Back to results

University of Strathclyde

Clinical investigation of the functional outcome of fixed bearing versus mobile bearing knees

Abstract

dc:description.abstract

Total Knee Arthroplasty is a high-volume and high-cost procedure, with persisting limitations to patient satisfaction. Prosthesis designs aim to restore function whilst providing stability, without joint constraint. This double-blinded randomised controlled trial is the first of its kind where the functional performance of a low congruent fixed (CR DD), ultra-congruent fixed (UC), and ultra-congruent mobile (UCR) bearing Columbus Total Knee Systems were assessed. The pre- and postoperative function of twenty-four osteoarthritic patients was evaluated against nine control participants whilst carrying out activities of daily living. Spatiotemporal, kinematic, and kinetic gait parameters during walking, stair navigation and sloped walking were extracted using fully instrumented motion capture. Questionnaire responses were also recorded. Across all ADLs, postoperative patient function improved, although not to control levels. The average postoperative increase in range of sagittal knee motion across all tasks came to: 7.3±3.1o (CRDD), 4.9±4.9o (UC), 0.7±7.7o (UCR), and peak knee flexion was mostly reduced at postoperative. Both fixed bearing implants presented larger post-surgery hip and ankle kinetics in magnitude, and improved distinction between knee adduction moment maxima, linked to improved loading to the mobile bearing group. Overall, the CRDD group showed more significant changes to preoperative and any significant inter-implant differences at post-surgery was also to this group. The UC and UCR groups showed less improvements during challenging activities, with the UCR group showing some limits to knee extension. The UCR group also self-reported more difficulty, pain, and tiredness than the fixed bearing groups. Kinematic cross talk error significantly impacted the interpretation of non-sagittal kinematics, and small and unequal sample sizes reduced statistical power. Despite the limitations it was concluded that both fixed bearing implants initially outperformed the mobile bearing joint and the CRDD group showed the most prominent improvements. Clinically relevant thresholds for all parameters, would further determine whether functional advantages exist between implant bearing types.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Govind, Cheral
Advisors dc:contributor.advisor
  • Childs, Craig
  • Murphy, Andrew
  • Riches, Philip

Identifiers

dc:identifier.*
Identifier
T16234
Author Identifier
201458326
OAI identifier oai:identifier
oai:strathclyde:bz60cw757

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Govind, Cheral. Clinical investigation of the functional outcome of fixed bearing versus mobile bearing knees. doctoral-pg thesis, University of Strathclyde, 2022. https://stax.strath.ac.uk/concern/theses/bz60cw757