Back to results

University of Strathclyde

Application of the FMCW method to quasi-distributed absorption sensors

Abstract

dc:description.abstract

We report on different addressing mechanisms for quasi-distributed absorption sensors based on the frequency modulated continuous wave (FMCW) method. The sensor units consist of open-path micro-optic cells constructed from GRIN lenses, each of differing lengths. Guided by initial simulations, two approaches are experimentally investigated and evaluated, namely reference arm addressing and coherence addressing. Reference arm addressing is accomplished by the selection of different length reference arms in a Michelson configuration where each reference arm corresponds to a certain sensing unit. Coherence addressing is achieved by the interferometric mixing of two signals originating from each cell (from the glass/air interfaces). For each method, we show theoretically and experimentally how individual cells can be addressed and the measured signals obtained by suitable choice of cell length, proper modulation of the source and appropriate signal processing. In order to improve sensitivity we present the theoretical analysis of a new scheme based on combining the (FMCW) technique with frequency modulation spectroscopy (FMS). Here we arrange for only one sideband of the rf-modulation to be attenuated by the absorption feature and a new signal, proportional to the absorbance, appears in the output spectrum at a frequency corresponding to the difference between the rf-modulation frequency and the beat frequency of a cell. The method is highly sensitive and applicable to a variety of chemical species with narrow absorption lines, such as in trace gas analysis. We present the mathematical analysis of the proposed method for single and multiple cell systems, using methane detection as an example.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zavrsnik, Miha

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.248640
T10108
OAI identifier oai:identifier
oai:strathclyde:g158bh29z

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Zavrsnik, Miha. Application of the FMCW method to quasi-distributed absorption sensors. doctoral-pg thesis, University of Strathclyde, 2000. https://stax.strath.ac.uk/concern/theses/g158bh29z