{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-1388"},"canonical_url":"https://search.dev.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-1388","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Advances In The Opto-mechanical Design And Alignment Of The Hehsi Imaging Spectrometer Based On A Sagnac Interferometer","abstract":"The High Efficiency HyperSpectral Imager (HEHSI) is a Fourier Transform hyperspectral imager based on a Sagnac interferometer. This thesis research concentrates on the design upgrade and calibration of HEHSI from a proof of concept instrument to a prototype field instrument. Stability is enhanced by removing degrees of freedom and alignment is enhanced by providing for in-situ adjustments. The use of off the shelf components allows for reduced development time and cost constraints. HEHSI is capable of multiple configurations to accommodate sensors and optics with specialized capabilities for multiple wavelength ranges and viewing conditions. With a spectral response of 400 to 1000 nanometers in the visible and very near IR as well as 900 to 1700nm in the Near IR. Creation and use of a real time feedback alignment utility allow quantifiable signal comparison and image alignment. Advances allow for HEHSI to remain aligned during data collection sessions and confirmation of alignment through quantitative measures.","abstract_html":"The High Efficiency HyperSpectral Imager (HEHSI) is a Fourier Transform hyperspectral imager based on a Sagnac interferometer. This thesis research concentrates on the design upgrade and calibration of HEHSI from a proof of concept instrument to a prototype field instrument. Stability is enhanced by removing degrees of freedom and alignment is enhanced by providing for in-situ adjustments. The use of off the shelf components allows for reduced development time and cost constraints. HEHSI is capable of multiple configurations to accommodate sensors and optics with specialized capabilities for multiple wavelength ranges and viewing conditions. With a spectral response of 400 to 1000 nanometers in the visible and very near IR as well as 900 to 1700nm in the Near IR. Creation and use of a real time feedback alignment utility allow quantifiable signal comparison and image alignment. Advances allow for HEHSI to remain aligned during data collection sessions and confirmation of alignment through quantitative measures.","abstract_has_math":false,"creators":["Schreiber, Michael Stuart"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Ham, Chan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005-01-01T08:00:00Z","date_published":"2005-01-01T08:00:00Z","updated_at":"2026-07-24T05:08:31Z","subjects":["Sagnac interferometer hyperspectral imager optomechanical","Engineering","Mechanical Engineering"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000553"],"render_values":[{"text":"CFE0000553","href":null,"code":true}]}]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/389","outbound_label":"Repository record","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ham, Chan"]},{"key":"dc:creator","label":"Author","values":["Schreiber, Michael Stuart"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Sagnac interferometer hyperspectral imager optomechanical","Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000553"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/389"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science in Mechanical Engineering (M.S.M.E.)","College of Engineering and Computer Science","Mechanical, Materials, and Aerospace Engineering","Mechanical Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["The High Efficiency HyperSpectral Imager (HEHSI) is a Fourier Transform hyperspectral imager based on a Sagnac interferometer. This thesis research concentrates on the design upgrade and calibration of HEHSI from a proof of concept instrument to a prototype field instrument. Stability is enhanced by removing degrees of freedom and alignment is enhanced by providing for in-situ adjustments. The use of off the shelf components allows for reduced development time and cost constraints. HEHSI is capable of multiple configurations to accommodate sensors and optics with specialized capabilities for multiple wavelength ranges and viewing conditions. With a spectral response of 400 to 1000 nanometers in the visible and very near IR as well as 900 to 1700nm in the Near IR. Creation and use of a real time feedback alignment utility allow quantifiable signal comparison and image alignment. Advances allow for HEHSI to remain aligned during data collection sessions and confirmation of alignment through quantitative measures."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Advances In The Opto-mechanical Design And Alignment Of The Hehsi Imaging Spectrometer Based On A Sagnac Interferometer"]}]}],"canonical_facts":{"dc:contributor":["Ham, Chan"],"dc:creator":["Schreiber, Michael Stuart"],"dc:description":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science in Mechanical Engineering (M.S.M.E.)","College of Engineering and Computer Science","Mechanical, Materials, and Aerospace Engineering","Mechanical Engineering"],"dc:description.abstract":["The High Efficiency HyperSpectral Imager (HEHSI) is a Fourier Transform hyperspectral imager based on a Sagnac interferometer. This thesis research concentrates on the design upgrade and calibration of HEHSI from a proof of concept instrument to a prototype field instrument. Stability is enhanced by removing degrees of freedom and alignment is enhanced by providing for in-situ adjustments. The use of off the shelf components allows for reduced development time and cost constraints. HEHSI is capable of multiple configurations to accommodate sensors and optics with specialized capabilities for multiple wavelength ranges and viewing conditions. With a spectral response of 400 to 1000 nanometers in the visible and very near IR as well as 900 to 1700nm in the Near IR. Creation and use of a real time feedback alignment utility allow quantifiable signal comparison and image alignment. Advances allow for HEHSI to remain aligned during data collection sessions and confirmation of alignment through quantitative measures."],"dc:format":["application/pdf"],"dc:identifier":["CFE0000553"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/389"],"dc:language":["English"],"dc:subject":["Sagnac interferometer hyperspectral imager optomechanical","Engineering","Mechanical Engineering"],"dc:title":["Advances In The Opto-mechanical Design And Alignment Of The Hehsi Imaging Spectrometer Based On A Sagnac Interferometer"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-07-24T05:08:31Z"}