{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-1127"},"canonical_url":"https://search.dev.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-1127","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Finite Element Analysis Of A Test Specimen For Strength Of A Co-polymer Layer At A Bone-implant Interface","abstract":"The aim of this work is to evaluate the mechanical strength of a co-polymer of 2-hydroxyethylmethacrylate (HEMA) and methylmethacrylate (MMA), so that it can be applied as an interfacial layer between bone cement and steel implants to improve their performance and life. Finite element (FE) analysis techniques are used to assess the behavior of the interface layer under static and dynamic loading conditions. The material property of the co-polymer is a function of its composition and water saturation. The factors affecting the strength of the bone-implant interface are many. Implant interfacial fracture can lead to decreased stability. Fatigue life is a very important process in failure. The results obtained from static and dynamic analyses show that increasing the percentage of HEMA improves the strength of the interface by reducing the stiffness of the implant, absorbing more energy and by reducing the interfacial stress peaks and making the stress distribution more nearly uniform.","abstract_html":"The aim of this work is to evaluate the mechanical strength of a co-polymer of 2-hydroxyethylmethacrylate (HEMA) and methylmethacrylate (MMA), so that it can be applied as an interfacial layer between bone cement and steel implants to improve their performance and life. Finite element (FE) analysis techniques are used to assess the behavior of the interface layer under static and dynamic loading conditions. The material property of the co-polymer is a function of its composition and water saturation. The factors affecting the strength of the bone-implant interface are many. Implant interfacial fracture can lead to decreased stability. Fatigue life is a very important process in failure. The results obtained from static and dynamic analyses show that increasing the percentage of HEMA improves the strength of the interface by reducing the stiffness of the implant, absorbing more energy and by reducing the interfacial stress peaks and making the stress distribution more nearly uniform.","abstract_has_math":false,"creators":["Chhabra, Nitin"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Nicholson, David"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2004,"date_issued":"2004-01-01T08:00:00Z","date_published":"2004-01-01T08:00:00Z","updated_at":"2026-07-24T05:08:16Z","subjects":["FEA","LSDYNA","PMMA","Patran","Stress","Engineering","Dissertations, Academic -- Engineering and Computer Science; Engineering and Computer Science -- Dissertations, Academic"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000076"],"render_values":[{"text":"CFE0000076","href":null,"code":true}]}]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/128","outbound_label":"Repository record","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Nicholson, David"]},{"key":"dc:creator","label":"Author","values":["Chhabra, Nitin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FEA","LSDYNA","PMMA","Patran","Stress","Engineering","Dissertations, Academic -- Engineering and Computer Science; Engineering and Computer Science -- Dissertations, Academic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0000076"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/128"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science (M.S.)","College of Engineering and Computer Science","Mechanical, Materials, and Aerospace Engineering","Mechanical, Materials and Aerospace Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["The aim of this work is to evaluate the mechanical strength of a co-polymer of 2-hydroxyethylmethacrylate (HEMA) and methylmethacrylate (MMA), so that it can be applied as an interfacial layer between bone cement and steel implants to improve their performance and life. Finite element (FE) analysis techniques are used to assess the behavior of the interface layer under static and dynamic loading conditions. The material property of the co-polymer is a function of its composition and water saturation. The factors affecting the strength of the bone-implant interface are many. Implant interfacial fracture can lead to decreased stability. Fatigue life is a very important process in failure. The results obtained from static and dynamic analyses show that increasing the percentage of HEMA improves the strength of the interface by reducing the stiffness of the implant, absorbing more energy and by reducing the interfacial stress peaks and making the stress distribution more nearly uniform."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Finite Element Analysis Of A Test Specimen For Strength Of A Co-polymer Layer At A Bone-implant Interface"]}]}],"canonical_facts":{"dc:contributor":["Nicholson, David"],"dc:creator":["Chhabra, Nitin"],"dc:description":["<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","Master of Science (M.S.)","College of Engineering and Computer Science","Mechanical, Materials, and Aerospace Engineering","Mechanical, Materials and Aerospace Engineering"],"dc:description.abstract":["The aim of this work is to evaluate the mechanical strength of a co-polymer of 2-hydroxyethylmethacrylate (HEMA) and methylmethacrylate (MMA), so that it can be applied as an interfacial layer between bone cement and steel implants to improve their performance and life. Finite element (FE) analysis techniques are used to assess the behavior of the interface layer under static and dynamic loading conditions. The material property of the co-polymer is a function of its composition and water saturation. The factors affecting the strength of the bone-implant interface are many. Implant interfacial fracture can lead to decreased stability. Fatigue life is a very important process in failure. The results obtained from static and dynamic analyses show that increasing the percentage of HEMA improves the strength of the interface by reducing the stiffness of the implant, absorbing more energy and by reducing the interfacial stress peaks and making the stress distribution more nearly uniform."],"dc:format":["application/pdf"],"dc:identifier":["CFE0000076"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/128"],"dc:language":["English"],"dc:subject":["FEA","LSDYNA","PMMA","Patran","Stress","Engineering","Dissertations, Academic -- Engineering and Computer Science; Engineering and Computer Science -- Dissertations, Academic"],"dc:title":["Finite Element Analysis Of A Test Specimen For Strength Of A Co-polymer Layer At A Bone-implant Interface"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-07-24T05:08:16Z"}