{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/42139"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/42139","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Applying secondary ion mass spectrometry to cellular and model membranes to image component distribution and quantify composition","abstract":"Abstract Secondary ion mass spectrometry (SIMS) returns chemically specific data on membrane component distribution and composition. Of particular interest is a membrane protein’s lipid environment, which may play a role in the protein’s function. Herein, this thesis describes the synthesis of fluorine-functionalized colloidal gold immunolabels that facilitate the imaging of specific proteins in parallel with stable isotope labeled lipids in the cellular membrane using high-resolution SIMS performed with a NanoSIMS. Further, the spatial statistical analysis tools are outlined and applied to NanoSIMS data to test the hypothesis of colocalization of the flu virus protein hemagglutinin and sphingolipids. While the NanoSIMS has very high lateral resolution, it requires isotope labels for component identification. Time-of-flight SIMS (TOF-SIMS) detects large portions of the mass spectrum, allowing species to be identified by their fragmentation pattern. Ionization yields in TOF-SIMS, however, limit the lateral resolution and the maximum m/z that can be used consistently for analysis. These challenges can be addressed using multivariate analysis (MVA). TOF-SIMS and the MVA method partial least squares discriminant analysis (PLS-DA) was used to identify the differentiation stage of hematopoietic cells. Since TOF-SIMS is a location-specific technique, it can be used to investigate how varying chemical and material environments on one sample affect stem cell fate decisions. Another MVA method, partial least squares regression (PLSR), uses a calibrated model to return quantitative information from TOF-SIMS data. This was used to determine the concentration of cholesterol in homogeneous supported lipid membranes.","abstract_html":"Abstract Secondary ion mass spectrometry (SIMS) returns chemically specific data on membrane component distribution and composition. Of particular interest is a membrane protein’s lipid environment, which may play a role in the protein’s function. Herein, this thesis describes the synthesis of fluorine-functionalized colloidal gold immunolabels that facilitate the imaging of specific proteins in parallel with stable isotope labeled lipids in the cellular membrane using high-resolution SIMS performed with a NanoSIMS. Further, the spatial statistical analysis tools are outlined and applied to NanoSIMS data to test the hypothesis of colocalization of the flu virus protein hemagglutinin and sphingolipids. While the NanoSIMS has very high lateral resolution, it requires isotope labels for component identification. Time-of-flight SIMS (TOF-SIMS) detects large portions of the mass spectrum, allowing species to be identified by their fragmentation pattern. Ionization yields in TOF-SIMS, however, limit the lateral resolution and the maximum m/z that can be used consistently for analysis. These challenges can be addressed using multivariate analysis (MVA). TOF-SIMS and the MVA method partial least squares discriminant analysis (PLS-DA) was used to identify the differentiation stage of hematopoietic cells. Since TOF-SIMS is a location-specific technique, it can be used to investigate how varying chemical and material environments on one sample affect stem cell fate decisions. Another MVA method, partial least squares regression (PLSR), uses a calibrated model to return quantitative information from TOF-SIMS data. This was used to determine the concentration of cholesterol in homogeneous supported lipid membranes.","abstract_has_math":false,"creators":["Wilson, Robert"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":["Kraft, Mary L.","Bailey, Ryan C.","Murphy, Catherine J.","Suslick, Kenneth S."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-02-03T19:16:57Z","date_published":"2013-02-03T19:16:57Z","updated_at":"2026-07-22T22:25:31Z","subjects":["Time-of-flight Secondary ion mass spectrometry (TOF-SIMS)","Lipid bilayers","NanoSIMS","Nanoparticle","Surface analysis","Multivariate analysis","Partial least squares regression","Spatial statistics","Stem cells"],"languages":["en"],"rights":["Copyright 2012 Robert Wilson"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/42139","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kraft, Mary L.","Bailey, Ryan C.","Murphy, Catherine J.","Suslick, Kenneth S."]},{"key":"dc:creator","label":"Author","values":["Wilson, Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-02-03T19:16:57Z","2015-02-03T11:00:56Z","2012-12"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Time-of-flight Secondary ion mass spectrometry (TOF-SIMS)","Lipid bilayers","NanoSIMS","Nanoparticle","Surface analysis","Multivariate analysis","Partial least squares regression","Spatial statistics","Stem cells"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2012 Robert Wilson"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/42139"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Abstract Secondary ion mass spectrometry (SIMS) returns chemically specific data on membrane component distribution and composition. Of particular interest is a membrane protein’s lipid environment, which may play a role in the protein’s function. Herein, this thesis describes the synthesis of fluorine-functionalized colloidal gold immunolabels that facilitate the imaging of specific proteins in parallel with stable isotope labeled