{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/106335"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/106335","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"A novel inertial measurement unit-based device for capturing upper extremity biomechanics","abstract":"The student, Andrew Hua, submitted this Dissertation for approval on 2019-10-31 at 10:21.","abstract_html":"The student, Andrew Hua, submitted this Dissertation for approval on 2019-10-31 at 10:21.","abstract_has_math":false,"creators":["Hua, Andrew"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Kinesiology","degree_department":null,"school":null,"contributors":["Hernandez, Manuel E","Buchner, David","Jan, Yih-Kuen","Schatz, Bruce"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-03-02T22:12:15Z","date_published":"2020-03-02T22:12:15Z","updated_at":"2026-07-22T22:24:45Z","subjects":["biomechanics","rehabilitation","physical therapy","exercise classification","inertial measurement units","wearable","healthcare","inertial measurement unit"],"languages":["en"],"rights":["Copyright 2019 Andrew Hua"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/106335","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hernandez, Manuel E","Buchner, David","Jan, Yih-Kuen","Schatz, Bruce"]},{"key":"dc:creator","label":"Author","values":["Hua, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-03-02T22:12:15Z","2022-03-03T10:15:30Z","2019-11-01","2019-12"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Kinesiology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biomechanics","rehabilitation","physical therapy","exercise classification","inertial measurement units","wearable","healthcare","inertial measurement unit"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2019 Andrew Hua"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/106335"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The student, Andrew Hua, submitted this Dissertation for approval on 2019-10-31 at 10:21.","This Dissertation was approved for publication on 2019-11-01 at 15:42.","DSpace SAF Submission Ingestion Package generated from Vireo submission #14525 on 2020-02-28 at 17:21:46","Exercise adherence can be poor for patients in physical therapy (PT). Unsupervised exercise may contribute to poor adherence as patients may have low exercise self-efficacy, feel unmotivated, or simply do not perform exercises correctly. This dissertation proposes a cheap wearable device that utilizes inertial measurement units (IMUs) to capture kinematics during upper extremity (UE) exercises. The first aim of this study was to identify key ergonomic and graphic features that would likely improve device adoption and assess participant receptiveness towards the device. The second aim was to validate the device against marker-based motion capture using traditional validation techniques and trend symmetry analysis (TSA). The third aim was to evaluate machine learning models for classifying nine different upper extremity exercises, based upon kinematic data captured from an IMU-based device. 50 participants were recruited to perform nine common UE exercises with the device. Joint angles were calculated for the shoulder, elbow, and wrist. Participants were given an orientation to the device and shown conceptual software graphics. Participants responded positively to the device and graphics but found the device bulky and cumbersome. Participants were able to interpret kinematic analysis despite having limited biomechanics knowledge. Device range of motion (ROM) measures were most accurate for sagittal and frontal plane measures (ROM measure differences ranged from 3.3°-18.6°) with worse performance on transverse plane movements (ROM measure differences ranged from 6.0°-60.8°). TSA scores were high (mean = 0.956) even when ROM agreement was low. TSA shows promise as a validation technique, but additional research is needed to establish cut points to define “good” TSA results. UE exercises could be classified with accuracy as high as 98.6% using random forest models using flattened kinematic data. Down sampling had minimal impact on classifier performance (precision = 0.952, 5 Hz). Accuracy remained greater than 90% when training splits were decreased to 10%. Classifier performance decreased (96% accuracy with 90% training split) when using stratified train-test splits, and overtraining may pose a problem with small samples. The findings of this research can provide guidance on the design of future wearables to augment PT and development of a revised device and companion smartphone application for clinical testing.","Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2021-12-01","The student, Andrew Hua, accepted the attached license on 2019-10-31 at 09:50.","Made available in DSpace on 2020-03-02T22:12:15Z (GMT). No. of bitstreams: 3 HUA-DISSERTATION-2019.pdf: 997588 bytes, checksum: 0cdbe8c032c2704c2f8b16f1117f3940 (MD5) LICENSE.txt: 4207 bytes, checksum: 4ecec2aa5f5bf13dac34ad1a30128d0b (MD5) PROQUEST_LICENSE.txt: 4553 bytes, checksum: ef960781971ea909f193f4cccf0600c4 (MD5) Previous issue date: 2019-11-01","Embargo set by: Seth Robbins for item 113876 Lift date: 2022-03-02T22:12:26Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Embargo set by: Seth Robbins for item 113876 Lift date: 2022-03-02T22:15:21Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Embargo set by: Seth Robbins for item 113876 Lift date: 2022-03-02T22:18:25Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","U of I Only Restriction Lifted for Item 113876 on 2022-03-03T10:15:30Z."