{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/110505"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/110505","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Changes of voice production in artificial acoustic environments","abstract":"The physical production of speech level dynamic range is directly affected by the physiological features of the speaker such as vocal tract size and lung capacity. However, the regulation of these production systems is affected by the perception of the communication environment and auditory feedback. The current study examined the effects of room acoustics in an artificial setting on voice production in terms of sound pressure level and the relationship with the perceived voice comfort and voice control. Three independent room acoustic parameters were considered: gain (alteration of the sidetone or playback of one's own voice), reverberation time and background noise. An increase in the sidetone led to a decrease in voice sound pressure levels, thus increasing voice comfort and voice control. This effect was consistent in different reverberation times considered. Mid-range reverberation times (T30≈1.3 seconds) led to a decrease in voice sound pressure level along with an increase in voice comfort and voice control, however the effect of the reverberation time was smaller than the effect of the gain. The presence of noise amplified the aforementioned effects for the analyzed variables.","abstract_html":"The physical production of speech level dynamic range is directly affected by the physiological features of the speaker such as vocal tract size and lung capacity. However, the regulation of these production systems is affected by the perception of the communication environment and auditory feedback. The current study examined the effects of room acoustics in an artificial setting on voice production in terms of sound pressure level and the relationship with the perceived voice comfort and voice control. Three independent room acoustic parameters were considered: gain (alteration of the sidetone or playback of one&#x27;s own voice), reverberation time and background noise. An increase in the sidetone led to a decrease in voice sound pressure levels, thus increasing voice comfort and voice control. This effect was consistent in different reverberation times considered. Mid-range reverberation times (T30≈1.3 seconds) led to a decrease in voice sound pressure level along with an increase in voice comfort and voice control, however the effect of the reverberation time was smaller than the effect of the gain. The presence of noise amplified the aforementioned effects for the analyzed variables.","abstract_has_math":false,"creators":["Sierra Polanco, Tomas Enrique"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.A.","degree_level":"Thesis","degree_discipline":"Speech & Hearing Science","degree_department":null,"school":null,"contributors":["Bottalico, Pasquale","Husain, Fatima","Ishikawa, Keiko"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-09-17T01:11:04Z","date_published":"2021-09-17T01:11:04Z","updated_at":"2026-07-22T22:24:50Z","subjects":["Room acoustics","gain","background noise","reverberation time","speech level","vocal comfort","vocal control."],"languages":["en"],"rights":["Copyright 2021 Tomás Sierra"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/110505","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bottalico, Pasquale","Husain, Fatima","Ishikawa, Keiko"]},{"key":"dc:creator","label":"Author","values":["Sierra Polanco, Tomas Enrique"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-09-17T01:11:04Z","2021-04-23","2021-05"]},{"key":"dc:type","label":"Dc Type","values":["text","Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Speech & Hearing Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.A."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Room acoustics","gain","background noise","reverberation time","speech level","vocal comfort","vocal control."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2021 Tomás Sierra"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/110505"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The physical production of speech level dynamic range is directly affected by the physiological features of the speaker such as vocal tract size and lung capacity. However, the regulation of these production systems is affected by the perception of the communication environment and auditory feedback. The current study examined the effects of room acoustics in an artificial setting on voice production in terms of sound pressure level and the relationship with the perceived voice comfort and voice control. Three independent room acoustic parameters were considered: gain (alteration of the sidetone or playback of one's own voice), reverberation time and background noise. An increase in the sidetone led to a decrease in voice sound pressure levels, thus increasing voice comfort and voice control. This effect was consistent in different reverberation times considered. Mid-range reverberation times (T30≈1.3 seconds) led to a decrease in voice sound pressure level along with an increase in voice comfort and voice control, however the effect of the reverberation time was smaller than the effect of the gain. The presence of noise amplified the aforementioned effects for the analyzed variables.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2021-09-16 without embargo terms","The student, Tomas Sierra Polanco, accepted the attached license on 2021-04-19 at 14:57.","The student, Tomas Sierra Polanco, submitted this Thesis for approval on 2021-04-19 at 15:14.","This Thesis was approved for publication on 2021-04-23 at 13:32.","DSpace SAF Submission Ingestion Package generated from Vireo submission #16416 on 2021-09-16 at 16:43:24","Made available in DSpace on 2021-09-17T01:11:04Z (GMT). No. of bitstreams: 2 SIERRAPOLANCO-THESIS-2021.pdf: 600352 bytes, checksum: c7456329c2844f40c3a1666736c06792 (MD5) LICENSE.txt: 4209 bytes, checksum: 04b4debfc643ac017392da2311619420 (MD5) Previous issue date: 2021-04-23"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Changes of voice production in artificial acoustic environments"]}]}],"canonical_facts":{"dc:contributor":["Bottalico, Pasquale","Husain, Fatima","Ishikawa, Keiko"],"dc:creator":["Sierra Polanco, Tomas Enrique"],"dc:date":["2021-09-17T01:11:04Z","2021-04-23","2021-05"],"dc:description":["The physical production of speech level dynamic range is directly affected by the physiological features of the speaker such as vocal tract size and lung capacity. However, the regulation of these production systems is affected by the perception of the communication environment and auditory feedback. The current study examined the effects of room acoustics in an artificial setting on voice production in terms of sound pressure level and the relationship with the perceived voice comfort and voice control. Three independent room acoustic parameters were considered: gain (alteration of the sidetone or playback of one's own voice), reverberation time and background noise. An increase in the sidetone led to a decrease in voice sound pressure levels, thus increasing voice comfort and voice control. This effect was consistent in different reverberation times considered. Mid-range reverberation times (T30≈1.3 seconds) led to a decrease in voice sound pressure level along with an increase in voice comfort and voice control, however the effect of the reverberation time was smaller than the effect of the gain. The presence of noise amplified the aforementioned effects for the analyzed variables.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2021-09-16 without embargo terms","The student, Tomas Sierra Polanco, accepted the attached license on 2021-04-19 at 14:57.","The student, Tomas Sierra Polanco, submitted this Thesis for approval on 2021-04-19 at 15:14.","This Thesis was approved for publication on 2021-04-23 at 13:32.","DSpace SAF Submission Ingestion Package generated from Vireo submission #16416 on 2021-09-16 at 16:43:24","Made available in DSpace on 2021-09-17T01:11:04Z (GMT). No. of bitstreams: 2 SIERRAPOLANCO-THESIS-2021.pdf: 600352 bytes, checksum: c7456329c2844f40c3a1666736c06792 (MD5) LICENSE.txt: 4209 bytes, checksum: 04b4debfc643ac017392da2311619420 (MD5) Previous issue date: 2021-04-23"],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/2142/110505"],"dc:language":["en"],"dc:rights":["Copyright 2021 Tomás Sierra"],"dc:subject":["Room acoustics","gain","background noise","reverberation time","speech level","vocal comfort","vocal control."],"dc:title":["Changes of voice production in artificial acoustic environments"],"dc:type":["text","Thesis"],"thesis:degree_discipline":["Speech & Hearing Science"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.A."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:24:50Z"}