{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-1151"},"canonical_url":"https://search.dev.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-1151","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Basic Study Of Micromachined Dep (dielectrophoretic) Manipulator","abstract":"The capability of manipulating microparticle in small volumes is fundamental to many biological and medical applications, including separation and detection of cells. The development of microtools for effective sample handling and separation in such volumes is still a challenge. DEP (dielectrophoresis) is one of the most widely used methods in handling the microparticles. In this thesis we show that forces generated by nonuniform electric field (DEP) can be used for trapping and separating the microparticles (latex beads). This work further explores the DEP force based on different electrode geometries and medium conductivity. A micromanipulator for latex bead separation was designed, fabricated and characterized. For the development of DEP manipulator, the fabrication and packaging of microfluidic structure with the microelectrode is crucial for reliable analysis. A combination of SU-8 photoresist and polydimethylsiloxane polymer was used for this purpose. Besides, the DEP manipulator, preliminary study on a Coulter counter was conducted. The Coulter counter works on the principle of resistive pulse sensing. This counter is used for counting the beads as they pass through the microfluidic channel. Its possible integration with the manipulator was also explored.","abstract_html":"The capability of manipulating microparticle in small volumes is fundamental to many biological and medical applications, including separation and detection of cells. The development of microtools for effective sample handling and separation in such volumes is still a challenge. DEP (dielectrophoresis) is one of the most widely used methods in handling the microparticles. In this thesis we show that forces generated by nonuniform electric field (DEP) can be used for trapping and separating the microparticles (latex beads). This work further explores the DEP force based on different electrode geometries and medium conductivity. A micromanipulator for latex bead separation was designed, fabricated and characterized. For the development of DEP manipulator, the fabrication and packaging of microfluidic structure with the microelectrode is crucial for reliable analysis. A combination of SU-8 photoresist and polydimethylsiloxane polymer was used for this purpose. Besides, the DEP manipulator, preliminary study on a Coulter counter was conducted. The Coulter counter works on the principle of resistive pulse sensing. This counter is used for counting the beads as they pass through the microfluidic channel. Its possible integration with the manipulator was also explored.","abstract_has_math":false,"creators":["Sundaram, Vivek"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Sundaram, Kalpathy B."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-01-01T08:00:00Z","date_published":"2004-01-01T08:00:00Z","updated_at":"2026-07-24T05:08:16Z","subjects":["Coulter counter","Dielectrophoresis","Interdigitated electrodes","PDMS","SU 8","Electrical and Computer Engineering","Engineering","Dissertations, Academic -- Engineering and Computer Science; Engineering and Computer Science -- Dissertations, Academic"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000121"],"render_values":[{"text":"CFE0000121","href":null,"code":true}]}]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/152","outbound_label":"Repository record","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sundaram, Kalpathy B."]},{"key":"dc:creator","label":"Author","values":["Sundaram, Vivek"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Coulter counter","Dielectrophoresis","Interdigitated electrodes","PDMS","SU 8","Electrical and Computer Engineering","Engineering","Dissertations, Academic -- Engineering and Computer Science; Engineering and Computer Science -- Dissertations, Academic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000121"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/152"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science (M.S.)","College of Engineering and Computer Science","Electrical and Computer Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["The capability of manipulating microparticle in small volumes is fundamental to many biological and medical applications, including separation and detection of cells. The development of microtools for effective sample handling and separation in such volumes is still a challenge. DEP (dielectrophoresis) is one of the most widely used methods in handling the microparticles. In this thesis we show that forces generated by nonuniform electric field (DEP) can be used for trapping and separating the microparticles (latex beads). This work further explores the DEP force based on different electrode geometries and medium conductivity. A micromanipulator for latex bead separation was designed, fabricated and characterized. For the development of DEP manipulator, the fabrication and packaging of microfluidic structure with the microelectrode is crucial for reliable analysis. A combination of SU-8 photoresist and polydimethylsiloxane polymer was used for this purpose. Besides, the DEP manipulator, preliminary study on a Coulter counter was conducted. The Coulter counter works on the principle of resistive pulse sensing. This counter is used for counting the beads as they pass through the microfluidic channel. Its possible integration with the manipulator was also explored."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Basic Study Of Micromachined Dep (dielectrophoretic) Manipulator"]}]}],"canonical_facts":{"dc:contributor":["Sundaram, Kalpathy B."],"dc:creator":["Sundaram, Vivek"],"dc:description":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science (M.S.)","College of Engineering and Computer Science","Electrical and Computer Engineering"],"dc:description.abstract":["The capability of manipulating microparticle in small volumes is fundamental to many biological and medical applications, including separation and detection of cells. The development of microtools for effective sample handling and separation in such volumes is still a challenge. DEP (dielectrophoresis) is one of the most widely used methods in handling the microparticles. In this thesis we show that forces generated by nonuniform electric field (DEP) can be used for trapping and separating the microparticles (latex beads). This work further explores the DEP force based on different electrode geometries and medium conductivity. A micromanipulator for latex bead separation was designed, fabricated and characterized. For the development of DEP manipulator, the fabrication and packaging of microfluidic structure with the microelectrode is crucial for reliable analysis. A combination of SU-8 photoresist and polydimethylsiloxane polymer was used for this purpose. Besides, the DEP manipulator, preliminary study on a Coulter counter was conducted. The Coulter counter works on the principle of resistive pulse sensing. This counter is used for counting the beads as they pass through the microfluidic channel. Its possible integration with the manipulator was also explored."],"dc:format":["application/pdf"],"dc:identifier":["CFE0000121"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/152"],"dc:language":["English"],"dc:subject":["Coulter counter","Dielectrophoresis","Interdigitated electrodes","PDMS","SU 8","Electrical and Computer Engineering","Engineering","Dissertations, Academic -- Engineering and Computer Science; Engineering and Computer Science -- Dissertations, Academic"],"dc:title":["Basic Study Of Micromachined Dep (dielectrophoretic) Manipulator"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-07-24T05:08:16Z"}