Back to results

Texas Tech University

Magnetic flux compression for high voltage pulse applications

Abstract

dc:description.abstract

Helical Magnetic Flux Compression Generators (MFCG) are the most promising energy sources with respect to their current amplification and compactness. However, their intrinsic flux loss limits severely their performance and it is not yet well understood. All flux losses have a differing degree of impact, depending on the generator's volume, current and energy amplification, size of the driven load, and angular frequency of armature-helix contact point. Although several computer models have been developed, none of them truly quantify the ohmic and intrinsic flux losses. This dissertation describes a novel method that provides a separate calculation of intrinsic flux losses (flux that is left behind in the conductors and lost for compression) and ohmic losses. It also provides a second method that uses simple flux quantification, making a mathematical connection between the intrinsic flux losses, quantified by the first method, and the intrinsic flux losses observed in the generators. This second method can also be used with the first method to a priori estimate the MFCG performance. Simple MFCG with a single helix produce high output energy only into low inductance loads, thus producing several 100 kA of current at a voltage level of less than l0kV. Many pulsed power devices require less current but a considerably higher voltage level. For effectively driving a high inductance load of several µH, a multistage MFCG design has also been successfully tested with a total length of 250 mm, a helix inner diameter of 51 mm, achieving an energy gain of ~13 into a 3 µH load. Further power conditioning utilizing an exploding wire fuse enables driving an electron beam device. Typical load parameters of electron beam devices are several 100 kV operating voltage with an impedance of a few tens of Ohms. Utilizing a multi-stage FCG as primary source for inductive energy storage with opening switch enables the production of voltages in excess of 100's kV. We built an exploding wire fuse with a length of 140mm and 100mm in diameter (including the storage inductor), conditioned to the MFCG described above. We achieved a voltage of ~ 42kV directly across the 3µH inductor, and more than 130kV with the fuse opening switch operating into a ~12-15 Ù load.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Electrical Engineering
Grantor dc:publisher
Texas Tech University
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hernandez Llambes, Juan Carlos

Subjects

dc:subject × 7

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/2346/11961
OAI identifier oai:identifier
oai:ttu-ir.tdl.org:2346/11961

Chain of custody

source
Harvested from
Texas Technology University
Base URL
ttu-ir.tdl.org/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Hernandez Llambes, Juan Carlos. Magnetic flux compression for high voltage pulse applications. Doctoral thesis, Texas Tech University, 2004. http://hdl.handle.net/2346/11961