{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/14763"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/14763","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Electrostatically Actuated Microvalves Fabricated with Soft-Lithographic Techniques for Integrated Microfluidics","abstract":"Complex chemical and biological microsystems have the potential to significantly impact point-of-care diagnostics, portable detection systems, and automated, high-throughput chemical processing. The implementation of these systems, however, requires the development of a microvalve that can effectively control connectivity between microfluidic components. Ideally, the valve should be fabricated with simple techniques at low temperature and ambient pressure to facilitate wide dissemination of the technology and also assure effective manufacturability. In addition, the valve should be easily integrated with controls in a portable format. In this work, I report the development of an electrostatic microvalve that is fabricated with simple, soft-lithographic techniques. An analytical model was developed to guide the fabrication process of the microvalves and also optimize the electrical potentials needed to actuate the microvalves. Several methods were investigated for conferring conductivity to elastomeric membranes, including the patterning of nanoparticle/elastomer composites, the airbrushing of conducting nanoparticle suspensions, and the microtransfer printing of nanoparticle films formed by vacuum filtration. The latter was used to integrate the conducting membranes into a fabrication process for microvalves, which included the incorporation of membrane support structures. The fabrication process was optimized by exploring the design space identified by the model, and the optimization yielded microvalves that actuated with electrical potentials as low as 5 V. The potentials required to operate the valve are low enough that the valve can be directly controlled by electrical integrated circuit chips. Finally, I report the pressures that the microvalves can effectively isolate and the actuation of the microvalves in different liquid media, including fluorinated oils and water.","abstract_html":"Complex chemical and biological microsystems have the potential to significantly impact point-of-care diagnostics, portable detection systems, and automated, high-throughput chemical processing. The implementation of these systems, however, requires the development of a microvalve that can effectively control connectivity between microfluidic components. Ideally, the valve should be fabricated with simple techniques at low temperature and ambient pressure to facilitate wide dissemination of the technology and also assure effective manufacturability. In addition, the valve should be easily integrated with controls in a portable format. In this work, I report the development of an electrostatic microvalve that is fabricated with simple, soft-lithographic techniques. An analytical model was developed to guide the fabrication process of the microvalves and also optimize the electrical potentials needed to actuate the microvalves. Several methods were investigated for conferring conductivity to elastomeric membranes, including the patterning of nanoparticle/elastomer composites, the airbrushing of conducting nanoparticle suspensions, and the microtransfer printing of nanoparticle films formed by vacuum filtration. The latter was used to integrate the conducting membranes into a fabrication process for microvalves, which included the incorporation of membrane support structures. The fabrication process was optimized by exploring the design space identified by the model, and the optimization yielded microvalves that actuated with electrical potentials as low as 5 V. The potentials required to operate the valve are low enough that the valve can be directly controlled by electrical integrated circuit chips. Finally, I report the pressures that the microvalves can effectively isolate and the actuation of the microvalves in different liquid media, including fluorinated oils and water.","abstract_has_math":false,"creators":["Tice, Joshua"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Kenis, Paul J.A."