Back to results

University of Strathclyde

Development and validation of a functional outcome measure package for total knee arthroplasty

Abstract

dc:description.abstract

Functional improvement is an important outcome following total knee arthroplasty (TKA). According to recent research, three-dimensional motion analysis is the most scientific method of measuring dynamic knee function. Nevertheless, current protocols are too time consuming and complicated for routine clinical use. This study developed a clinic-appropriate motion capture system, and investigated the feasibility of its use in a clinical environment. A compact motion capture system (Dimensions: 3.5(L)x2.1(H)x1.1(W)m) and bespoke cluster-based biomechanical model were developed. Assessments for quantifying knee range of motion (ROM), knee strength, gait kinematics, and gait stability were incorporated into the software. Most results were reported in real-time. Validation studies of the assessments against clinical standard tools showed few clinically significant differences between the results, suggesting that the assessments could be used as accurate and reliable alternatives to the traditional tools. The system was then used clinically to report the functional outcome of Medacta GMK Sphere TKA patients. Patients underwent functional testing pre-, 6-weeks, and 1-year post-operatively. Average recorded assessment time was 16.8±2.4 minutes. On average, knee ROM, gait kinematics, spatio-temporal parameters of gait and gait stability improved post-operatively. Knee strength decreased over the first year however, suggesting that TKA patients require strength training post operatively in order to optimise functional outcome. The results reported in this trial were generally consistent with the current literature, implying that the system returned valid data for this patient cohort, and that the Medacta GMK Sphere TKA was successful at improving knee function, especially in frontal and transverse planes during gait.To conclude, this thesis has shown that motion capture technology can feasibly be used in the clinical environment to assess the function of TKA patients in an acceptable clinical time frame. The system developed and presented here can therefore justifiably be used clinically to better report the functional outcome of TKA.

Degree

thesis:*
Name dc:type.qualificationname
phd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Tawy, Gwenllian Fflur
Advisors dc:contributor.advisor
  • Rowe, Philip
  • Riches, Philip

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.759427
T15002
Author Identifier
201457957
OAI identifier oai:identifier
oai:strathclyde:7h149p90s

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Tawy, Gwenllian Fflur. Development and validation of a functional outcome measure package for total knee arthroplasty. doctoral-pg thesis, University of Strathclyde, 2017. https://stax.strath.ac.uk/concern/theses/7h149p90s