Retrofitting beam-to-column joints for improved seismic performance microform

Abstract

dc:description

Before the 1970's, most codes for the design of reinforced concrete structures did not include provisions for ductility during seismic events was not prevalent in most codes. The guidelines that did exist were minimal, and often left a fair amount of room for interpretation by the design engineer. Hence, many of the reinforced concrete structures designed during that time are suspect under today's more stringent design guidelines. Moreover, even the present designs are often deficient and vary from building to building and from jurisdiction to jurisdiction. This report is a presentation of the findings of an experimental study to evaluate a method of retrofit which addresses a particular weakness that is often found in reinforced concrete structures, namely the lack of sufficient reinforcement in and around beam-to-column joints. Many of these structures lack the required confining reinforcement within the joints and in adjoining beams and columns. The result is a reinforced concrete framethat is weak in the joint area and lacks sufficient ductility during a seismic event. The proposed retrofit method consists of encasing the reinforced concrete joint with a grouted steel jacket that provides confinement to the joint area, and imparts ductility to the frame. In this study, two styles of retrofit jacket were tested: a circular steel tube and a rectangular casing. It was found that circular steel jackets have the advantage of providing direct concrete confinement and, as well, of furnishing a ductile force transfer mechanism through the jacket itself, but are also more difficult and expensive to fabricate than rectangular jackets. Although rectangular jackets do not provide the same degree of concrete core confinement as circular jackets, the amount available seems sufficient to prevent damage in the joint area. The load transfer mechanism of the rectangular jackets was found to be adequate in withstanding the loads and deflections typical for seismic events. In this thesis, the two jacket styles are evaluated for strength, stiffness and ductility, and their relative merits are discussed.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science - MASc
Level thesis:degree_level
master's
Discipline thesis:degree_discipline
Civil Engineering
Grantor dc:publisher
University of British Columbia
Year dc:date
1992

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hoffschild, Thomas E.

Rights

dc:rights
Statement dc:rights
  • For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2429/2461
OAI identifier oai:identifier
oai:circle.library.ubc.ca:2429/2461

Chain of custody

source
Harvested from
University of British Columbia
Base URL
circle.library.ubc.ca/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Hoffschild, Thomas E.. Retrofitting beam-to-column joints for improved seismic performance microform. master's thesis, University of British Columbia, 1992. http://hdl.handle.net/2429/2461