{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/22622"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/22622","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Heat source transfer functions and their application to low temperature radiant heating systems","abstract":"Radiant heating systems have been identified by segments of the HVAC industry as technology which can potentially reduce the energy consumption of buildings. As a result of higher mean radiant temperatures within radiantly heating structures, it has been hypothesized that these systems can provide an equally comfortable thermal environment at lower thermostatic temperatures than conventional forced air systems. Previously, there has been no fundamentally sound way to evaluate this hypothesis. Thus, the main goal of this research was to develop the fundamental technology that correctly accounts for the transient heat conduction inherent in the low temperature systems, fully models the complex interactions with the rest of the building, and evaluates the resulting thermal environment created by the system.","abstract_html":"Radiant heating systems have been identified by segments of the HVAC industry as technology which can potentially reduce the energy consumption of buildings. As a result of higher mean radiant temperatures within radiantly heating structures, it has been hypothesized that these systems can provide an equally comfortable thermal environment at lower thermostatic temperatures than conventional forced air systems. Previously, there has been no fundamentally sound way to evaluate this hypothesis. Thus, the main goal of this research was to develop the fundamental technology that correctly accounts for the transient heat conduction inherent in the low temperature systems, fully models the complex interactions with the rest of the building, and evaluates the resulting thermal environment created by the system.","abstract_has_math":false,"creators":["Strand, Richard Karl"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Mechanical Science and Engineering","degree_department":null,"school":null,"contributors":["Pedersen, Curtis O."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-05-07T13:45:50Z","date_published":"2011-05-07T13:45:50Z","updated_at":"2026-07-22T22:25:20Z","subjects":["Engineering, Mechanical"],"languages":["eng"],"rights":["Copyright 1995 Strand, Richard Karl"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["AAI9543736","(UMI)AAI9543736"],"render_values":[{"text":"AAI9543736","href":null,"code":true},{"text":"(UMI)AAI9543736","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/22622","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Pedersen, Curtis O."]},{"key":"dc:creator","label":"Author","values":["Strand, Richard Karl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-05-07T13:45:50Z","10000-01-01","1995"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Science and Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 1995 Strand, Richard Karl"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["AAI9543736","(UMI)AAI9543736","http://hdl.handle.net/2142/22622"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Radiant heating systems have been identified by segments of the HVAC industry as technology which can potentially reduce the energy consumption of buildings. As a result of higher mean radiant temperatures within radiantly heating structures, it has been hypothesized that these systems can provide an equally comfortable thermal environment at lower thermostatic temperatures than conventional forced air systems. Previously, there has been no fundamentally sound way to evaluate this hypothesis. Thus, the main goal of this research was to develop the fundamental technology that correctly accounts for the transient heat conduction inherent in the low temperature systems, fully models the complex interactions with the rest of the building, and evaluates the resulting thermal environment created by the system.","Time series analysis has been established by previous studies as an accurate and efficient method of calculating transient one dimensional heat conduction through standard building elements. The heat source transfer functions (QTFs) derived in this work are an extension of time series analysis to include the effects of an embedded source or sink of a radiant heating or cooling system on transient conduction. Heat source transfer functions were obtained through both the more traditional Laplace transform method and the newer state space method which could be adapted to two dimensional solutions. Through comparison to an analytical solution and experimental data, the concept of heat source transfer functions was validated.","The incorporation of a low temperature radiant system model into the Integrated Building Loads Analysis and System Thermodynamics (IBLAST) program combines the advantages of QTFs with a proven energy balance based simulation that thoroughly describes building heat transfer processes. The new model provides researcher and designer with an engineering tool that can compare radiant and forced air systems on the basis of equivalent thermal environments as defined by accepted thermal comfort models.","Made available in DSpace on 2011-05-07T13:45:50Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9543736.pdf: 6636790 bytes, checksum: 416afc218d0a3625e79c5763cac25ec5 (MD5) Previous issue date: 1995","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:58:53Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:27:43-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"]},{"key":"dc:title","label":"Title","values":["Heat source transfer functions and their application to low temperature radiant heating systems"]}]}],"canonical_facts":{"dc:contributor":["Pedersen, Curtis O."],"dc:creator":["Strand, Richard Karl"],"dc:date":["2011-05-07T13:45:50Z","10000-01-01","1995"],"dc:description":["Radiant heating systems have been identified by segments of the HVAC industry as technology which can potentially reduce the energy consumption of buildings. As a result of higher mean radiant temperatures within radiantly heating structures, it has been hypothesized that these systems can provide an equally comfortable thermal environment at lower thermostatic temperatures than conventional forced air systems. Previously, there has been no fundamentally sound way to evaluate this hypothesis. Thus, the main goal of this research was to develop the fundamental technology that correctly accounts for the transient heat conduction inherent in the low temperature systems, fully models the complex interactions with the rest of the building, and evaluates the resulting thermal environment created by the system.","Time series analysis has been established by previous studies as an accurate and efficient method of calculating transient one dimensional heat conduction through standard building elements. The heat source transfer functions (QTFs) derived in this work are an extension of time series analysis to include the effects of an embedded source or sink of a radiant heating or cooling system on transient conduction. Heat source transfer functions were obtained through both the more traditional Laplace transform method and the newer state space method which could be adapted to two dimensional solutions. Through comparison to an analytical solution and experimental data, the concept of heat source transfer functions was validated.","The incorporation of a low temperature radiant system model into the Integrated Building Loads Analysis and System Thermodynamics (IBLAST) program combines the advantages of QTFs with a proven energy balance based simulation that thoroughly describes building heat transfer processes. The new model provides researcher and designer with an engineering tool that can compare radiant and forced air systems on the basis of equivalent thermal environments as defined by accepted thermal comfort models.","Made available in DSpace on 2011-05-07T13:45:50Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9543736.pdf: 6636790 bytes, checksum: 416afc218d0a3625e79c5763cac25ec5 (MD5) Previous issue date: 1995","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:58:53Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:27:43-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"],"dc:identifier":["AAI9543736","(UMI)AAI9543736","http://hdl.handle.net/2142/22622"],"dc:language":["eng"],"dc:rights":["Copyright 1995 Strand, Richard Karl"],"dc:subject":["Engineering, Mechanical"],"dc:title":["Heat source transfer functions and their application to low temperature radiant heating systems"],"dc:type":["text"],"thesis:degree_discipline":["Mechanical Science and Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:20Z"}