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010-01-06T17:50:10Z","date_published":"2010-01-06T17:50:10Z","updated_at":"2026-07-22T22:25:08Z","subjects":["Microvalve","Microfluidic","Soft-Lithography","Microsystem","Electrostatic"],"languages":["en"],"rights":["Copyright 2009 Joshua Tice"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/14763","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kenis, Paul J.A."]},{"key":"dc:creator","label":"Author","values":["Tice, Joshua"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2010-01-06T17:50:10Z","2012-01-07T11:00:12Z","2009-12"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microvalve","Microfluidic","Soft-Lithography","Microsystem","Electrostatic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2009 Joshua Tice"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/14763"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Complex chemical and biological microsystems have the potential to significantly impact point-of-care diagnostics, portable detection systems, and automated, high-throughput chemical processing. The implementation of these systems, however, requires the development of a microvalve that can effectively control connectivity between microfluidic components. Ideally, the valve should be fabricated with simple techniques at low temperature and ambient pressure to facilitate wide dissemination of the technology and also assure effective manufacturability. In addition, the valve should be easily integrated with controls in a portable format. In this work, I report the development of an electrostatic microvalve that is fabricated with simple, soft-lithographic techniques. An analytical model was developed to guide the fabrication process of the microvalves and also optimize the electrical potentials needed to actuate the microvalves. Several methods were investigated for conferring conductivity to elastomeric membranes, including the patterning of nanoparticle/elastomer composites, the airbrushing of conducting nanoparticle suspensions, and the microtransfer printing of nanoparticle films formed by vacuum filtration. The latter was used to integrate the conducting membranes into a fabrication process for microvalves, which included the incorporation of membrane support structures. The fabrication process was optimized by exploring the design space identified by the model, and the optimization yielded microvalves that actuated with electrical potentials as low as 5 V. The potentials required to operate the valve are low enough that the valve can be directly controlled by electrical integrated circuit chips. Finally, I report the pressures that the microvalves can effectively isolate and the actuation of the microvalves in different liquid media, including fluorinated oils and water.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2009-12-10T23:28:17Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 7 Tice_Joshua.pdf: 775812 bytes, checksum: deb7e029ca5e2be1d6b42eb0e4d0e608 (MD5) Tice - Masters thesis - Main text v1.doc: 4748288 bytes, checksum: 71565ad2809f2c861db912aa2cec577d (MD5) Tice - Masters thesis - Table of contents v2.doc: 32256 bytes, checksum: 83ef7ac41696e54696e767534c278e23 (MD5) Tice - Masters thesis - Dedication.doc: 27136 bytes, checksum: da39274434d8514138f8d11ceab853bf (MD5) Tice - Masters thesis - Acknowledgements.doc: 28672 bytes, checksum: 19057d83522cba92cc54fa7c63f1d1a7 (MD5) Tice - Masters thesis - Abstract.doc: 28160 bytes, checksum: 323f4e53428b2254df2376b2db03d57a (MD5) Tice - Masters thesis - Title page v1.doc: 26624 bytes, checksum: 6f90e8c08ef70a9ba14b4f0422f815b2 (MD5)","Made available in DSpace on 2010-01-06T17:50:10Z (GMT). No. of bitstreams: 10 Tice - Masters Thesis - FINAL.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) Tice_Joshua.pdf: 775812 bytes, checksum: deb7e029ca5e2be1d6b42eb0e4d0e608 (MD5) 1_Tice_Joshua.