{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/20521"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/20521","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Response of an unreinforced masonry building during the Loma Prieta earthquake","abstract":"The subject structure of this study is a two-story historic building and former firehouse located in downtown Gilroy, California. The structure was built in 1890 and it is one of the first URM buildings that has been both instrumented and subjected to a moderate earthquake in U.S. history. Recorded peak ground accelerations were as high as 0.29g and peak roof accelerations as high as 0.79g. Considerable amplifications of the peak accelerations between the ground and the roof were observed. The former firehouse withstood the Loma Prieta Earthquake with little damage.","abstract_html":"The subject structure of this study is a two-story historic building and former firehouse located in downtown Gilroy, California. The structure was built in 1890 and it is one of the first URM buildings that has been both instrumented and subjected to a moderate earthquake in U.S. history. Recorded peak ground accelerations were as high as 0.29g and peak roof accelerations as high as 0.79g. Considerable amplifications of the peak accelerations between the ground and the roof were observed. The former firehouse withstood the Loma Prieta Earthquake with little damage.","abstract_has_math":false,"creators":["Tena-Colunga, Arturo"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Abrams, Daniel P."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-05-07T12:41:37Z","date_published":"2011-05-07T12:41:37Z","updated_at":"2026-07-22T22:25:16Z","subjects":["Engineering, Civil"],"languages":["eng"],"rights":["Copyright 1992 Tena-Colunga, Arturo"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["(UMI)AAI9236605","AAI9236605"],"render_values":[{"text":"(UMI)AAI9236605","href":null,"code":true},{"text":"AAI9236605","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/2142/20521","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Abrams, Daniel P."]},{"key":"dc:creator","label":"Author","values":["Tena-Colunga, Arturo"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-05-07T12:41:37Z","10000-01-01","1992"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering, Civil"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 1992 Tena-Colunga, Arturo"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["(UMI)AAI9236605","http://hdl.handle.net/2142/20521","AAI9236605"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The subject structure of this study is a two-story historic building and former firehouse located in downtown Gilroy, California. The structure was built in 1890 and it is one of the first URM buildings that has been both instrumented and subjected to a moderate earthquake in U.S. history. Recorded peak ground accelerations were as high as 0.29g and peak roof accelerations as high as 0.79g. Considerable amplifications of the peak accelerations between the ground and the roof were observed. The former firehouse withstood the Loma Prieta Earthquake with little damage.","Unreinforced masonry construction used in Northern California at the turn of this century was similar throughout the United States. Because moderate earthquakes are expected east of the Rocky Mountains, the response of the firehouse can help foretell the earthquake hazard in the eastern and midwestern United States. The ground motions recorded at the firehouse represent an upper bound for assessing possible hazards associated with similarly constructed buildings in the eastern United States. Since the firehouse was not appreciably damaged, even with these high accelerations, there is hope that similar historic buildings across the nation may survive a future earthquake. However, such extrapolation is not warranted unless a detailed investigation is done to examine the reasons for the superior performance.","The objectives of this study are the following: (1) Investigate the reasons of the survival of the firehouse of Gilroy with the use of both simplified and state-of-the-art methods. (2) Present a simplified discrete MDOF dynamic model developed for the seismic evaluation of the firehouse and similar URM buildings with flexible diaphragms. (3) Correlate the recorded, observed and computed response of the firehouse with estimates of dynamic response and prescribed allowable stress limits by state-of-the-art masonry and seismic codes.","Made available in DSpace on 2011-05-07T12:41:37Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9236605.pdf: 16775450 bytes, checksum: 0955946d1e2dc0e91ca2137fbf2f9898 (MD5) Previous issue date: 1992","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:44:27Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:19:34-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"]},{"key":"dc:title","label":"Title","values":["Response of an unreinforced masonry building during the Loma Prieta earthquake"]}]}],"canonical_facts":{"dc:contributor":["Abrams, Daniel P."],"dc:creator":["Tena-Colunga, Arturo"],"dc:date":["2011-05-07T12:41:37Z","10000-01-01","1992"],"dc:description":["The subject structure of this study is a two-story historic building and former firehouse located in downtown Gilroy, California. The structure was built in 1890 and it is one of the first URM buildings that has been both instrumented and subjected to a moderate earthquake in U.S. history. Recorded peak ground accelerations were as high as 0.29g and peak roof accelerations as high as 0.79g. Considerable amplifications of the peak accelerations between the ground and the roof were observed. The former firehouse withstood the Loma Prieta Earthquake with little damage.","Unreinforced masonry construction used in Northern California at the turn of this century was similar throughout the United States. Because moderate earthquakes are expected east of the Rocky Mountains, the response of the firehouse can help foretell the earthquake hazard in the eastern and midwestern United States. The ground motions recorded at the firehouse represent an upper bound for assessing possible hazards associated with similarly constructed buildings in the eastern United States. Since the firehouse was not appreciably damaged, even with these high accelerations, there is hope that similar historic buildings across the nation may survive a future earthquake. However, such extrapolation is not warranted unless a detailed investigation is done to examine the reasons for the superior performance.","The objectives of this study are the following: (1) Investigate the reasons of the survival of the firehouse of Gilroy with the use of both simplified and state-of-the-art methods. (2) Present a simplified discrete MDOF dynamic model developed for the seismic evaluation of the firehouse and similar URM buildings with flexible diaphragms. (3) Correlate the recorded, observed and computed response of the firehouse with estimates of dynamic response and prescribed allowable stress limits by state-of-the-art masonry and seismic codes.","Made available in DSpace on 2011-05-07T12:41:37Z (GMT). No. of bitstreams: 2 license.txt: 4922 bytes, checksum: 910b249b4beec47e7ab768910c8f966f (MD5) 9236605.pdf: 16775450 bytes, checksum: 0955946d1e2dc0e91ca2137fbf2f9898 (MD5) Previous issue date: 1992","Item marked as restricted to the 'UIUC Users [automated]' Group (id=2) by Howard Ding (hding2@illinois.edu) on 2011-05-07T14:44:27Z Item is restricted indefinitely.","Restriction data tranferred 2014-07-01T11:19:34-05:00 Original Data Group with Access UIUC Users [automated] Release Date: none Reason: ETDs are only available to UIUC Users without author permission","ETDs are only available to UIUC Users without author permission","U of I Only"],"dc:identifier":["(UMI)AAI9236605","http://hdl.handle.net/2142/20521","AAI9236605"],"dc:language":["eng"],"dc:rights":["Copyright 1992 Tena-Colunga, Arturo"],"dc:subject":["Engineering, Civil"],"dc:title":["Response of an unreinforced masonry building during the Loma Prieta earthquake"],"dc:type":["text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:16Z"}