{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/31108"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/31108","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Strategies for developing ultrathin, high-density, actively multiplexed neural mapping device","abstract":"Electronic systems that integrate with biological systems must be able to accommodate the dynamic mechanical characteristics of the tissue. With the rise in the interest of diagnosing and treating brain diseases it is critical that electrodes involving brain/machine interfaces have minimal effect on the brain while ensuring conformal coverage and good signal quality. A two-stage attempt is described in this thesis, where technological advancement involved in the producing of an extremely conformal platform is described, followed by the introduction of a high-density, actively multiplexed, flexible, and foldable sensor array. Experimental data show that as substrate thickness decreased the signal quality increased. Thin mesh-type systems showed further improvements in electrode response. An array of ultrathin, highly dense silicon nanomembrane transistors was fabricated on flexible plastic substrates and recorded neural activity with high spatial resolution. Brain activities, such as sleep spindles, single-trial visual evoked responses, and electrographic seizures could be successfully recorded. Analysis of the recorded data reveals the propagation of the punctual spatial patterns composed of planar and spiral waves during epileptic stage.","abstract_html":"Electronic systems that integrate with biological systems must be able to accommodate the dynamic mechanical characteristics of the tissue. With the rise in the interest of diagnosing and treating brain diseases it is critical that electrodes involving brain/machine interfaces have minimal effect on the brain while ensuring conformal coverage and good signal quality. A two-stage attempt is described in this thesis, where technological advancement involved in the producing of an extremely conformal platform is described, followed by the introduction of a high-density, actively multiplexed, flexible, and foldable sensor array. Experimental data show that as substrate thickness decreased the signal quality increased. Thin mesh-type systems showed further improvements in electrode response. An array of ultrathin, highly dense silicon nanomembrane transistors was fabricated on flexible plastic substrates and recorded neural activity with high spatial resolution. Brain activities, such as sleep spindles, single-trial visual evoked responses, and electrographic seizures could be successfully recorded. Analysis of the recorded data reveals the propagation of the punctual spatial patterns composed of planar and spiral waves during epileptic stage.","abstract_has_math":false,"creators":["Kim, Yun Soung"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Materials Science & Engr","degree_department":null,"school":null,"contributors":["Rogers, John A."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-05-22T00:28:36Z","date_published":"2012-05-22T00:28:36Z","updated_at":"2026-07-22T22:25:30Z","subjects":["flexible","neural","ultrathin","multiplexed","silk"],"languages":["en"],"rights":["Copyright 2012 Yun Soung Kim"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/31108","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rogers, John A."]},{"key":"dc:creator","label":"Author","values":["Kim, Yun Soung"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2012-05-22T00:28:36Z","2012-05"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Materials Science & Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["flexible","neural","ultrathin","multiplexed","silk"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2012 Yun Soung Kim"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/31108"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Electronic systems that integrate with biological systems must be able to accommodate the dynamic mechanical characteristics of the tissue. With the rise in the interest of diagnosing and treating brain diseases it is critical that electrodes involving brain/machine interfaces have minimal effect on the brain while ensuring conformal coverage and good signal quality. A two-stage attempt is described in this thesis, where technological advancement involved in the producing of an extremely conformal platform is described, followed by the introduction of a high-density, actively multiplexed, flexible, and foldable sensor array. Experimental data show that as substrate thickness decreased the signal quality increased. Thin mesh-type systems showed further improvements in electrode response. An array of ultrathin, highly dense silicon nanomembrane transistors was fabricated on flexible plastic substrates and recorded neural activity with high spatial resolution. Brain activities, such as sleep spindles, single-trial visual evoked responses, and electrographic seizures could be successfully recorded. Analysis of the recorded data reveals the propagation of the punctual spatial patterns composed of planar and spiral waves during epileptic stage.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-04-25T19:50:19Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 kim_yun soung.pdf: 2726101 bytes, checksum: 89043150e7bfd0cb5fc3c176fd8a906e (MD5)","Made available in DSpace on 2012-05-22T00:28:36Z (GMT). No. of bitstreams: 2 Kim_YunSoung.pdf: 2726314 bytes, checksum: 3ad86e72163064293780ad2ef4572c9a (MD5) license.txt: 4055 bytes, checksum: ad9439c07287db30b467c6ee928d8c5a (MD5)"]},{"key":"dc:title","label":"Title","values":["Strategies for developing ultrathin, high-density, actively multiplexed neural mapping device"]}]}],"canonical_facts":{"dc:contributor":["Rogers, John A."],"dc:creator":["Kim, Yun Soung"],"dc:date":["2012-05-22T00:28:36Z","2012-05"],"dc:description":["Electronic systems that integrate with biological systems must be able to accommodate the dynamic mechanical characteristics of the tissue. With the rise in the interest of diagnosing and treating brain diseases it is critical that electrodes involving brain/machine interfaces have minimal effect on the brain while ensuring conformal coverage and good signal quality. A two-stage attempt is described in this thesis, where technological advancement involved in the producing of an extremely conformal platform is described, followed by the introduction of a high-density, actively multiplexed, flexible, and foldable sensor array. Experimental data show that as substrate thickness decreased the signal quality increased. Thin mesh-type systems showed further improvements in electrode response. An array of ultrathin, highly dense silicon nanomembrane transistors was fabricated on flexible plastic substrates and recorded neural activity with high spatial resolution. Brain activities, such as sleep spindles, single-trial visual evoked responses, and electrographic seizures could be successfully recorded. Analysis of the recorded data reveals the propagation of the punctual spatial patterns composed of planar and spiral waves during epileptic stage.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2012-04-25T19:50:19Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 1 kim_yun soung.pdf: 2726101 bytes, checksum: 89043150e7bfd0cb5fc3c176fd8a906e (MD5)","Made available in DSpace on 2012-05-22T00:28:36Z (GMT). No. of bitstreams: 2 Kim_YunSoung.pdf: 2726314 bytes, checksum: 3ad86e72163064293780ad2ef4572c9a (MD5) license.txt: 4055 bytes, checksum: ad9439c07287db30b467c6ee928d8c5a (MD5)"],"dc:identifier":["http://hdl.handle.net/2142/31108"],"dc:language":["en"],"dc:rights":["Copyright 2012 Yun Soung Kim"],"dc:subject":["flexible","neural","ultrathin","multiplexed","silk"],"dc:title":["Strategies for developing ultrathin, high-density, actively multiplexed neural mapping device"],"dc:type":["text"],"thesis:degree_discipline":["Materials Science & Engr"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:30Z"}