Back to results

University of the Pacific

Rapid identification, confirmation, and quantitation using an open-air ion source coupled to a time-of-flight mass spectrometer

Abstract

dc:description.abstract

<p>The ability to identify and confirm a compound using mass spectrometry usually involves time consuming sample preparation and method development. The open-air ion source DART (Direct Analysis in Real Time) can ionize compounds in the gas, solid, or liquid phase without chromatography or sample preparation due to the interactions of helium metastable atoms with gas molecules commonly found in air. The coupling of the DART to a time-of-flight (TOF) mass spectrometer allows the rapid determination of an analyte's elemental composition based on accurate mass measurement and isotope peak intensities. Mass spectrometric fragmentation data can aid in the structural identification of an analyte as compounds produce characteristic fragment-ions based on their structure. The TOP's ability to produce fragmentation spectra was compared to the more traditional tandem mass spectral method (MS/MS) considering the TOF lacks the ability to select pre-cursor ions. The TOF produced in-source CAD (collisionally activated dissociation) spectra comparable to MS/MS spectra for three well known pharmaceuticals acetaminophen, phenylbutazone and clenbuterol. Further structural confirmation was explored through a determination of the number of active hydrogen atoms in an analyte molecule achieved by hydrogen/deuterium (H/D) exchange by treatment with deuterium oxide (D<sub>2</sub>0) in the DART sample gap. Mass spectra acquired in the presence of D<sub>2</sub>0 of analytes containing active hydrogen atoms associated with hydroxyl, amino and carboxylic acid groups showed that H/D exchange was predictable and reproducible.</p> <p>Using accurate mass measurement and isotope peak intensities, the elemental composition of an unknown captured on filter paper was identified as dipropylene glycol (DPG) analyzed directly from the surface of the filter paper. Data from in-source CAD and H/D exchange of both the unknown and authentic standards confirmed that the unknown was DPG. The cross-correlation of accurate mass measurement and isotope peak intensities, in-source CAD and HID exchange data provided an unambiguous identification of the contaminant melamine in dog food without the need for any sample preparation.</p> <p>Once analytes are identified and confirmed, quantitation of the analyte is desirable. The calibration curves here are constructed using the net extracted ion-current associated with the analyte relative to the internal standard. In cough syrup, a complicated matrix, the linearity, R<sup>2</sup>, is shown to be 0.992.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.S.)
Level thesis:degree_level
Thesis - Pacific Access Restricted
Discipline thesis:degree_discipline
Chemistry
Year dc:date.available
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vail, Teresa M.
Contributors dc:contributor
  • Patrick R. Jones

Subjects

dc:subject × 5

Rights

dc:rights

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarlycommons.pacific.edu/uop_etds/666
OAI identifier oai:identifier
oai:scholarlycommons.pacific.edu:uop_etds-1665

Chain of custody

source
Harvested from
University of the Pacific
Base URL
scholarlycommons.pacific.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Vail, Teresa M.. Rapid identification, confirmation, and quantitation using an open-air ion source coupled to a time-of-flight mass spectrometer. Thesis - Pacific Access Restricted thesis, 2007. https://scholarlycommons.pacific.edu/uop_etds/666