{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/115472"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/115472","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Economic analysis of an integrated generator-rectifier system for offshore wind farms","abstract":"Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2022-11-11 without embargo terms","abstract_html":"Submission original under an indefinite embargo labeled &#x27;Open Access&#x27;. The submission was exported from vireo on 2022-11-11 without embargo terms","abstract_has_math":false,"creators":["Mulas Hernando, Daniel"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Electrical & Computer Engr","degree_department":null,"school":null,"contributors":["Sauer, Peter W"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-05","date_published":"2022-05","updated_at":"2026-07-22T22:24:54Z","subjects":["techno-economic analysis","PMSG costs","power electronics costs","operations and maintenance costs","LCOE","offshore wind"],"languages":["en","eng"],"rights":["Copyright 2022 Daniel Mulas Hernando"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/2142/115472","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sauer, Peter W"]},{"key":"dc:creator","label":"Author","values":["Mulas Hernando, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-05","2022-04-17"]},{"key":"dc:type","label":"Dc Type","values":["text","Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical & Computer Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["techno-economic analysis","PMSG costs","power electronics costs","operations and maintenance costs","LCOE","offshore wind"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2022 Daniel Mulas Hernando"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://hdl.handle.net/2142/115472"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2022-11-11 without embargo terms","The student, Daniel Mulas Hernando, accepted the attached license on 2022-04-15 at 19:07.","The student, Daniel Mulas Hernando, submitted this Thesis for approval on 2022-04-15 at 19:25.","This Thesis was approved for publication on 2022-04-17 at 17:14.","DSpace SAF Submission Ingestion Package generated from Vireo submission #17719 on 2022-11-11 at 13:15:28","The existing permanent magnet synchronous generator (PMSG) requires a power electronics (PE) converter that processes the wind turbine's (WT) rated power. A proposed integrated generator-rectifier system that requires 40 % of the WT rated power to be processed by the active rectifier shows an increase in efficiency and reliability, while decreasing the overall system mass and PE costs. The objective of this thesis is to quantify the benefits of incorporating the proposed integrated generator-rectifier system on offshore wind farms by carrying out a comparative techno-economic analysis with respect to the existing design. This techno-economic analysis evaluates the annual energy production and cost components of a single WT and also its extension to an offshore wind farm. A probabilistic model evaluates the uncertainty impacts in the operations and maintenance O&M costs. The efficiency and availability improvements lead to up to 7 % increase in capacity factor, which directly impacts the annual energy production. The marked improvements in reliability lead to 11 % reduction in O&M costs. Consequently, the levelized cost of energy decreases by up to 7 % with respect to the existing design. The techno-economic analysis presented in this thesis provides the basis for a new reference design. In addition, we perform the comparative economic analysis of a wind farm without an offshore substation (OSS) with respect to a wind farm without OSS, both with the incorporation of the proposed integrated generator-rectifier."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Economic analysis of an integrated generator-rectifier system for offshore wind farms"]}]}],"canonical_facts":{"dc:contributor":["Sauer, Peter W"],"dc:creator":["Mulas Hernando, Daniel"],"dc:date":["2022-05","2022-04-17"],"dc:description":["Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2022-11-11 without embargo terms","The student, Daniel Mulas Hernando, accepted the attached license on 2022-04-15 at 19:07.","The student, Daniel Mulas Hernando, submitted this Thesis for approval on 2022-04-15 at 19:25.","This Thesis was approved for publication on 2022-04-17 at 17:14.","DSpace SAF Submission Ingestion Package generated from Vireo submission #17719 on 2022-11-11 at 13:15:28","The existing permanent magnet synchronous generator (PMSG) requires a power electronics (PE) converter that processes the wind turbine's (WT) rated power. A proposed integrated generator-rectifier system that requires 40 % of the WT rated power to be processed by the active rectifier shows an increase in efficiency and reliability, while decreasing the overall system mass and PE costs. The objective of this thesis is to quantify the benefits of incorporating the proposed integrated generator-rectifier system on offshore wind farms by carrying out a comparative techno-economic analysis with respect to the existing design. This techno-economic analysis evaluates the annual energy production and cost components of a single WT and also its extension to an offshore wind farm. A probabilistic model evaluates the uncertainty impacts in the operations and maintenance O&M costs. The efficiency and availability improvements lead to up to 7 % increase in capacity factor, which directly impacts the annual energy production. The marked improvements in reliability lead to 11 % reduction in O&M costs. Consequently, the levelized cost of energy decreases by up to 7 % with respect to the existing design. The techno-economic analysis presented in this thesis provides the basis for a new reference design. In addition, we perform the comparative economic analysis of a wind farm without an offshore substation (OSS) with respect to a wind farm without OSS, both with the incorporation of the proposed integrated generator-rectifier."],"dc:format":["application/pdf"],"dc:identifier":["https://hdl.handle.net/2142/115472"],"dc:language":["en","eng"],"dc:rights":["Copyright 2022 Daniel Mulas Hernando"],"dc:subject":["techno-economic analysis","PMSG costs","power electronics costs","operations and maintenance costs","LCOE","offshore wind"],"dc:title":["Economic analysis of an integrated generator-rectifier system for offshore wind farms"],"dc:type":["text","Thesis"],"thesis:degree_discipline":["Electrical & Computer Engr"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:24:54Z"}