lipids in the cellular membrane using high-resolution SIMS performed with a NanoSIMS. Further, the spatial statistical analysis tools are outlined and applied to NanoSIMS data to test the hypothesis of colocalization of the flu virus protein hemagglutinin and sphingolipids. While the NanoSIMS has very high lateral resolution, it requires isotope labels for component identification. Time-of-flight SIMS (TOF-SIMS) detects large portions of the mass spectrum, allowing species to be identified by their fragmentation pattern. Ionization yields in TOF-SIMS, however, limit the lateral resolution and the maximum m/z that can be used consistently for analysis. These challenges can be addressed using multivariate analysis (MVA). TOF-SIMS and the MVA method partial least squares discriminant analysis (PLS-DA) was used to identify the differentiation stage of hematopoietic cells. Since TOF-SIMS is a location-specific technique, it can be used to investigate how varying chemical and material environments on one sample affect stem cell fate decisions. Another MVA method, partial least squares regression (PLSR), uses a calibrated model to return quantitative information from TOF-SIMS data. This was used to determine the concentration of cholesterol in homogeneous supported lipid membranes.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-08-02T14:17:04Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Wilson_Robert.pdf: 16981181 bytes, checksum: b6c66eacd2e54f3d6abdea1f487eeb3e (MD5)","Made available in DSpace on 2013-02-03T19:16:57Z (GMT). No. of bitstreams: 2 Robert_Wilson.pdf: 16981181 bytes, checksum: b6c66eacd2e54f3d6abdea1f487eeb3e (MD5) license.txt: 4063 bytes, checksum: 8c4caf815fef084f828623b8d3833532 (MD5)","Restriction data tranferred 2014-07-01T11:11:52-05:00 Original Data Group with Access UIUC Users [automated] Release Date: 2015-02-03 13:18:53 UTC Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Seth Robbins (srobbins@illinois.edu) on 2013-02-03T19:18:59Z Item is restricted until 2015-02-03T19:18:53Z","U of I Only Restriction Lifted for Item 42086 on 2015-02-03T11:00:56Z."]},{"key":"dc:title","label":"Title","values":["Applying secondary ion mass spectrometry to cellular and model membranes to image component distribution and quantify composition"]}]}],"canonical_facts":{"dc:contributor":["Kraft, Mary L.","Bailey, Ryan C.","Murphy, Catherine J.","Suslick, Kenneth S."],"dc:creator":["Wilson, Robert"],"dc:date":["2013-02-03T19:16:57Z","2015-02-03T11:00:56Z","2012-12"],"dc:description":["Abstract Secondary ion mass spectrometry (SIMS) returns chemically specific data on membrane component distribution and composition. Of particular interest is a membrane protein’s lipid environment, which may play a role in the protein’s function. Herein, this thesis describes the synthesis of fluorine-functionalized colloidal gold immunolabels that facilitate the imaging of specific proteins in parallel with stable isotope labeled lipids in the cellular membrane using high-resolution SIMS performed with a NanoSIMS. Further, the spatial statistical analysis tools are outlined and applied to NanoSIMS data to test the hypothesis of colocalization of the flu virus protein hemagglutinin and sphingolipids. While the NanoSIMS has very high lateral resolution, it requires isotope labels for component identification. Time-of-flight SIMS (TOF-SIMS) detects large portions of the mass spectrum, allowing species to be identified by their fragmentation pattern. Ionization yields in TOF-SIMS, however, limit the lateral resolution and the maximum m/z that can be used consistently for analysis. These challenges can be addressed using multivariate analysis (MVA). TOF-SIMS and the MVA method partial least squares discriminant analysis (PLS-DA) was used to identify the differentiation stage of hematopoietic cells. Since TOF-SIMS is a location-specific technique, it can be used to investigate how varying chemical and material environments on one sample affect stem cell fate decisions. Another MVA method, partial least squares regression (PLSR), uses a calibrated model to return quantitative information from TOF-SIMS data. This was used to determine the concentration of cholesterol in homogeneous supported lipid membranes.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-08-02T14:17:04Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 Wilson_Robert.pdf: 16981181 bytes, checksum: b6c66eacd2e54f3d6abdea1f487eeb3e (MD5)","Made available in DSpace on 2013-02-03T19:16:57Z (GMT). No. of bitstreams: 2 Robert_Wilson.pdf: 16981181 bytes, checksum: b6c66eacd2e54f3d6abdea1f487eeb3e (MD5) license.txt: 4063 bytes, checksum: 8c4caf815fef084f828623b8d3833532 (MD5)","Restriction data tranferred 2014-07-01T11:11:52-05:00 Original Data Group with Access UIUC Users [automated] Release Date: 2015-02-03 13:18:53 UTC Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Seth Robbins (srobbins@illinois.edu) on 2013-02-03T19:18:59Z Item is restricted until 2015-02-03T19:18:53Z","U of I Only Restriction Lifted for Item 42086 on 2015-02-03T11:00:56Z."],"dc:identifier":["http://hdl.handle.net/2142/42139"],"dc:language":["en"],"dc:rights":["Copyright 2012 Robert Wilson"],"dc:subject":["Time-of-flight Secondary ion mass spectrometry (TOF-SIMS)","Lipid bilayers","NanoSIMS","Nanoparticle","Surface analysis","Multivariate analysis","Partial least squares regression","Spatial statistics","Stem cells"],"dc:title":["Applying secondary ion mass spectrometry to cellular and model membranes to image component distribution and quantify composition"],"dc:type":["text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:31Z"}