{"id":{"repo_id":"texas","oai_identifier":"oai:repositories.lib.utexas.edu:2152/ETD-UT-2012-05-5321"},"canonical_url":"https://search.dev.ndltd.org/etd/texas/oai:repositories.lib.utexas.edu:2152/ETD-UT-2012-05-5321","repository":{"repo_id":"texas","name":"University of Texas","base_url":"https://repositories.lib.utexas.edu/server/oai/request"},"display":{"title":"Design, fabrication, and testing of a MEMS z-axis Directional Piezoelectric Microphone","abstract":"Directional microphones, which suppress noise coming from unwanted directions while preserving sound signals arriving from a desired direction, are essential to hearing aid technology. The device presented in this paper abandons the principles of standard pressure sensor microphones, dual port microphones, and multi-chip array systems and instead employs a new method of operation. The proposed device uses a lightweight silicon micromachined structure that becomes “entrained” in the oscillatory motion of air vibrations, and thus maintains the vector component of the air velocity. The mechanical structures are made as compliant as possible so that the motion of the diaphragm directly replicates the motion of the sound wave as it travels through air. The microphone discussed in this paper achieves the bi-directionality seen in a ribbon microphone but is built using standard semiconductor fabrication techniques and utilizes piezoelectric readout of a circular diaphragm suspended on compliant silicon springs. Finite element analysis and lumped element modeling have been performed to aid in structural design and device verification. The proposed microphone was successfully fabricated in a cleanroom facility at The University of Texas at Austin. Testing procedures verified that the resonant frequency of the microphone, as expected, was much lower than in traditional microphones. This report discusses the theory, modeling, fabrication and testing of the microphone.","abstract_html":"Directional microphones, which suppress noise coming from unwanted directions while preserving sound signals arriving from a desired direction, are essential to hearing aid technology. The device presented in this paper abandons the principles of standard pressure sensor microphones, dual port microphones, and multi-chip array systems and instead employs a new method of operation. The proposed device uses a lightweight silicon micromachined structure that becomes “entrained” in the oscillatory motion of air vibrations, and thus maintains the vector component of the air velocity. The mechanical structures are made as compliant as possible so that the motion of the diaphragm directly replicates the motion of the sound wave as it travels through air. The microphone discussed in this paper achieves the bi-directionality seen in a ribbon microphone but is built using standard semiconductor fabrication techniques and utilizes piezoelectric readout of a circular diaphragm suspended on compliant silicon springs. Finite element analysis and lumped element modeling have been performed to aid in structural design and device verification. The proposed microphone was successfully fabricated in a cleanroom facility at The University of Texas at Austin. Testing procedures verified that the resonant frequency of the microphone, as expected, was much lower than in traditional microphones. This report discusses the theory, modeling, fabrication and testing of the microphone.","abstract_has_math":false,"creators":["Kirk, Karen Denise"],"institution":"University of Texas at Austin","degree_name":"Master of Science in Engineering","degree_level":"Masters","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Hall, Neal A."],"committee_chairs":[],"committee_members":["Neikirk, Dean P."],"year":2012,"date_issued":"2012-05","date_published":"2012-05","updated_at":"2026-07-24T05:01:16Z","subjects":["Micromachined","MEMS","Microphone","Piezoelectric","Sensors","Fabrication","Silicon"],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2152/ETD-UT-2012-05-5321","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hall, Neal A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Neikirk, Dean P."]},{"key":"dc:creator","label":"Author","values":["Kirk, Karen Denise"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-16T14:58:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-08-16T14:58:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-05"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Engineering"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Texas at Austin"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Micromachined","MEMS","Microphone","Piezoelectric","Sensors","Fabrication","Silicon"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/2152/ETD-UT-2012-05-5321"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["text"]},{"key":"dc:description.abstract","label":"Abstract","values":["Directional microphones, which suppress noise coming from unwanted directions while preserving sound signals arriving from a desired direction, are essential to hearing aid technology. The device presented in this paper abandons the principles of standard pressure sensor microphones, dual port microphones, and multi-chip array systems and instead employs a new method of operation. The proposed device uses a lightweight silicon micromachined structure that becomes “entrained” in the oscillatory motion of air vibrations, and thus maintains the vector component of the air velocity. The mechanical structures are made as compliant as possible so that the motion of the diaphragm directly replicates the motion of the sound wave as it travels through air. The microphone discussed in this paper achieves the bi-directionality seen in a ribbon microphone but is built using standard semiconductor fabrication techniques and utilizes piezoelectric readout of a circular diaphragm suspended on compliant silicon springs. Finite element analysis and lumped element modeling have been performed to aid in structural design and device verification. The proposed microphone was successfully fabricated in a cleanroom facility at The University of Texas at Austin. Testing procedures verified that the resonant frequency of the microphone, as expected, was much lower than in traditional microphones. This report discusses the theory, modeling, fabrication and testing of the microphone."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design, fabrication, and testing of a MEMS z-axis Directional Piezoelectric Microphone"]}]}],"canonical_facts":{"dc:contributor.advisor":["Hall, Neal A."],"dc:contributor.committeemember":["Neikirk, Dean P."],"dc:creator":["Kirk, Karen Denise"],"dc:date.accessioned":["2012-08-16T14:58:04Z"],"dc:date.available":["2012-08-16T14:58:04Z"],"dc:date.issued":["2012-05"],"dc:description":["text"],"dc:description.abstract":["Directional microphones, which suppress noise coming from unwanted directions while preserving sound signals arriving from a desired direction, are essential to hearing aid technology. The device presented in this paper abandons the principles of standard pressure sensor microphones, dual port microphones, and multi-chip array systems and instead employs a new method of operation. The proposed device uses a lightweight silicon micromachined structure that becomes “entrained” in the oscillatory motion of air vibrations, and thus maintains the vector component of the air velocity. The mechanical structures are made as compliant as possible so that the motion of the diaphragm directly replicates the motion of the sound wave as it travels through air. The microphone discussed in this paper achieves the bi-directionality seen in a ribbon microphone but is built using standard semiconductor fabrication techniques and utilizes piezoelectric readout of a circular diaphragm suspended on compliant silicon springs. Finite element analysis and lumped element modeling have been performed to aid in structural design and device verification. The proposed microphone was successfully fabricated in a cleanroom facility at The University of Texas at Austin. Testing procedures verified that the resonant frequency of the microphone, as expected, was much lower than in traditional microphones. This report discusses the theory, modeling, fabrication and testing of the microphone."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/2152/ETD-UT-2012-05-5321"],"dc:language.iso":["eng"],"dc:subject":["Micromachined","MEMS","Microphone","Piezoelectric","Sensors","Fabrication","Silicon"],"dc:title":["Design, fabrication, and testing of a MEMS z-axis Directional Piezoelectric Microphone"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Masters"],"thesis:degree_name":["Master of Science in Engineering"],"thesis:institution_name":["University of Texas at Austin"]},"updated_at":"2026-07-24T05:01:16Z"}