Back to results

University of Strathclyde

Biocompatibility assessment of a sol-gel modified electrospun ventricular shunt catheter

Abstract

dc:description.abstract

Hydrocephalus is a clinical condition that usually originates froma reduced passage of cerebrospinal fluid from one brain ventricle toanother. The main procedure to treat this condition involves the insertion of a shunt catheter to bypass the blockage and allow the CSFto flow from the ventricles, thus avoiding a possible build-up of intracranial pressure. Such catheters, which are commonly made frommedical grade silicone, are known to be affected by mechanical failures, infection and blockage owing to cerebral tissue infiltration andbacterial colonisation.To decrease cell adhesion and at the same time increase resistanceto bacterial colonisation, medical grade polyurethane was modifiedwith the addition of inorganic modifiers (titanium and zinc) via a solgel process.Both titanium and zinc were successfully incorporated into the polyurethane in an amorphous form, having a strong impact on the microstructure of the fibres, as the presence of the inorganic phase affects the degree of segregation of hard and soft segments typical ofpolyurethanes, and changes the diameter size and distribution of thefibres, with modified materials exhibiting a narrower diameter distribution. Titanium is well dispersed within the fibres, while zinc tendsto segregate on the surface. All electrospun materials are effective atabsorbing fluid quickly.The co-action of morphological factors and chemistry is effective incontrolling cell adhesion and bacterial colonisation. Upon exposure tohuman immortalised astrocyte cultures, modified electrospun materials exhibit a significantly lower viability than the positive control, anda higher apoptotic rate than the negative control (PDMS). Preliminaryresults suggest that cell adhesion is lower for materials with smallerfibre diameters.Furthermore, results from bacterial colonisation studies show thatnanostructured surfaces are effective in controlling and reducing Staphylococcus aureus colonisation (1 log₁₀ unit reduction), as compared tothe standard silicone.

Degree

thesis:*
Name dc:type.qualificationname
engd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Erbogasto, Davide
Advisor dc:contributor.advisor
  • Black, Richard

Identifiers

dc:identifier.*
Identifier
T15613
Author Identifier
201392985
OAI identifier oai:identifier
oai:strathclyde:7h149p84n

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Erbogasto, Davide. Biocompatibility assessment of a sol-gel modified electrospun ventricular shunt catheter. doctoral-pg thesis, University of Strathclyde, 2020. https://stax.strath.ac.uk/concern/theses/7h149p84n