{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/2381"},"canonical_url":"https://search.dev.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/2381","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Transient analysis of six-phase synchronous machines","abstract":"Six-phase synchronous machines have been used in the past for high power generation, and presently are being used in high power electric drives and in ac and/or dc power supplies. This thesis presents a mathematical model for investigating the transient performance of a six-phase synchronous machine, and develops a model for the simulation of such machines with the EMTP. The effect of the mutual leakage coupling between the two sets of three-phase stator windings are included in the development of a d-q equivalent circuit. The six-phase machine is constructed from a three-phase machine by splitting the stator windings into two equal three-phase sets. The six-phase machine reactances and resistances are derived by relating their values to the known three-phase machine values. The transient performance of the machine is tested by solving the machine equations for a case of a six-phase short-circuit at the terminals of the machine. The EMTP model presented is based on representing the six-phase machine as two three-phase machines in parallel. The EMTP model verification is achieved by comparing the EMTP results against an independent computer program, for the case of a six-phase short-circuit test at the terminals of the machine.","abstract_html":"Six-phase synchronous machines have been used in the past for high power generation, and presently are being used in high power electric drives and in ac and/or dc power supplies. This thesis presents a mathematical model for investigating the transient performance of a six-phase synchronous machine, and develops a model for the simulation of such machines with the EMTP. The effect of the mutual leakage coupling between the two sets of three-phase stator windings are included in the development of a d-q equivalent circuit. The six-phase machine is constructed from a three-phase machine by splitting the stator windings into two equal three-phase sets. The six-phase machine reactances and resistances are derived by relating their values to the known three-phase machine values. The transient performance of the machine is tested by solving the machine equations for a case of a six-phase short-circuit at the terminals of the machine. The EMTP model presented is based on representing the six-phase machine as two three-phase machines in parallel. The EMTP model verification is achieved by comparing the EMTP results against an independent computer program, for the case of a six-phase short-circuit test at the terminals of the machine.","abstract_has_math":false,"creators":["Mozaffari, Said"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1993,"date_issued":"1993","date_published":"1993","updated_at":"2026-07-24T05:07:17Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/2381","outbound_label":"Handle","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mozaffari, Said"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1993"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/2381","http://circle.library.ubc.ca/bitstream/2429/2381/3/ubc_1993_spring_mozaffari_said.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Six-phase synchronous machines have been used in the past for high power generation, and presently are being used in high power electric drives and in ac and/or dc power supplies. This thesis presents a mathematical model for investigating the transient performance of a six-phase synchronous machine, and develops a model for the simulation of such machines with the EMTP. The effect of the mutual leakage coupling between the two sets of three-phase stator windings are included in the development of a d-q equivalent circuit. The six-phase machine is constructed from a three-phase machine by splitting the stator windings into two equal three-phase sets. The six-phase machine reactances and resistances are derived by relating their values to the known three-phase machine values. The transient performance of the machine is tested by solving the machine equations for a case of a six-phase short-circuit at the terminals of the machine. The EMTP model presented is based on representing the six-phase machine as two three-phase machines in parallel. The EMTP model verification is achieved by comparing the EMTP results against an independent computer program, for the case of a six-phase short-circuit test at the terminals of the machine."]},{"key":"dc:format","label":"Dc Format","values":["2940518","application/pdf"]},{"key":"dc:title","label":"Title","values":["Transient analysis of six-phase synchronous machines"]}]}],"canonical_facts":{"dc:creator":["Mozaffari, Said"],"dc:date":["1993"],"dc:description":["Six-phase synchronous machines have been used in the past for high power generation, and presently are being used in high power electric drives and in ac and/or dc power supplies. This thesis presents a mathematical model for investigating the transient performance of a six-phase synchronous machine, and develops a model for the simulation of such machines with the EMTP. The effect of the mutual leakage coupling between the two sets of three-phase stator windings are included in the development of a d-q equivalent circuit. The six-phase machine is constructed from a three-phase machine by splitting the stator windings into two equal three-phase sets. The six-phase machine reactances and resistances are derived by relating their values to the known three-phase machine values. The transient performance of the machine is tested by solving the machine equations for a case of a six-phase short-circuit at the terminals of the machine. The EMTP model presented is based on representing the six-phase machine as two three-phase machines in parallel. The EMTP model verification is achieved by comparing the EMTP results against an independent computer program, for the case of a six-phase short-circuit test at the terminals of the machine."],"dc:format":["2940518","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/2381","http://circle.library.ubc.ca/bitstream/2429/2381/3/ubc_1993_spring_mozaffari_said.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["Transient analysis of six-phase synchronous machines"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-07-24T05:07:17Z"}