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) license.txt: 4061 bytes, checksum: d0a01eef8885667554a82423420b07db (MD5) Tice - Masters thesis - Main text v1.doc: 4748288 bytes, checksum: 71565ad2809f2c861db912aa2cec577d (MD5) Tice - Masters thesis - Table of contents v2.doc: 32256 bytes, checksum: 83ef7ac41696e54696e767534c278e23 (MD5) Tice - Masters thesis - Dedication.doc: 27136 bytes, checksum: da39274434d8514138f8d11ceab853bf (MD5) Tice - Masters thesis - Acknowledgements.doc: 28672 bytes, checksum: 19057d83522cba92cc54fa7c63f1d1a7 (MD5) Tice - Masters thesis - Abstract.doc: 28160 bytes, checksum: 323f4e53428b2254df2376b2db03d57a (MD5) Tice - Masters thesis - Title page v1.doc: 26624 bytes, checksum: 6f90e8c08ef70a9ba14b4f0422f815b2 (MD5)","Item marked as restricted to the 'Administrator' Group (id=1) by William Ingram (wingram2@illinois.edu) on 2010-01-06T17:50:32Z Item is restricted until 2012-01-06T17:50:31Z","Item reinstated by Sarah Shreeves (sshreeve@illinois.edu) on 2012-01-07T11:00:12Z Item was in collections: Dissertations and Theses - Chemical and Biomolecular Engineering (ID: 591) University of Illinois Dissertations and Theses (ID: 204) No. of bitstreams: 11 1_Tice_Joshua.pdf.txt: 80866 bytes, checksum: ee50ce564411fdcfc6a6ccc5145782e6 (MD5) Tice - Masters Thesis - FINAL.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) Tice_Joshua.pdf: 775812 bytes, checksum: deb7e029ca5e2be1d6b42eb0e4d0e608 (MD5) 1_Tice_Joshua.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) license.txt: 4061 bytes, checksum: d0a01eef8885667554a82423420b07db (MD5) Tice - Masters thesis - Main text v1.doc: 4748288 bytes, checksum: 71565ad2809f2c861db912aa2cec577d (MD5) Tice - Masters thesis - Table of contents v2.doc: 32256 bytes, checksum: 83ef7ac41696e54696e767534c278e23 (MD5) Tice - Masters thesis - Dedication.doc: 27136 bytes, checksum: da39274434d8514138f8d11ceab853bf (MD5) Tice - Masters thesis - Acknowledgements.doc: 28672 bytes, checksum: 19057d83522cba92cc54fa7c63f1d1a7 (MD5) Tice - Masters thesis - Abstract.doc: 28160 bytes, checksum: 323f4e53428b2254df2376b2db03d57a (MD5) Tice - Masters thesis - Title page v1.doc: 26624 bytes, checksum: 6f90e8c08ef70a9ba14b4f0422f815b2 (MD5)","Item released from any restrictions by Sarah Shreeves (sshreeve@illinois.edu) on 2012-01-07T11:00:12Z"]},{"key":"dc:title","label":"Title","values":["Electrostatically Actuated Microvalves Fabricated with Soft-Lithographic Techniques for Integrated Microfluidics"]}]}],"canonical_facts":{"dc:contributor":["Kenis, Paul J.A."],"dc:creator":["Tice, Joshua"],"dc:date":["2010-01-06T17:50:10Z","2012-01-07T11:00:12Z","2009-12"],"dc:description":["Complex chemical and biological microsystems have the potential to significantly impact point-of-care diagnostics, portable detection systems, and automated, high-throughput chemical processing. The implementation of these systems, however, requires the development of a microvalve that can effectively control connectivity between microfluidic components. Ideally, the valve should be fabricated with simple techniques at low temperature and ambient pressure to facilitate wide dissemination of the technology and also assure effective manufacturability. In addition, the valve should be easily integrated with controls in a portable format. In this work, I report the development of an electrostatic microvalve that is fabricated with simple, soft-lithographic techniques. An analytical model was developed to guide the fabrication process of the microvalves and also optimize the electrical potentials needed to actuate the microvalves. Several methods were investigated for conferring conductivity to elastomeric membranes, including the patterning of nanoparticle/elastomer composites, the airbrushing of conducting nanoparticle suspensions, and the microtransfer printing of nanoparticle films formed by vacuum filtration. The latter was used to integrate the conducting membranes into a fabrication process for microvalves, which included the incorporation of membrane support structures. The fabrication process was optimized by exploring the design space identified by the model, and the optimization yielded microvalves that actuated with electrical potentials as low as 5 V. The potentials required to operate the valve are low