{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/22603"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/22603","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Measurement of volumetric blood flow using ultrasound time-domain correlation","abstract":"The Ultrasound Time Domain Correlation (UTDC) technique can accurately and precisely estimate the volumetric fluid flow through a circular vessel without prior knowledge of the vessel diameter, flow velocity profile, or transducer measurement angle. This technique observes the change in arrival time (instead of frequency, as with Doppler techniques) of ultrasound reflected from scatterers. If a vessel with moving fluid is insonated by two ultrasonic pulses separated by time T, the scatterers within the ultrasonic beam will move some distance D between the first and second pulse. There will be a difference $\\tau$ in the arrival times of the two pulses since the scatterer has moved. The scatterer velocity can be calculated from the time difference $\\tau$. By sampling the velocity at different positions along the vessel, the transducer measurement angle and the volumetric flow can be calculated.","abstract_html":"The Ultrasound Time Domain Correlation (UTDC) technique can accurately and precisely estimate the volumetric fluid flow through a circular vessel without prior knowledge of the vessel diameter, flow velocity profile, or transducer measurement angle. This technique observes the change in arrival time (instead of frequency, as with Doppler techniques) of ultrasound reflected from scatterers. If a vessel with moving fluid is insonated by two ultrasonic pulses separated by time T, the scatterers within the ultrasonic beam will move some distance D between the first and second pulse. There will be a difference $\\tau$ in the arrival times of the two pulses since the scatterer has moved. The scatterer velocity can be calculated from the time difference $\\tau$. By sampling the velocity at different positions along the vessel, the transducer measurement angle and the volumetric flow can be calculated.","abstract_has_math":true,"creators":["Hein, Ilmar Arthur"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["O'Brien, William D."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-05-07T13:45:11Z","date_published":"2011-05-07T13:45:11Z","updated_at":"2026-07-22T22:25:20Z","subjects":["Engineering, Biomedical","Engineering, Electronics and Electrical","Biophysics, Medical"],"languages":["eng"],"rights":["Copyright 1991 Hein, Ilmar Arthur"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["AAI9124423","(UMI)AAI9124423"],"render_values":[{"text":"AAI9124423","href":null,"code":true},{"text":"(UMI)AAI9124423","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/22603","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["O'Brien, William D."]},{"key":"dc:creator","label":"Author","values":["Hein, Ilmar Arthur"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-05-07T13:45:11Z","10000-01-01","1991"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Biomedical","Engineering, Electronics and Electrical","Biophysics, Medical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 1991 Hein, Ilmar Arthur"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["AAI9124423","(UMI)AAI9124423","http://hdl.handle.net/2142/22603"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The Ultrasound Time Domain Correlation (UTDC) technique can accurately and precisely estimate the volumetric fluid flow through a circular vessel without prior knowledge of the vessel diameter, flow velocity profile, or transducer measurement angle. This technique observes the change in arrival time (instead of frequency, as with Doppler techniques) of ultrasound reflected from scatterers. If a vessel with moving fluid is insonated by two ultrasonic pulses separated by time T, the scatterers within the ultrasonic beam will move some distance D between the first and second pulse. There will be a difference $\\tau$ in the arrival times of the two pulses since the scatterer has moved. The scatterer velocity can be calculated from the time difference $\\tau$. By sampling the velocity at different positions along the vessel, the transducer measurement angle and the volumetric flow can be calculated.","Previous research has shown that this technique can estimate the volumetric flow rate of constant, fully developed laminar flow in a blood flow phantom with an accuracy of 15%. This dissertation represents continuing development of the UTDC technique towards the eventual goal of producing a clinical quantitative blood flowmeter. Blood flow phantom measurements have been made in conditions more closely resembling in vivo conditions, such as pulsatile flow, multiple vessels, different size vessels, and attenuation. A real-time UTDC blood flowmeter system interfaced to a commercial ultrasound imager has been constructed and in vivo measurements have been made in canines and humans.","Made available in DSpace on 2011-05-07T13:45:11Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9124423.pdf: 8933545 bytes, checksum: f4f3a6e1d9755c758c5bc91e40feb8f5 (MD5) Previous issue date: 1991","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:58:44Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:27:39-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"]},{"key":"dc:title","label":"Title","values":["Measurement of volumetric blood flow using ultrasound time-domain correlation"]}]}],"canonical_facts":{"dc:contributor":["O'Brien, William D."],"dc:creator":["Hein, Ilmar Arthur"],"dc:date":["2011-05-07T13:45:11Z","10000-01-01","1991"],"dc:description":["The Ultrasound Time Domain Correlation (UTDC) technique can accurately and precisely estimate the volumetric fluid flow through a circular vessel without prior knowledge of the vessel diameter, flow velocity profile, or transducer measurement angle. This technique observes the change in arrival time (instead of frequency, as with Doppler techniques) of ultrasound reflected from scatterers. If a vessel with moving fluid is insonated by two ultrasonic pulses separated by time T, the scatterers within the ultrasonic beam will move some distance D between the first and second pulse. There will be a difference $\\tau$ in the arrival times of the two pulses since the scatterer has moved. The scatterer velocity can be calculated from the time difference $\\tau$. By sampling the velocity at different positions along the vessel, the transducer measurement angle and the volumetric flow can be calculated.","Previous research has shown that this technique can estimate the volumetric flow rate of constant, fully developed laminar flow in a blood flow phantom with an accuracy of 15%. This dissertation represents continuing development of the UTDC technique towards the eventual goal of producing a clinical quantitative blood flowmeter. Blood flow phantom measurements have been made in conditions more closely resembling in vivo conditions, such as pulsatile flow, multiple vessels, different size vessels, and attenuation. A real-time UTDC blood flowmeter system interfaced to a commercial ultrasound imager has been constructed and in vivo measurements have been made in canines and humans.","Made available in DSpace on 2011-05-07T13:45:11Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9124423.pdf: 8933545 bytes, checksum: f4f3a6e1d9755c758c5bc91e40feb8f5 (MD5) Previous issue date: 1991","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:58:44Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:27:39-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"],"dc:identifier":["AAI9124423","(UMI)AAI9124423","http://hdl.handle.net/2142/22603"],"dc:language":["eng"],"dc:rights":["Copyright 1991 Hein, Ilmar Arthur"],"dc:subject":["Engineering, Biomedical","Engineering, Electronics and Electrical","Biophysics, Medical"],"dc:title":["Measurement of volumetric blood flow using ultrasound time-domain correlation"],"dc:type":["text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:20Z"}