lawrence_Neal.pdf: 2454424 bytes, checksum: 75f15adc2b558b6cc6d0dfdc3e560341 (MD5)","Made available in DSpace on 2013-02-03T19:35:43Z (GMT). No. of bitstreams: 2 Neal_Lawrence.pdf: 2454417 bytes, checksum: ef3941b4c892c40a4e66dffaa89b2f30 (MD5) license.txt: 4063 bytes, checksum: aae0d5f0ccac2bc7876af5e62aa22bf2 (MD5)"]},{"key":"dc:title","label":"Title","values":["Analytical and experimental investigation of two-phase ejector cycles using low-pressure refrigerants"]}]}],"canonical_facts":{"dc:contributor":["Hrnjak, Predrag S.","Elbel, Stefan"],"dc:creator":["Lawrence, Neal"],"dc:date":["2013-02-03T19:35:43Z","2012-12"],"dc:description":["The standard two-phase ejector cycle has received significant attention in research studies in recent years because of its ability to improve the efficiency of refrigeration cycles. However, there are several alternate two-phase ejector cycles that have been proposed but have received little attention in two-phase ejector studies. Unlike the standard two-phase ejector cycle, these alternate ejector cycles offer the opportunity for evaporation at multiple temperatures, and they do not require a liquid-vapor separator, the inefficiency of which can decrease the performance of the standard two-phase ejector cycle. Furthermore, it can be shown that the alternate ejector cycles offer potential advantages in terms of real applications without reducing the theoretical COP, compared to the standard two-phase ejector cycle, warranting further research on alternate two-phase ejector cycles. An alternate two-phase ejector cycle was constructed and used to evaluate ejector performance and cycle performance improvement when compared to expansion valve cycles. R134a and R1234yf were used as the working fluids in the experimental tests. These lowpressure working fluids offer less improvement potential with ejector cycles because of their lower throttling loss, compared to CO2. It was found that two-phase ejectors using these lowpressure working fluids were able to recover similar but lower fractions of the total expansion work available for recovery, compared to two-phase ejectors using CO2. The alternate ejector cycle was compared to an expansion valve cycle with two evaporation temperatures in order to match the cooling capacity in each evaporator. In this comparison, R134a showed COP improvements of up to 8 %, and R1234yf showed COP improvements of up to 12 %. The alternate ejector cycle was also compared to an expansion valve cycle with a single evaporation temperature, which may be a more practical means of comparison for many applications. In this case, R134a showed COP improvements of up to 5 %, and R1234yf showed COP improvements of up to 6 %. While not as high as the COP improvements that have been observed for CO2, the low-pressure working fluids R134a and R1234yf certainly offer some noticeable COP improvements on two-phase ejector cycles.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-12-12T16:43:45Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Lawrence_Neal.pdf: 2454424 bytes, checksum: 75f15adc2b558b6cc6d0dfdc3e560341 (MD5)","Made available in DSpace on 2013-02-03T19:35:43Z (GMT). No. of bitstreams: 2 Neal_Lawrence.pdf: 2454417 bytes, checksum: ef3941b4c892c40a4e66dffaa89b2f30 (MD5) license.txt: 4063 bytes, checksum: aae0d5f0ccac2bc7876af5e62aa22bf2 (MD5)"],"dc:identifier":["http://hdl.handle.net/2142/42337"],"dc:language":["en"],"dc:rights":["Copyright 2012 Neal D. Lawrence"],"dc:subject":["refrigeration","two-phase ejector"],"dc:title":["Analytical and experimental investigation of two-phase ejector cycles using low-pressure refrigerants"],"dc:type":["text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:33Z"}