Back to results

Syracuse University

A NOVEL APPROACH TO NEAR-REAL TIME MONITORING OF VENTILATION RATE AND INDOOR AIR QUALITY IN RESIDENTIAL HOUSES

Abstract

dc:description.abstract

<p>Physics-based infiltration models, like Lawrence Berkeley Laboratory (LBL) and Alberta Infiltration Model (AIM-2), have been used to predict infiltration rate in near real time. These models are constructed from the driving forces of wind and temperature difference across the building enclosure system, both of which cause pressure differences across the enclosure system for infiltration. The models incorporate other major factors like building leakage characteristics, distributions of openings, microenvironment conditions around the building enclosure as affected by building shields, topography and building shape. The accuracy of the models dependents on getting these factors right. However, these factors are specific for individual buildings and measuring these factors in occupied buildings is difficult. In theory, these can be determined by using a generalized table and blower door test but it requires heavy equipment and skilled work force, which is difficult to implement in occupied houses.</p> <p>In this dissertation, a methodology is developed to determine the air change rate (ACH) and indoor air quality (IAQ) in near-real time by combining a physics-based infiltration model with a tracer gas decay test method. The methodology is applicable to naturally ventilated houses. Existing infiltration models are modified explicitly to include the impact of the wind direction. The input data for the model also include indoor air temperature and weather data. Tracer gas method is used to determine the infiltration model parameters using a multi variable nonlinear regression analysis. Once these parameters are obtained, it is able to predict the ACH with 10% and 16% error for AIM-2 and LBL models, respectively. This method does not require the blower door test. Furthermore, a low cost device, a combination of CO_2 sensor, solenoid valve and temperature sensor, has been developed to apply the methodology to measure ACH and IAQ in near-real time without the need for skilled personnel.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Mechanical and Aerospace Engineering
Year
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tirfe, Achalu Kuma
Contributors dc:contributor
  • Jianshun Zhang

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
Repository record dc:identifier
https://surface.syr.edu/etd/768
OAI identifier oai:identifier
oai:surface.syr.edu:etd-1769

Chain of custody

source
Harvested from
Syracuse University
Base URL
surface.syr.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation