{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/22465"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/22465","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Thermal regeneration of activated carbon for the treatment of drinking water","abstract":"Granular activated carbon (GAC) has been specified as the best available technology (BAT) for the removal of synthetic organic compounds from drinking water. Drinking water utilities which use GAC must either replace or regenerate the carbon periodically. Thermal regeneration is one option for handling spent carbon.","abstract_html":"Granular activated carbon (GAC) has been specified as the best available technology (BAT) for the removal of synthetic organic compounds from drinking water. Drinking water utilities which use GAC must either replace or regenerate the carbon periodically. Thermal regeneration is one option for handling spent carbon.","abstract_has_math":false,"creators":["Waer, Mark Alan"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Snoeyink, Vernon L."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-05-07T13:40:43Z","date_published":"2011-05-07T13:40:43Z","updated_at":"2026-07-22T22:25:20Z","subjects":["Engineering, Civil","Engineering, Sanitary and Municipal"],"languages":["eng"],"rights":["Copyright 1996 Waer, Mark Alan"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["9780591088977","AAI9702704","(UMI)AAI9702704"],"render_values":[{"text":"9780591088977","href":null,"code":true},{"text":"AAI9702704","href":null,"code":true},{"text":"(UMI)AAI9702704","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/22465","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Snoeyink, Vernon L."]},{"key":"dc:creator","label":"Author","values":["Waer, Mark Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-05-07T13:40:43Z","10000-01-01","1996"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Civil","Engineering, Sanitary and Municipal"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 1996 Waer, Mark Alan"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["9780591088977","AAI9702704","(UMI)AAI9702704","http://hdl.handle.net/2142/22465"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Granular activated carbon (GAC) has been specified as the best available technology (BAT) for the removal of synthetic organic compounds from drinking water. Drinking water utilities which use GAC must either replace or regenerate the carbon periodically. Thermal regeneration is one option for handling spent carbon.","The effect of several parameters on volume losses and on the recovery of adsorption capacity of granular activated carbon (GAC) during thermal regeneration has been studied. Parameters investigated during this study include the temperature of the regeneration step, the time of regeneration, the type of oxidant, and the oxidant flow rate.","The apparent (bulk) density was found to be a good parameter for monitoring thermal regeneration. Other carbon properties followed during regeneration include the surface area (determined by nitrogen isotherm), the micropore volume and the mesopore volume. Optimum regeneration conditions were found to be dependant on the type of GAC being regenerated. The effect of multiple regenerations on carbon properties is discussed.","Made available in DSpace on 2011-05-07T13:40:43Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9702704.pdf: 3921607 bytes, checksum: 78b3ffe0b58d42002bf4f3ef9892c287 (MD5) Previous issue date: 1996","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:57:48Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:27:08-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"]},{"key":"dc:title","label":"Title","values":["Thermal regeneration of activated carbon for the treatment of drinking water"]}]}],"canonical_facts":{"dc:contributor":["Snoeyink, Vernon L."],"dc:creator":["Waer, Mark Alan"],"dc:date":["2011-05-07T13:40:43Z","10000-01-01","1996"],"dc:description":["Granular activated carbon (GAC) has been specified as the best available technology (BAT) for the removal of synthetic organic compounds from drinking water. Drinking water utilities which use GAC must either replace or regenerate the carbon periodically. Thermal regeneration is one option for handling spent carbon.","The effect of several parameters on volume losses and on the recovery of adsorption capacity of granular activated carbon (GAC) during thermal regeneration has been studied. Parameters investigated during this study include the temperature of the regeneration step, the time of regeneration, the type of oxidant, and the oxidant flow rate.","The apparent (bulk) density was found to be a good parameter for monitoring thermal regeneration. Other carbon properties followed during regeneration include the surface area (determined by nitrogen isotherm), the micropore volume and the mesopore volume. Optimum regeneration conditions were found to be dependant on the type of GAC being regenerated. The effect of multiple regenerations on carbon properties is discussed.","Made available in DSpace on 2011-05-07T13:40:43Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9702704.pdf: 3921607 bytes, checksum: 78b3ffe0b58d42002bf4f3ef9892c287 (MD5) Previous issue date: 1996","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:57:48Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:27:08-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"],"dc:identifier":["9780591088977","AAI9702704","(UMI)AAI9702704","http://hdl.handle.net/2142/22465"],"dc:language":["eng"],"dc:rights":["Copyright 1996 Waer, Mark Alan"],"dc:subject":["Engineering, Civil","Engineering, Sanitary and Municipal"],"dc:title":["Thermal regeneration of activated carbon for the treatment of drinking water"],"dc:type":["text"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:20Z"}