Abstract

dc:description.abstract

This project addresses characterization of the material properties of aortic tissue. Understanding of these properties is important for a variety of studies including tissue engineering, effects of aging and diseases, stents engineering, and traumatic aorta rupture. The goal of the presented research was to characterize the stress-strain relationship of aorta in dynamic oscillatory biaxial loading. A setup was developed that supplied pressure loading from the physiological to sub-failure levels (between 7 and 76 kPa) to porcine aorta at frequencies ranging from 0.50Hz to 5.00Hz. Samples tested were constrained at both ends while the deformation and the pressure were recorded. Volumetric strain versus pressure was used to characterize the structural behavior of the material which showed frequency dependency and hysteresis indicating viscoelastic response. An offset method was developed to account for drifting behavior exhibited by some of the samples. The structural behavior of aorta was modeled using a quasi-linear viscoelastic (QLV) creep theory. The QLV model included a logarithmic steady state elastic function v = 0.663 +/- 0.040 + 0.241 +/- 0.011 ln(P) for pressure in kPa, and a Prony series creep function ( J0 = 0.472 +/- 0.021, J2 = 0.109 +/- 0.060, J3 = 0.419 +/- 0.056). Modeling results were then used to determine the relationships between the circumferential and longitudinal stresses and strains of the material. The results exhibited that the stress in the transverse direction was about 1.5 times larger than in the axial direction. However, in the axial direction material was stiffer and the deformation was 30% less. The relaxation function of the material was determined by linearizing the non-linear component of the QLV model and applying to it the linear viscoelastic theory. Furthermore, literature comparison revealed that aorta's creep function, as well as its elastic modulus, is within the range of what has been reported in the literature. In conclusion, an experimental model was developed that can be used to predict the behavior of porcine aorta under physiological and sub-failure conditions at quasi-static and dynamic loading.

Degree

thesis:*
Grantor dc:publisher
Temple University. Libraries
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Romanov, Vasily Vladimirovich
Advisor dc:contributor.advisor
  • Darvish, Kurosh
Committee members dc:contributor.committeemember
  • Kiani, Mohammad F.
  • Hutapea, Parsaoran

Subjects

dc:subject × 9

Rights

dc:rights
Statement dc:rights
  • IN COPYRIGHT- This Rights Statement can be used for an Item that is in copyright. Using this statement implies that the organization making this Item available has determined that the Item is in copyright and either is the rights-holder, has obtained permission from the rights-holder(s) to make their Work(s) available, or makes the Item available under an exception or limitation to copyright (including Fair Use) that entitles it to make the Item available.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Other
864884943
OAI identifier oai:identifier
oai:scholarshare.temple.edu:20.500.12613/2259

Chain of custody

source
Harvested from
Temple University
Base URL
scholarshare.temple.edu/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
citation

Romanov, Vasily Vladimirovich. MATERIAL PROPERTIES OF AORTA FROM BIAXIAL OSCILLATORY TESTS. Temple University. Libraries, 2010. http://hdl.handle.net/20.500.12613/2259