{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-1185"},"canonical_url":"https://search.dev.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-1185","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Hydrogen Sulfide Flux Measurements And Dispersion Modeling From Constr","abstract":"Odor problems are a common complaint from residents living near landfills. Many compounds can cause malodorous conditions. However, hydrogen sulfide (h2s) has been identified as a principal odorous component from construction and demolition (c&d)debris landfills. Although several studies have reported the ambient concentrations of h2s near c&d landfills, few studies have quantified emission rates of h2s. The most widely used and proven technique for measuring gas emission rates from landfills is the flux chamber method. Typically the flux chamber is a cylindrical enclosure device with a spherical top which limits the gas emission area. Pure zero grade air is introduced into the chamber, allowed to mix with emitting gases captured from the landfill surface, and then transported to the exit port where concentrations can be measured. Flux measurements using the flux chamber were performed at five different c&d landfills from june to august, 2003. The flux rates of h2s measured in this research were three to six orders of magnitude lower than the flux rates of methane reported in the literature. In addition to the h2s flux measurements, dispersion modeling was conducted, using the epa dispersion model, industrial source complex short term (iscst3), in order to evaluate impacts on landfill workers and communities around the landfills. The modeling results were analyzed to estimate the potential ground level maximum h2s concentrations for 1-hr and 3-min periods and the frequency (occurrences per year) above the h2s odor detection threshold for each landfill. Odor complaints could be expected from four among five landfills selected for this study, based on 0.5-ppb odor detection threshold.","abstract_html":"Odor problems are a common complaint from residents living near landfills. Many compounds can cause malodorous conditions. However, hydrogen sulfide (h2s) has been identified as a principal odorous component from construction and demolition (c&amp;d)debris landfills. Although several studies have reported the ambient concentrations of h2s near c&amp;d landfills, few studies have quantified emission rates of h2s. The most widely used and proven technique for measuring gas emission rates from landfills is the flux chamber method. Typically the flux chamber is a cylindrical enclosure device with a spherical top which limits the gas emission area. Pure zero grade air is introduced into the chamber, allowed to mix with emitting gases captured from the landfill surface, and then transported to the exit port where concentrations can be measured. Flux measurements using the flux chamber were performed at five different c&amp;d landfills from june to august, 2003. The flux rates of h2s measured in this research were three to six orders of magnitude lower than the flux rates of methane reported in the literature. In addition to the h2s flux measurements, dispersion modeling was conducted, using the epa dispersion model, industrial source complex short term (iscst3), in order to evaluate impacts on landfill workers and communities around the landfills. The modeling results were analyzed to estimate the potential ground level maximum h2s concentrations for 1-hr and 3-min periods and the frequency (occurrences per year) above the h2s odor detection threshold for each landfill. Odor complaints could be expected from four among five landfills selected for this study, based on 0.5-ppb odor detection threshold.","abstract_has_math":false,"creators":["Eun, Sangho"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Reinhart, Debra"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-01-01T08:00:00Z","date_published":"2004-01-01T08:00:00Z","updated_at":"2026-07-24T05:08:16Z","subjects":["hydrogen sulfide","odor","C&D landfill","flux chamber","flux measurement","dispersion modeling","ISCST3","Engineering","Environmental Engineering"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000169"],"render_values":[{"text":"CFE0000169","href":null,"code":true}]}]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/186","outbound_label":"Repository record","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Reinhart, Debra"]},{"key":"dc:creator","label":"Author","values":["Eun, Sangho"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["hydrogen sulfide","odor","C&D landfill","flux chamber","flux measurement","dispersion modeling","ISCST3","Engineering","Environmental Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000169"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/186"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science (M.S.)","College of Engineering and Computer Science","Civil and Environmental Engineering","Environmental Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["Odor problems are a common complaint from residents living near landfills. Many compounds can cause malodorous conditions. However, hydrogen sulfide (h2s) has been identified as a principal odorous component from construction and demolition (c&d)debris landfills. Although several studies have reported the ambient concentrations of h2s near c&d landfills, few studies have quantified emission rates of h2s. The most widely used and proven technique for measuring gas emission rates from landfills is the flux chamber method. Typically the flux chamber is a cylindrical enclosure device with a spherical top which limits the gas emission area. Pure zero grade air is introduced into the chamber, allowed to mix with emitting gases captured from the landfill surface, and then transported to the exit port where concentrations can be measured. Flux measurements using the flux chamber were performed at five different c&d landfills from june to august, 2003. The flux rates of h2s measured in this research were three to six orders of magnitude lower than the flux rates of methane reported in the literature. In addition to the h2s flux measurements, dispersion modeling was conducted, using the epa dispersion model, industrial source complex short term (iscst3), in order to evaluate impacts on landfill workers and communities around the landfills. The modeling results were analyzed to estimate the potential ground level maximum h2s concentrations for 1-hr and 3-min periods and the frequency (occurrences per year) above the h2s odor detection threshold for each landfill. Odor complaints could be expected from four among five landfills selected for this study, based on 0.5-ppb odor detection threshold."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Hydrogen Sulfide Flux Measurements And Dispersion Modeling From Constr"]}]}],"canonical_facts":{"dc:contributor":["Reinhart, Debra"],"dc:creator":["Eun, Sangho"],"dc:description":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science (M.S.)","College of Engineering and Computer Science","Civil and Environmental Engineering","Environmental Engineering"],"dc:description.abstract":["Odor problems are a common complaint from residents living near landfills. Many compounds can cause malodorous conditions. However, hydrogen sulfide (h2s) has been identified as a principal odorous component from construction and demolition (c&d)debris landfills. Although several studies have reported the ambient concentrations of h2s near c&d landfills, few studies have quantified emission rates of h2s. The most widely used and proven technique for measuring gas emission rates from landfills is the flux chamber method. Typically the flux chamber is a cylindrical enclosure device with a spherical top which limits the gas emission area. Pure zero grade air is introduced into the chamber, allowed to mix with emitting gases captured from the landfill surface, and then transported to the exit port where concentrations can be measured. Flux measurements using the flux chamber were performed at five different c&d landfills from june to august, 2003. The flux rates of h2s measured in this research were three to six orders of magnitude lower than the flux rates of methane reported in the literature. In addition to the h2s flux measurements, dispersion modeling was conducted, using the epa dispersion model, industrial source complex short term (iscst3), in order to evaluate impacts on landfill workers and communities around the landfills. The modeling results were analyzed to estimate the potential ground level maximum h2s concentrations for 1-hr and 3-min periods and the frequency (occurrences per year) above the h2s odor detection threshold for each landfill. Odor complaints could be expected from four among five landfills selected for this study, based on 0.5-ppb odor detection threshold."],"dc:format":["application/pdf"],"dc:identifier":["CFE0000169"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/186"],"dc:language":["English"],"dc:subject":["hydrogen sulfide","odor","C&D landfill","flux chamber","flux measurement","dispersion modeling","ISCST3","Engineering","Environmental Engineering"],"dc:title":["Hydrogen Sulfide Flux Measurements And Dispersion Modeling From Constr"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-07-24T05:08:16Z"}