Back to results

Temple University. Libraries

ACCURACY OF SURVEYED CROWN DESIGN DUPLICATION WITH CAD/CAM TECHNOLOGY COMPARED WITH CONVENTIONAL METHODS IN PARTIALLY EDENTULOUS KENNEDY CLASS III ARCH FORM

Abstract

dc:description.abstract

Fabrication of a surveyed crown under an existing RPD requires designing a crown pattern that duplicates the coronal anatomy of the existing tooth including all undercut and non-undercut areas and occlusal rest seats. The aim of this study was to evaluate the accuracy of surveyed crown design duplication with CAD/CAM technology compared with the conventional methods in partially edentulous Kennedy class III arch form in an in vitro study. A maxillary dentiform with Kennedy Class III partial edentulism was used (missing teeth #4,13,14). Tooth #3 was prepared, and a PFM surveyed crown was fabricated and cemented with the appropriate contours to receive an Akers-type clasp: distal rest, circumferential direct retainer and reciprocal arm. A cast chrome-cobalt RPD framework was fabricated using conventional methods. The existing PFM crown was replaced by the surveyed study crowns for comparison. 10 PFM crowns were fabricated using a conventional method and 10 Zirconia crowns were fabricated using CAD/CAM method. The vertical position of HOC and crown thicknesses were measured in six spots (MB, B, DB, MP, P , DP) on each crown. The results of the present study indicated that CAD/CAM technology provided superior accuracy of surveyed crown design duplication compared to the conventional method. In terms of HOC vertical position, CAD/CAM crowns were significantly more accurate than the conventional crowns on the buccal side of the crown. On average, the HOC on the conventional crowns was 0.83  0.37, 1.27  0.64, and 1.23  0.48 mm higher than the control crown on the MB, B, and DB sites, respectively. On the lingual side, there was no significant difference between the two methods. In terms of the crown thickness, both methods yielded relatively similar results. The largest difference in crown thickness between test and control crowns was found in the DB site of the conventional group where the crowns were significantly thinner than the control.

Degree

thesis:*
Grantor dc:publisher
Temple University. Libraries
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ghassemi, Ghazal Ghassemi
Advisor dc:contributor.advisor
  • DiPede, Louis
Committee members dc:contributor.committeemember
  • Whitaker, Eugene J.
  • Orrego, Santiago

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • IN COPYRIGHT- This Rights Statement can be used for an Item that is in copyright. Using this statement implies that the organization making this Item available has determined that the Item is in copyright and either is the rights-holder, has obtained permission from the rights-holder(s) to make their Work(s) available, or makes the Item available under an exception or limitation to copyright (including Fair Use) that entitles it to make the Item available.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/20.500.12613/10918
OAI identifier oai:identifier
oai:scholarshare.temple.edu:20.500.12613/10918

Chain of custody

source
Harvested from
Temple University
Base URL
scholarshare.temple.edu/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
related terms
citation

Ghassemi, Ghazal Ghassemi. ACCURACY OF SURVEYED CROWN DESIGN DUPLICATION WITH CAD/CAM TECHNOLOGY COMPARED WITH CONVENTIONAL METHODS IN PARTIALLY EDENTULOUS KENNEDY CLASS III ARCH FORM. Temple University. Libraries, 2024. http://hdl.handle.net/20.500.12613/10918