{"id":{"repo_id":"uiuc","oai_identifier":"oai:www.ideals.illinois.edu:2142/100908"},"canonical_url":"https://search.dev.ndltd.org/etd/uiuc/oai:www.ideals.illinois.edu:2142/100908","repository":{"repo_id":"uiuc","name":"University of Illinois - Urbana-Champaign","base_url":"https://www.ideals.illinois.edu/oai-pmh"},"display":{"title":"Limits on subcritical reactivity determination using rossi-alpha and related methods","abstract":"The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/235U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$ and 70$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (k-code) mode in MCNP R6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossiα method. The measurements are taken using a 3He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is −199.4±4.4 s−1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be −8.5 × 10−5 s−1. The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when keff > 0.80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.","abstract_html":"The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/235U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$ and 70$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (k-code) mode in MCNP R6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossiα method. The measurements are taken using a 3He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is −199.4±4.4 s−1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be −8.5 × 10−5 s−1. The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when keff &gt; 0.80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.","abstract_has_math":false,"creators":["McKenzie, George E."],"institution":"University of Illinois at Urbana-Champaign","degree_name":"Ph.D.","degree_level":"Dissertation","degree_discipline":"Nuclear, Plasma, Radiolgc Engr","degree_department":null,"school":null,"contributors":["Kozlowski, Tomasz","Perdekamp, Matthias","Stubbins, James","Uddin, Rizwan","Myers, William"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018-09-04T20:26:42Z","date_published":"2018-09-04T20:26:42Z","updated_at":"2026-07-22T22:24:38Z","subjects":["Rossi-alpha, neutron noise, critical experiment, subcritical reactivity"],"languages":["en"],"rights":["Copyright 2018 George McKenzie"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2142/100908","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kozlowski, Tomasz","Perdekamp, Matthias","Stubbins, James","Uddin, Rizwan","Myers, William"]},{"key":"dc:creator","label":"Author","values":["McKenzie, George E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018-09-04T20:26:42Z","2018-03-13","2018-05"]},{"key":"dc:type","label":"Dc Type","values":["text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Nuclear, Plasma, Radiolgc Engr"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph.D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Illinois at Urbana-Champaign"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Rossi-alpha, neutron noise, critical experiment, subcritical reactivity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright 2018 George McKenzie"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2142/100908"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/235U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$ and 70$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (k-code) mode in MCNP R6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossiα method. The measurements are taken using a 3He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is −199.4±4.4 s−1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be −8.5 × 10−5 s−1. The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when keff > 0.80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2018-08-31 without embargo terms","The student, George McKenzie, accepted the attached license on 2018-03-13 at 14:42.","The student, George McKenzie, submitted this Dissertation for approval on 2018-03-13 at 15:14.","This Dissertation was approved for publication on 2018-03-13 at 16:21.","DSpace SAF Submission Ingestion Package generated from Vireo submission #12066 on 2018-08-31 at 17:09:35","Made available in DSpace on 2018-09-04T20:26:42Z (GMT). No. of bitstreams: 18 MCKENZIE-DISSERTATION-2018.pdf: 37028130 bytes, checksum: 67b64a6b472bffc9c4b419646b1c1008 (MD5) IEEE_ECE.bst: 61899 bytes, checksum: 7509566d10f8075f0fad3df817415508 (MD5) PhD_Thesis.tex: 7207 bytes, checksum: 732628870059aaac31bee0c4612d62d8 (MD5) abs.tex: 2078 bytes, checksum: 3bca1fe8ed94c16a697b951d6ee6a6e7 (MD5) ack.tex: 2908 bytes, checksum: