{"id":{"repo_id":"uab","oai_identifier":"oai:digitalcommons.library.uab.edu:etd-collection-8117"},"canonical_url":"https://search.dev.ndltd.org/etd/uab/oai:digitalcommons.library.uab.edu:etd-collection-8117","repository":{"repo_id":"uab","name":"University of Alabama Birmingham","base_url":"https://digitalcommons.library.uab.edu/do/oai/"},"display":{"title":"The Effect of Ion Implantation on the Corrosive-Wear Resistance of Ti-6A1-4V.","abstract":"The human body will react to the introduction of any foreign material. The extent of this reaction depends not only on thematerial itself but on its size, shape and reaction products. Many surgical implant devices are subjected to wear and fretting processes which generate wear debris and corrosion products. Large volumes of corrosion products or wear debris can elicit a tissue response and may have a systemic effect in the body after a long period of exposure. These problems are of vital concern, especially with respect to prosthetic total joint replacements, since these implants should remain in situ for the life of the patient. Thus, attempts should be made to find a material which produces minimal corrosion products and wear debris. Ion implantation may be a means by which the corrosive wear resistance of surgical implant materials may be improved.","abstract_html":"The human body will react to the introduction of any foreign material. The extent of this reaction depends not only on thematerial itself but on its size, shape and reaction products. Many surgical implant devices are subjected to wear and fretting processes which generate wear debris and corrosion products. Large volumes of corrosion products or wear debris can elicit a tissue response and may have a systemic effect in the body after a long period of exposure. These problems are of vital concern, especially with respect to prosthetic total joint replacements, since these implants should remain in situ for the life of the patient. Thus, attempts should be made to find a material which produces minimal corrosion products and wear debris. Ion implantation may be a means by which the corrosive wear resistance of surgical implant materials may be improved.","abstract_has_math":false,"creators":["Bacon, Rhonda Kay"],"institution":null,"degree_name":null,"degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1983,"date_issued":"1983-01-01T08:00:00Z","date_published":"1983-01-01T08:00:00Z","updated_at":"2026-07-24T05:06:15Z","subjects":["Joint replacements","Ion implantation","Corrosive-wear resistance","Minimal corrosion"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.library.uab.edu/etd-collection/7125","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bacon, Rhonda Kay"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Joint replacements","Ion implantation","Corrosive-wear resistance","Minimal corrosion"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.library.uab.edu/etd-collection/7125"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The human body will react to the introduction of any foreign material. The extent of this reaction depends not only on thematerial itself but on its size, shape and reaction products. Many surgical implant devices are subjected to wear and fretting processes which generate wear debris and corrosion products. Large volumes of corrosion products or wear debris can elicit a tissue response and may have a systemic effect in the body after a long period of exposure. These problems are of vital concern, especially with respect to prosthetic total joint replacements, since these implants should remain in situ for the life of the patient. Thus, attempts should be made to find a material which produces minimal corrosion products and wear debris. Ion implantation may be a means by which the corrosive wear resistance of surgical implant materials may be improved."]},{"key":"dc:title","label":"Title","values":["The Effect of Ion Implantation on the Corrosive-Wear Resistance of Ti-6A1-4V."]}]}],"canonical_facts":{"dc:creator":["Bacon, Rhonda Kay"],"dc:description.abstract":["The human body will react to the introduction of any foreign material. The extent of this reaction depends not only on thematerial itself but on its size, shape and reaction products. Many surgical implant devices are subjected to wear and fretting processes which generate wear debris and corrosion products. Large volumes of corrosion products or wear debris can elicit a tissue response and may have a systemic effect in the body after a long period of exposure. These problems are of vital concern, especially with respect to prosthetic total joint replacements, since these implants should remain in situ for the life of the patient. Thus, attempts should be made to find a material which produces minimal corrosion products and wear debris. Ion implantation may be a means by which the corrosive wear resistance of surgical implant materials may be improved."],"dc:identifier":["https://digitalcommons.library.uab.edu/etd-collection/7125"],"dc:subject":["Joint replacements","Ion implantation","Corrosive-wear resistance","Minimal corrosion"],"dc:title":["The Effect of Ion Implantation on the Corrosive-Wear Resistance of Ti-6A1-4V."],"thesis:degree_level":["Thesis"]},"updated_at":"2026-07-24T05:06:15Z"}