{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/16166"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/16166","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Using time-independent analysis in optimizing inverter efficiency for grid-connected photovoltaic systems","abstract":"A flexible and computationally effi cient analysis technique for designing and evaluating grid-connected photovoltaic (PV) systems is introduced, which establishes a direct relationship between the inputs to the system, temperature and irradiance, and system performance criteria. For a given year, temperature and irradiance data are rearranged to form a statistical distribution, eliminating thereby the direct time-dependence. The proposed technique decomposes the PV system into three separate layers: an ambient conditions, a PV output, and a dc-ac conversion layer. It reveals important trends, otherwise obscured in the time-dependent view of the data. The time-independent analysis technique is applied to the problem of optimizing inverter e ciency to improve the performance of residential PV systems. A parallel two-inverter con guration is proposed, where one inverter has a small rated power to handle the frequently occurring low-insolation conditions, while the other inverter is large enough to handle the high-insolation regime. The application of this new con guration leads to energy savings as well as e ciency and reliability improvements. A feasibility study taking into account the additional investments required to implement the suggested inverter con guration reveals that applying it under the current electricity prices does not make sense from the economic perspective. However, the two-inverter con guration can become an interesting option in the future as energy prices continue to rise and more nancial incentives for solar systems are introduced.","abstract_html":"A flexible and computationally effi cient analysis technique for designing and evaluating grid-connected photovoltaic (PV) systems is introduced, which establishes a direct relationship between the inputs to the system, temperature and irradiance, and system performance criteria. For a given year, temperature and irradiance data are rearranged to form a statistical distribution, eliminating thereby the direct time-dependence. The proposed technique decomposes the PV system into three separate layers: an ambient conditions, a PV output, and a dc-ac conversion layer. It reveals important trends, otherwise obscured in the time-dependent view of the data. The time-independent analysis technique is applied to the problem of optimizing inverter e ciency to improve the performance of residential PV systems. A parallel two-inverter con guration is proposed, where one inverter has a small rated power to handle the frequently occurring low-insolation conditions, while the other inverter is large enough to handle the high-insolation regime. The application of this new con guration leads to energy savings as well as e ciency and reliability improvements. A feasibility study taking into account the additional investments required to implement the suggested inverter con guration reveals that applying it under the current electricity prices does not make sense from the economic perspective. However, the two-inverter con guration can become an interesting option in the future as energy prices continue to rise and more nancial incentives for solar systems are introduced.","abstract_has_math":false,"creators":["El Bassiouny, Omar A."],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engr","degree_department":null,"school":null,"contributors":["Chapman, Patrick L."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-05-19T18:39:29Z","date_published":"2010-05-19T18:39:29Z","updated_at":"2026-07-22T22:25:08Z","subjects":["photovoltaics","inverter","renewable energy systems","performance","efficiency","modeling","economic feasibility"],"languages":["en"],"rights":["Copyright 2010 Omar A. El Bassiouny"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/16166","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chapman, Patrick L."]},{"key":"dc:creator","label":"Author","values":["El Bassiouny, Omar A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-05-19T18:39:29Z","2010-5"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["photovoltaics","inverter","renewable energy systems","performance","efficiency","modeling","economic feasibility"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2010 Omar A. El Bassiouny"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/16166"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["A flexible and computationally effi cient analysis technique for designing and evaluating grid-connected photovoltaic (PV) systems is introduced, which establishes a direct relationship between the inputs to the system, temperature and irradiance, and system performance criteria. For a given year, temperature and irradiance data are rearranged to form a statistical distribution, eliminating thereby the direct time-dependence. The proposed technique decomposes the PV system into three separate layers: an ambient conditions, a PV output, and a dc-ac conversion layer. It reveals important trends, otherwise obscured in the time-dependent view of the data. The time-independent analysis technique is applied to the problem of optimizing inverter e ciency to improve the performance of residential PV systems. A parallel two-inverter con guration is proposed, where one inverter has a small rated power to handle the frequently occurring low-insolation conditions, while the other inverter is large enough to handle the high-insolation regime. The application of this new con guration leads to energy savings as well as e ciency and reliability improvements. A feasibility study taking into account the additional investments required to implement the suggested inverter con guration reveals that applying it under the current electricity prices does not make sense from the economic perspective. However, the two-inverter con guration can become an interesting option in the future as energy prices continue to rise and more nancial incentives for solar systems are introduced.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2010-04-26T13:52:40Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 3 El Bassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5) omar - MS thesis.tex: 59718 bytes, checksum: 19343f6140bc3c07859217c30ae17fcd (MD5) ElBassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5)","Made available in DSpace on 2010-05-19T18:39:29Z (GMT). No. of bitstreams: 4 El Bassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5) omar - MS thesis.tex: 59718 bytes, checksum: 19343f6140bc3c07859217c30ae17fcd (MD5) ElBassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5) license.txt: 4057 bytes, checksum: 4391048422eb424c975b322c0f6a059b (MD5)"]},{"key":"dc:title","label":"Title","values":["Using time-independent analysis in optimizing inverter efficiency for grid-connected photovoltaic systems"]}]}],"canonical_facts":{"dc:contributor":["Chapman, Patrick L."],"dc:creator":["El Bassiouny, Omar A."],"dc:date":["2010-05-19T18:39:29Z","2010-5"],"dc:description":["A flexible and computationally effi cient analysis technique for designing and evaluating grid-connected photovoltaic (PV) systems is introduced, which establishes a direct relationship between the inputs to the system, temperature and irradiance, and system performance criteria. For a given year, temperature and irradiance data are rearranged to form a statistical distribution, eliminating thereby the direct time-dependence. The proposed technique decomposes the PV system into three separate layers: an ambient conditions, a PV output, and a dc-ac conversion layer. It reveals important trends, otherwise obscured in the time-dependent view of the data. The time-independent analysis technique is applied to the problem of optimizing inverter e ciency to improve the performance of residential PV systems. A parallel two-inverter con guration is proposed, where one inverter has a small rated power to handle the frequently occurring low-insolation conditions, while the other inverter is large enough to handle the high-insolation regime. The application of this new con guration leads to energy savings as well as e ciency and reliability improvements. A feasibility study taking into account the additional investments required to implement the suggested inverter con guration reveals that applying it under the current electricity prices does not make sense from the economic perspective. However, the two-inverter con guration can become an interesting option in the future as energy prices continue to rise and more nancial incentives for solar systems are introduced.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2010-04-26T13:52:40Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 3 El Bassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5) omar - MS thesis.tex: 59718 bytes, checksum: 19343f6140bc3c07859217c30ae17fcd (MD5) ElBassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5)","Made available in DSpace on 2010-05-19T18:39:29Z (GMT). No. of bitstreams: 4 El Bassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5) omar - MS thesis.tex: 59718 bytes, checksum: 19343f6140bc3c07859217c30ae17fcd (MD5) ElBassiouny_Omar.pdf: 964847 bytes, checksum: a02aa37de46eafba0ef661893a0a2035 (MD5) license.txt: 4057 bytes, checksum: 4391048422eb424c975b322c0f6a059b (MD5)"],"dc:identifier":["http://hdl.handle.net/2142/16166"],"dc:language":["en"],"dc:rights":["Copyright 2010 Omar A. El Bassiouny"],"dc:subject":["photovoltaics","inverter","renewable energy systems","performance","efficiency","modeling","economic feasibility"],"dc:title":["Using time-independent analysis in optimizing inverter efficiency for grid-connected photovoltaic systems"],"thesis:degree_discipline":["Electrical & Computer Engr"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:08Z"}