enough that the valve can be directly controlled by electrical integrated circuit chips. Finally, I report the pressures that the microvalves can effectively isolate and the actuation of the microvalves in different liquid media, including fluorinated oils and water.","Item withdrawn by Mark Zulauf (zulauf@illinois.edu) on 2009-12-10T23:28:17Z Item was in collections: University of Illinois Theses & Dissertations (ID: 1) No. of bitstreams: 7 Tice_Joshua.pdf: 775812 bytes, checksum: deb7e029ca5e2be1d6b42eb0e4d0e608 (MD5) Tice - Masters thesis - Main text v1.doc: 4748288 bytes, checksum: 71565ad2809f2c861db912aa2cec577d (MD5) Tice - Masters thesis - Table of contents v2.doc: 32256 bytes, checksum: 83ef7ac41696e54696e767534c278e23 (MD5) Tice - Masters thesis - Dedication.doc: 27136 bytes, checksum: da39274434d8514138f8d11ceab853bf (MD5) Tice - Masters thesis - Acknowledgements.doc: 28672 bytes, checksum: 19057d83522cba92cc54fa7c63f1d1a7 (MD5) Tice - Masters thesis - Abstract.doc: 28160 bytes, checksum: 323f4e53428b2254df2376b2db03d57a (MD5) Tice - Masters thesis - Title page v1.doc: 26624 bytes, checksum: 6f90e8c08ef70a9ba14b4f0422f815b2 (MD5)","Made available in DSpace on 2010-01-06T17:50:10Z (GMT). No. of bitstreams: 10 Tice - Masters Thesis - FINAL.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) Tice_Joshua.pdf: 775812 bytes, checksum: deb7e029ca5e2be1d6b42eb0e4d0e608 (MD5) 1_Tice_Joshua.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) license.txt: 4061 bytes, checksum: d0a01eef8885667554a82423420b07db (MD5) Tice - Masters thesis - Main text v1.doc: 4748288 bytes, checksum: 71565ad2809f2c861db912aa2cec577d (MD5) Tice - Masters thesis - Table of contents v2.doc: 32256 bytes, checksum: 83ef7ac41696e54696e767534c278e23 (MD5) Tice - Masters thesis - Dedication.doc: 27136 bytes, checksum: da39274434d8514138f8d11ceab853bf (MD5) Tice - Masters thesis - Acknowledgements.doc: 28672 bytes, checksum: 19057d83522cba92cc54fa7c63f1d1a7 (MD5) Tice - Masters thesis - Abstract.doc: 28160 bytes, checksum: 323f4e53428b2254df2376b2db03d57a (MD5) Tice - Masters thesis - Title page v1.doc: 26624 bytes, checksum: 6f90e8c08ef70a9ba14b4f0422f815b2 (MD5)","Item marked as restricted to the 'Administrator' Group (id=1) by William Ingram (wingram2@illinois.edu) on 2010-01-06T17:50:32Z Item is restricted until 2012-01-06T17:50:31Z","Item reinstated by Sarah Shreeves (sshreeve@illinois.edu) on 2012-01-07T11:00:12Z Item was in collections: Dissertations and Theses - Chemical and Biomolecular Engineering (ID: 591) University of Illinois Dissertations and Theses (ID: 204) No. of bitstreams: 11 1_Tice_Joshua.pdf.txt: 80866 bytes, checksum: ee50ce564411fdcfc6a6ccc5145782e6 (MD5) Tice - Masters Thesis - FINAL.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) Tice_Joshua.pdf: 775812 bytes, checksum: deb7e029ca5e2be1d6b42eb0e4d0e608 (MD5) 1_Tice_Joshua.pdf: 772725 bytes, checksum: 5023d56ed6542ce54638ffde20d643d9 (MD5) license.txt: 4061 bytes, checksum: d0a01eef8885667554a82423420b07db (MD5) Tice - Masters thesis - Main text v1.doc: 4748288 bytes, checksum: 71565ad2809f2c861db912aa2cec577d (MD5) Tice - Masters thesis - Table of contents v2.doc: 32256 bytes, checksum: 83ef7ac41696e54696e767534c278e23 (MD5) Tice - Masters thesis - Dedication.doc: 27136 bytes, checksum: da39274434d8514138f8d11ceab853bf (MD5) Tice - Masters thesis - Acknowledgements.doc: 28672 bytes, checksum: 19057d83522cba92cc54fa7c63f1d1a7 (MD5) Tice - Masters thesis - Abstract.doc: 28160 bytes, checksum: 323f4e53428b2254df2376b2db03d57a (MD5) Tice - Masters thesis - Title page v1.doc: 26624 bytes, checksum: 6f90e8c08ef70a9ba14b4f0422f815b2 (MD5)","Item released from any restrictions by Sarah Shreeves (sshreeve@illinois.edu) on 2012-01-07T11:00:12Z"],"dc:identifier":["http://hdl.handle.net/2142/14763"],"dc:language":["en"],"dc:rights":["Copyright 2009 Joshua Tice"],"dc:subject":["Microvalve","Microfluidic","Soft-Lithography","Microsystem","Electrostatic"],"dc:title":["Electrostatically Actuated Microvalves Fabricated with Soft-Lithographic Techniques for Integrated Microfluidics"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:25:08Z"}