{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/101586"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/101586","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Design study of a two-panel head-and-neck cancer dedicated position emission tomography system","abstract":"Head and neck cancer (HNC) is collectively a group of cancers that usually begin in mucosal surfaces inside the head and neck. Due to the complex anatomy and vital physiological role of the tumor-involved regions, the goal of HNC treatment is not only to improve survival outcomes but also to preserve organ function. Whole-body (WB) positron emission tomography (PET) has been widely used for HNC diagnosis and treatment, but its low spatial resolution limits the management of HNC. A higher spatial resolution and a better contrast image will allow radiation oncologists to accurately measure the boundaries of tumors, design the planned target volume dose, and thus offer more freedom to choose treatment options such as surgery, radiation therapy, chemotherapy and targeted therapy. To achieve a better management of HNC, this dissertation proposes a HNC dedicated PET system, which is supposed to replace the dedicated protocol in hospitals. The performance of a proposed system is studied using a Monte Carlo simulation. The noise equivalent count rate of the dedicated system is 9.3 kcps at 5.7 kBq/cm3, and it increases to 10.5 kcps at 5.7 kBq/cm3 with a lead shielding. The photon sensitivity is 0.83% for a point source placed at the field of view (FOV) center. With a 2-mm full width at half maximum (FWHM) depth-of-interaction resolution, the system achieves 1 mm orthogonal-panel and 1.5 mm parallel-panel spatial resolution, and a 2-mm diameter hot rod is visible. Multiple scattering events are recovered and the entire FOV has a relatively uniform improvement of sensitivity. Signal- to-noise ratio and contrast-to-noise ratio of the reconstructed image improve 41.4% and 29.2% respectively after incorporating recovered multiple scattering events. Compared with a commercial WB PET system (GE Discovery MI), the proposed dedicated system shows an 830% improvement of noise equivalent count rate, a 36.1% improvement of photon coincidence sensitivity and a better spatial resolution and lesion visualization capability. Further hardware-level work such as detector module design and characterization are on-going to validate these initial results.","abstract_html":"Head and neck cancer (HNC) is collectively a group of cancers that usually begin in mucosal surfaces inside the head and neck. Due to the complex anatomy and vital physiological role of the tumor-involved regions, the goal of HNC treatment is not only to improve survival outcomes but also to preserve organ function. Whole-body (WB) positron emission tomography (PET) has been widely used for HNC diagnosis and treatment, but its low spatial resolution limits the management of HNC. A higher spatial resolution and a better contrast image will allow radiation oncologists to accurately measure the boundaries of tumors, design the planned target volume dose, and thus offer more freedom to choose treatment options such as surgery, radiation therapy, chemotherapy and targeted therapy. To achieve a better management of HNC, this dissertation proposes a HNC dedicated PET system, which is supposed to replace the dedicated protocol in hospitals. The performance of a proposed system is studied using a Monte Carlo simulation. The noise equivalent count rate of the dedicated system is 9.3 kcps at 5.7 kBq/cm3, and it increases to 10.5 kcps at 5.7 kBq/cm3 with a lead shielding. The photon sensitivity is 0.83% for a point source placed at the field of view (FOV) center. With a 2-mm full width at half maximum (FWHM) depth-of-interaction resolution, the system achieves 1 mm orthogonal-panel and 1.5 mm parallel-panel spatial resolution, and a 2-mm diameter hot rod is visible. Multiple scattering events are recovered and the entire FOV has a relatively uniform improvement of sensitivity. Signal- to-noise ratio and contrast-to-noise ratio of the reconstructed image improve 41.4% and 29.2% respectively after incorporating recovered multiple scattering events. Compared with a commercial WB PET system (GE Discovery MI), the proposed dedicated system shows an 830% improvement of noise equivalent count rate, a 36.1% improvement of photon coincidence sensitivity and a better spatial resolution and lesion visualization capability. Further hardware-level work such as detector module design and characterization are on-going to validate these initial results.","abstract_has_math":false,"creators":["Li, Mohan"],"institution":"University of Illinois at Urbana-Champaign","degree_name":"M.S.","degree_level":"Thesis","degree_discipline":"Nuclear, Plasma, Radiolgc Engr","degree_department":null,"school":null,"contributors":["Abbaszadeh, Shiva","Uddin, Rizwan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-09-27T16:17:53Z","date_published":"2018-09-27T16:17:53Z","updated_at":"2026-07-22T22:24:40Z","subjects":["positron emission tomography","head-and-neck cancer","organ specific"],"languages":["en"],"rights":["Copyright 2018 Mohan Li"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/101586","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Abbaszadeh, Shiva","Uddin, Rizwan"]},{"key":"dc:creator","label":"Author","values":["Li, Mohan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-09-27T16:17:53Z","2018-07-16","2018-08"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Nuclear, Plasma, Radiolgc Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["positron emission tomography","head-and-neck cancer","organ specific"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2018 Mohan Li"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/101586"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Head and neck cancer (HNC) is collectively a group of cancers that usually begin in mucosal surfaces inside the head and neck. Due to the complex anatomy and vital physiological role of the tumor-involved regions, the goal of HNC treatment is not only to improve survival outcomes but also to preserve organ function. Whole-body (WB) positron emission tomography (PET) has been widely used for HNC diagnosis and