{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/22133"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/22133","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"A fundamental study of two-dimensional room ventilation flows under isothermal and non-isothermal conditions","abstract":"Understanding room air distribution is essential to the design of a ventilation system and the control of room thermal and air quality conditions. To investigate the various aspects of room air distribution, a Room Ventilation Simulator was developed with several unique features: an outer room with a HVAC (Heating Ventilating and Air-Conditioning) system to simulate different weather conditions by controlling the ambient air environment around the test room; an inner test room of modular design to facilitate changing room dimensions and configurations; an independent HVAC system for the inner test room to study different air supplies; an air delivery system capable of providing air flow rate of 2 to 52 air changes per hour; a uniform floor heating system of 48 individually controllable panels to simulate internal heat loads; a computer controlled data acquisition and probe positioning system to allow automatic measurements at precisely positioned locations; and a flow visualization system to record room air flow patterns. Additionally, computer software was developed for data analyses.","abstract_html":"Understanding room air distribution is essential to the design of a ventilation system and the control of room thermal and air quality conditions. To investigate the various aspects of room air distribution, a Room Ventilation Simulator was developed with several unique features: an outer room with a HVAC (Heating Ventilating and Air-Conditioning) system to simulate different weather conditions by controlling the ambient air environment around the test room; an inner test room of modular design to facilitate changing room dimensions and configurations; an independent HVAC system for the inner test room to study different air supplies; an air delivery system capable of providing air flow rate of 2 to 52 air changes per hour; a uniform floor heating system of 48 individually controllable panels to simulate internal heat loads; a computer controlled data acquisition and probe positioning system to allow automatic measurements at precisely positioned locations; and a flow visualization system to record room air flow patterns. Additionally, computer software was developed for data analyses.","abstract_has_math":false,"creators":["Zhang, Jianshun S."],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Agricultural Engineering","degree_department":null,"school":null,"contributors":["Christianson, Leslie L."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-05-07T13:30:02Z","date_published":"2011-05-07T13:30:02Z","updated_at":"2026-07-22T22:25:19Z","subjects":["Engineering, Agricultural","Engineering, Mechanical"],"languages":["eng"],"rights":["Copyright 1991 Zhang, Jianshun S."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["AAI9211055","(UMI)AAI9211055"],"render_values":[{"text":"AAI9211055","href":null,"code":true},{"text":"(UMI)AAI9211055","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/22133","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Christianson, Leslie L."]},{"key":"dc:creator","label":"Author","values":["Zhang, Jianshun S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-05-07T13:30:02Z","10000-01-01","1991"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Agricultural Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Agricultural","Engineering, Mechanical"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 1991 Zhang, Jianshun S."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["AAI9211055","(UMI)AAI9211055","http://hdl.handle.net/2142/22133"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Understanding room air distribution is essential to the design of a ventilation system and the control of room thermal and air quality conditions. To investigate the various aspects of room air distribution, a Room Ventilation Simulator was developed with several unique features: an outer room with a HVAC (Heating Ventilating and Air-Conditioning) system to simulate different weather conditions by controlling the ambient air environment around the test room; an inner test room of modular design to facilitate changing room dimensions and configurations; an independent HVAC system for the inner test room to study different air supplies; an air delivery system capable of providing air flow rate of 2 to 52 air changes per hour; a uniform floor heating system of 48 individually controllable panels to simulate internal heat loads; a computer controlled data acquisition and probe positioning system to allow automatic measurements at precisely positioned locations; and a flow visualization system to record room air flow patterns. Additionally, computer software was developed for data analyses.","Detailed spatial distributions of velocities, turbulence intensities, turbulent kinetic energy and temperatures were measured within a full and 1/4th scale test rooms and at the air diffusers. Such detailed data are useful for understanding the room air flow characteristics and for evaluating and improving numerical simulation models of room air motion. Particularly, the effects of diffuser air velocity and internal heat load on the mean and turbulent characteristics of the room air flows were analyzed using the full scale data.","Scaling methods for predicting room air motion were investigated theoretically and experimentally. For non-isothermal room air flows, the critical Archimedes number, at which the diffuser air jet fell immediately after entering the room, decreased when the room dimensions decreased. A new scaling method was proposed based on the relative deviation of Archimedes number from its critical value. Comparison between the full and 1/4th scale tests indicated that the new method has improvements over previous ones.","Additionally, the uncertainty of a hot wire anemometer and its capability of resolving velocity components in low velocity measurements ($<$50 ft/min or 0.25 m/s) were quantified.","Made available in DSpace on 2011-05-07T13:30:02Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9211055.pdf: 8417426 bytes, checksum: 00a6ded5a17e081ef420ebbbba644787 (MD5) Previous issue date: 1991","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:55:33Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:25:54-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"]},{"key":"dc:title","label":"Title","values":["A fundamental study of two-dimensional room ventilation flows under isothermal and non-isothermal conditions"]}]}],"canonical_facts":{"dc:contributor":["Christianson, Leslie L."],"dc:creator":["Zhang, Jianshun S."],"dc:date":["2011-05-07T13:30:02Z","10000-01-01","1991"],"dc:description":["Understanding room air distribution is essential to the design of a ventilation system and the control of room thermal and air quality conditions. To investigate the various aspects of room air distribution, a Room Ventilation Simulator was developed with several unique features: an outer room with a HVAC (Heating Ventilating and Air-Conditioning) system to simulate different weather conditions by controlling the ambient air environment around the test room; an inner test room of modular design to facilitate changing room dimensions and configurations; an independent HVAC system for the inner test room to study different air supplies; an air delivery system capable of providing air flow rate of 2 to 52 air changes per hour; a uniform floor heating system of 48 individually controllable panels to simulate internal heat loads; a computer controlled data acquisition and probe positioning system to allow automatic measurements at precisely positioned locations; and a flow visualization system to record room air flow patterns. Additionally, computer software was developed for data analyses.","Detailed spatial distributions of velocities, turbulence intensities, turbulent kinetic energy and temperatures were measured within a full and 1/4th scale test rooms and at the air diffusers. Such detailed data are useful for understanding the room air flow characteristics and for evaluating and improving numerical simulation models of room air motion. Particularly, the effects of diffuser air velocity and internal heat load on the mean and turbulent characteristics of the room air flows were analyzed using the full scale data.","Scaling methods for predicting room air motion were investigated theoretically and experimentally. For non-isothermal room air flows, the critical Archimedes number, at which the diffuser air jet fell immediately after entering the room, decreased when the room dimensions decreased. A new scaling method was proposed based on the relative deviation of Archimedes number from its critical value. Comparison between the full and 1/4th scale tests indicated that the new method has improvements over previous ones.","Additionally, the uncertainty of a hot wire anemometer and its capability of resolving velocity components in low velocity measurements ($<$50 ft/min or 0.25 m/s) were quantified.","Made available in DSpace on 2011-05-07T13:30:02Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9211055.pdf: 8417426 bytes, checksum: 00a6ded5a17e081ef420ebbbba644787 (MD5) Previous issue date: 1991","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:55:33Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:25:54-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"],"dc:identifier":["AAI9211055","(UMI)AAI9211055","http://hdl.handle.net/2142/22133"],"dc:language":["eng"],"dc:rights":["Copyright 1991 Zhang, Jianshun S."],"dc:subject":["Engineering, Agricultural","Engineering, Mechanical"],"dc:title":["A fundamental study of two-dimensional room ventilation flows under isothermal and non-isothermal conditions"],"dc:type":["text"],"thesis:degree_discipline":["Agricultural Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:19Z"}