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A novel inertial measurement unit-based device for capturing upper extremity biomechanics"]}]}],"canonical_facts":{"dc:contributor":["Hernandez, Manuel E","Buchner, David","Jan, Yih-Kuen","Schatz, Bruce"],"dc:creator":["Hua, Andrew"],"dc:date":["2020-03-02T22:12:15Z","2022-03-03T10:15:30Z","2019-11-01","2019-12"],"dc:description":["The student, Andrew Hua, submitted this Dissertation for approval on 2019-10-31 at 10:21.","This Dissertation was approved for publication on 2019-11-01 at 15:42.","DSpace SAF Submission Ingestion Package generated from Vireo submission #14525 on 2020-02-28 at 17:21:46","Exercise adherence can be poor for patients in physical therapy (PT). Unsupervised exercise may contribute to poor adherence as patients may have low exercise self-efficacy, feel unmotivated, or simply do not perform exercises correctly. This dissertation proposes a cheap wearable device that utilizes inertial measurement units (IMUs) to capture kinematics during upper extremity (UE) exercises. The first aim of this study was to identify key ergonomic and graphic features that would likely improve device adoption and assess participant receptiveness towards the device. The second aim was to validate the device against marker-based motion capture using traditional validation techniques and trend symmetry analysis (TSA). The third aim was to evaluate machine learning models for classifying nine different upper extremity exercises, based upon kinematic data captured from an IMU-based device. 50 participants were recruited to perform nine common UE exercises with the device. Joint angles were calculated for the shoulder, elbow, and wrist. Participants were given an orientation to the device and shown conceptual software graphics. Participants responded positively to the device and graphics but found the device bulky and cumbersome. Participants were able to interpret kinematic analysis despite having limited biomechanics knowledge. Device range of motion (ROM) measures were most accurate for sagittal and frontal plane measures (ROM measure differences ranged from 3.3°-18.6°) with worse performance on transverse plane movements (ROM measure differences ranged from 6.0°-60.8°). TSA scores were high (mean = 0.956) even when ROM agreement was low. TSA shows promise as a validation technique, but additional research is needed to establish cut points to define “good” TSA results. UE exercises could be classified with accuracy as high as 98.6% using random forest models using flattened kinematic data. Down sampling had minimal impact on classifier performance (precision = 0.952, 5 Hz). Accuracy remained greater than 90% when training splits were decreased to 10%. Classifier performance decreased (96% accuracy with 90% training split) when using stratified train-test splits, and overtraining may pose a problem with small samples. The findings of this research can provide guidance on the design of future wearables to augment PT and development of a revised device and companion smartphone application for clinical testing.","Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2021-12-01","The student, Andrew Hua, accepted the attached license on 2019-10-31 at 09:50.","Made available in DSpace on 2020-03-02T22:12:15Z (GMT). No. of bitstreams: 3 HUA-DISSERTATION-2019.pdf: 997588 bytes, checksum: 0cdbe8c032c2704c2f8b16f1117f3940 (MD5) LICENSE.txt: 4207 bytes, checksum: 4ecec2aa5f5bf13dac34ad1a30128d0b (MD5) PROQUEST_LICENSE.txt: 4553 bytes, checksum: ef960781971ea909f193f4cccf0600c4 (MD5) Previous issue date: 2019-11-01","Embargo set by: Seth Robbins for item 113876 Lift date: 2022-03-02T22:12:26Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Embargo set by: Seth Robbins for item 113876 Lift date: 2022-03-02T22:15:21Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","Embargo set by: Seth Robbins for item 113876 Lift date: 2022-03-02T22:18:25Z Reason: Author requested U of Illinois access only (OA after 2yrs) in Vireo ETD system","U of I Only Restriction Lifted for Item 113876 on 2022-03-03T10:15:30Z."],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/2142/106335"],"dc:language":["en"],"dc:rights":["Copyright 2019 Andrew Hua"],"dc:subject":["biomechanics","rehabilitation","physical therapy","exercise classification","inertial measurement units","wearable","healthcare","inertial measurement unit"],"dc:title":["A novel inertial measurement unit-based device for capturing upper extremity biomechanics"],"dc:type":["text"],"thesis:degree_discipline":["Kinesiology"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:24:45Z"}