treatment, but its low spatial resolution limits the management of HNC. A higher spatial resolution and a better contrast image will allow radiation oncologists to accurately measure the boundaries of tumors, design the planned target volume dose, and thus offer more freedom to choose treatment options such as surgery, radiation therapy, chemotherapy and targeted therapy. To achieve a better management of HNC, this dissertation proposes a HNC dedicated PET system, which is supposed to replace the dedicated protocol in hospitals. The performance of a proposed system is studied using a Monte Carlo simulation. The noise equivalent count rate of the dedicated system is 9.3 kcps at 5.7 kBq/cm3, and it increases to 10.5 kcps at 5.7 kBq/cm3 with a lead shielding. The photon sensitivity is 0.83% for a point source placed at the field of view (FOV) center. With a 2-mm full width at half maximum (FWHM) depth-of-interaction resolution, the system achieves 1 mm orthogonal-panel and 1.5 mm parallel-panel spatial resolution, and a 2-mm diameter hot rod is visible. Multiple scattering events are recovered and the entire FOV has a relatively uniform improvement of sensitivity. Signal- to-noise ratio and contrast-to-noise ratio of the reconstructed image improve 41.4% and 29.2% respectively after incorporating recovered multiple scattering events. Compared with a commercial WB PET system (GE Discovery MI), the proposed dedicated system shows an 830% improvement of noise equivalent count rate, a 36.1% improvement of photon coincidence sensitivity and a better spatial resolution and lesion visualization capability. Further hardware-level work such as detector module design and characterization are on-going to validate these initial results.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2018-09-27 without embargo terms","The student, Mohan Li, accepted the attached license on 2018-07-14 at 02:33.","The student, Mohan Li, submitted this Thesis for approval on 2018-07-14 at 02:55.","This Thesis was approved for publication on 2018-07-16 at 10:56.","DSpace SAF Submission Ingestion Package generated from Vireo submission #12877 on 2018-09-27 at 10:48:33","Made available in DSpace on 2018-09-27T16:17:53Z (GMT). No. of bitstreams: 3 LI-THESIS-2018.pdf: 4581792 bytes, checksum: 1436d88842778ff563ebe820ffbdc3bf (MD5) source.zip: 5300570 bytes, checksum: 6b7f291ed090e19050082170b4801841 (MD5) LICENSE.txt: 4205 bytes, checksum: a7aedf9a26d3c14b971f2dbced0530fa (MD5) Previous issue date: 2018-07-16"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design study of a two-panel head-and-neck cancer dedicated position emission tomography system"]}]}],"canonical_facts":{"dc:contributor":["Abbaszadeh, Shiva","Uddin, Rizwan"],"dc:creator":["Li, Mohan"],"dc:date":["2018-09-27T16:17:53Z","2018-07-16","2018-08"],"dc:description":["Head and neck cancer (HNC) is collectively a group of cancers that usually begin in mucosal surfaces inside the head and neck. Due to the complex anatomy and vital physiological role of the tumor-involved regions, the goal of HNC treatment is not only to improve survival outcomes but also to preserve organ function. Whole-body (WB) positron emission tomography (PET) has been widely used for HNC diagnosis and treatment, but its low spatial resolution limits the management of HNC. A higher spatial resolution and a better contrast image will allow radiation oncologists to accurately measure the boundaries of tumors, design the planned target volume dose, and thus offer more freedom to choose treatment options such as surgery, radiation therapy, chemotherapy and targeted therapy. To achieve a better management of HNC, this dissertation proposes a HNC dedicated PET system, which is supposed to replace the dedicated protocol in hospitals. The performance of a proposed system is studied using a Monte Carlo simulation. The noise equivalent count rate of the dedicated system is 9.3 kcps at 5.7 kBq/cm3, and it increases to 10.5 kcps at 5.7 kBq/cm3 with a lead shielding. The photon sensitivity is 0.83% for a point source placed at the field of view (FOV) center. With a 2-mm full width at half maximum (FWHM) depth-of-interaction resolution, the system achieves 1 mm orthogonal-panel and 1.5 mm parallel-panel spatial resolution, and a 2-mm diameter hot rod is visible. Multiple scattering events are recovered and the entire FOV has a relatively uniform improvement of sensitivity. Signal- to-noise ratio and contrast-to-noise ratio of the reconstructed image improve 41.4% and 29.2% respectively after incorporating recovered multiple scattering events. Compared with a commercial WB PET system (GE Discovery MI), the proposed dedicated system shows an 830% improvement of noise equivalent count rate, a 36.1% improvement of photon coincidence sensitivity and a better spatial resolution and lesion visualization capability. Further hardware-level work such as detector module design and characterization are on-going to validate these initial results.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2018-09-27 without embargo terms","The student, Mohan Li, accepted the attached license on 2018-07-14 at 02:33.","The student, Mohan Li, submitted this Thesis for approval on 2018-07-14 at 02:55.","This Thesis was approved for publication on 2018-07-16 at 10:56.","DSpace SAF Submission Ingestion Package generated from Vireo submission #12877 on 2018-09-27 at 10:48:33","Made available in DSpace on 2018-09-27T16:17:53Z (GMT). No. of bitstreams: 3 LI-THESIS-2018.pdf: 4581792 bytes, checksum: 1436d88842778ff563ebe820ffbdc3bf (MD5) source.zip: 5300570 bytes, checksum: 6b7f291ed090e19050082170b4801841 (MD5) LICENSE.txt: 4205 bytes, checksum: a7aedf9a26d3c14b971f2dbced0530fa (MD5) Previous issue date: 2018-07-16"],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/2142/101586"],"dc:language":["en"],"dc:rights":["Copyright 2018 Mohan Li"],"dc:subject":["positron emission tomography","head-and-neck cancer","organ specific"],"dc:title":["Design study of a two-panel head-and-neck cancer dedicated position emission tomography system"],"dc:type":["text"],"thesis:degree_discipline":["Nuclear, Plasma, Radiolgc Engr"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["M.S."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:24:40Z"}