d097d5ca4df9c0fba65f1d6e5f4f3bf9 (MD5) appendix.tex: 31201 bytes, checksum: 8f50a57be3a4fbf6ea2cfe3a6e43258b (MD5) computational.tex: 18025 bytes, checksum: e48aa0fa41a5a5552f47efc34fbbc730 (MD5) concl.tex: 6445 bytes, checksum: 2be15460f92d72baddc636c2a0feb5cb (MD5) experiment.tex: 36112 bytes, checksum: fe2e968da19d0e3c9cc53340d111aa4c (MD5) images.zip: 140215374 bytes, checksum: 8d841fb475ac9f5957d0c90e125a8bd1 (MD5) intro.tex: 28542 bytes, checksum: 8d7400ef051f41e16b3532cbf7035cea (MD5) reactor_kinetics.tex: 31362 bytes, checksum: b0757e478127bfddbd1534216e17cc82 (MD5) results.tex: 30796 bytes, checksum: 7a453b786dae1767a71914304b3f15ed (MD5) thesisrefs.bib: 33541 bytes, checksum: 3c6ba685e4d0458948c1f6896612af42 (MD5) uiucecethesis09.cls: 22309 bytes, checksum: dbfcb6ce43781de390491449cbb14480 (MD5) uncertainty.tex: 18520 bytes, checksum: 0c15909247653c9f1bbde367fc960c77 (MD5) LICENSE.txt: 4212 bytes, checksum: 6df9dad181ad1892d1975835e25c7381 (MD5) PROQUEST_LICENSE.txt: 4558 bytes, checksum: 425f156bfaed61350e9aa6f1befc36a9 (MD5) Previous issue date: 2018-03-13"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Limits on subcritical reactivity determination using rossi-alpha and related methods"]}]}],"canonical_facts":{"dc:contributor":["Kozlowski, Tomasz","Perdekamp, Matthias","Stubbins, James","Uddin, Rizwan","Myers, William"],"dc:creator":["McKenzie, George E."],"dc:date":["2018-09-04T20:26:42Z","2018-03-13","2018-05"],"dc:description":["The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/235U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$ and 70$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (k-code) mode in MCNP R6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossiα method. The measurements are taken using a 3He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is −199.4±4.4 s−1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be −8.5 × 10−5 s−1. The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when keff > 0.80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.","Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2018-08-31 without embargo terms","The student, George McKenzie, accepted the attached license on 2018-03-13 at 14:42.","The student, George McKenzie, submitted this Dissertation for approval on 2018-03-13 at 15:14.","This Dissertation was approved for publication on 2018-03-13 at 16:21.","DSpace SAF Submission Ingestion Package generated from Vireo submission #12066 on 2018-08-31 at 17:09:35","Made available in DSpace on 2018-09-04T20:26:42Z (GMT). No. of bitstreams: 18 MCKENZIE-DISSERTATION-2018.pdf: 37028130 bytes, checksum: 67b64a6b472bffc9c4b419646b1c1008 (MD5) IEEE_ECE.bst: 61899 bytes, checksum: 7509566d10f8075f0fad3df817415508 (MD5) PhD_Thesis.tex: 7207 bytes, checksum: 732628870059aaac31bee0c4612d62d8 (MD5) abs.tex: 2078 bytes, checksum: 3bca1fe8ed94c16a697b951d6ee6a6e7 (MD5) ack.tex: 2908 bytes, checksum: d097d5ca4df9c0fba65f1d6e5f4f3bf9 (MD5) appendix.tex: 31201 bytes, checksum: 8f50a57be3a4fbf6ea2cfe3a6e43258b (MD5) computational.tex: 18025 bytes, checksum: e48aa0fa41a5a5552f47efc34fbbc730 (MD5) concl.tex: 6445 bytes, checksum: 2be15460f92d72baddc636c2a0feb5cb (MD5) experiment.tex: 36112 bytes, checksum: fe2e968da19d0e3c9cc53340d111aa4c (MD5) images.zip: 140215374 bytes, checksum: 8d841fb475ac9f5957d0c90e125a8bd1 (MD5) intro.tex: 28542 bytes, checksum: 8d7400ef051f41e16b3532cbf7035cea (MD5) reactor_kinetics.tex: 31362 bytes, checksum: b0757e478127bfddbd1534216e17cc82 (MD5) results.tex: 30796 bytes, checksum: 7a453b786dae1767a71914304b3f15ed (MD5) thesisrefs.bib: 33541 bytes, checksum: 3c6ba685e4d0458948c1f6896612af42 (MD5) uiucecethesis09.cls: 22309 bytes, checksum: dbfcb6ce43781de390491449cbb14480 (MD5) uncertainty.tex: 18520 bytes, checksum: 0c15909247653c9f1bbde367fc960c77 (MD5) LICENSE.txt: 4212 bytes, checksum: 6df9dad181ad1892d1975835e25c7381 (MD5) PROQUEST_LICENSE.txt: 4558 bytes, checksum: 425f156bfaed61350e9aa6f1befc36a9 (MD5) Previous issue date: 2018-03-13"],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/2142/100908"],"dc:language":["en"],"dc:rights":["Copyright 2018 George McKenzie"],"dc:subject":["Rossi-alpha, neutron noise, critical experiment, subcritical reactivity"],"dc:title":["Limits on subcritical reactivity determination using rossi-alpha and related methods"],"dc:type":["text"],"thesis:degree_discipline":["Nuclear, Plasma, Radiolgc Engr"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Ph.D."],"thesis:institution_name":["University of Illinois at Urbana-Champaign"]},"updated_at":"2026-07-22T22:24:38Z"}