{"id":{"repo_id":"southwales","oai_identifier":"oai:pure.atira.dk:studenttheses/9622924e-5d7f-4a17-b807-114f8400eeaf"},"canonical_url":"https://search.dev.ndltd.org/etd/southwales/oai:pure.atira.dk:studenttheses/9622924e-5d7f-4a17-b807-114f8400eeaf","repository":{"repo_id":"southwales","name":"University of South Wales","base_url":"https://pure.southwales.ac.uk/ws/oai"},"display":{"title":"Next Generation Monitoring of Critical Welsh Infrastructure: Creating a Starting Point for Integrating Remote Monitoring Data","abstract":"Despite the frequent use of geophysics and remote sensing for solving geo-environmental issues, there is no existing system that applies these to monitoring infrastructure in Wales. Taking reservoirs as a particular focus, many of these were built in the Victorian Era, and suffer from problems like leaks that affect the safety of the structure. Here, self-potential is combined with an automated logger, and bespoke software, to test the effectiveness of a more modern monitoring solution for reservoirs. Data was collected over a long period for a site in North Wales. This was then used to test post-processing methods for isolating the target signal of a leak in the structure. The data showing the leak that was collected by the automated system was confirmed by the results of manual processing. As well as a viable signal from the field equipment, the software acting as the back-end was also developed from the initial plan by the experience of the case study.","abstract_html":"Despite the frequent use of geophysics and remote sensing for solving geo-environmental issues, there is no existing system that applies these to monitoring infrastructure in Wales. Taking reservoirs as a particular focus, many of these were built in the Victorian Era, and suffer from problems like leaks that affect the safety of the structure. Here, self-potential is combined with an automated logger, and bespoke software, to test the effectiveness of a more modern monitoring solution for reservoirs. Data was collected over a long period for a site in North Wales. This was then used to test post-processing methods for isolating the target signal of a leak in the structure. The data showing the leak that was collected by the automated system was confirmed by the results of manual processing. As well as a viable signal from the field equipment, the software acting as the back-end was also developed from the initial plan by the experience of the case study.","abstract_has_math":false,"creators":["Farnham, Nicholas"],"institution":null,"degree_name":"Master's Thesis","degree_level":"Student thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Skilling, Ian","Pirrie, Duncan","Powell, Gareth"],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-07-24T04:39:57Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:pure.atira.dk:studenttheses/9622924e-5d7f-4a17-b807-114f8400eeaf"],"render_values":[{"text":"oai:pure.atira.dk:studenttheses/9622924e-5d7f-4a17-b807-114f8400eeaf","href":null,"code":true}]}]},"links":{"outbound_url":"https://pure.southwales.ac.uk/en/studentTheses/9622924e-5d7f-4a17-b807-114f8400eeaf","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Skilling, Ian","Pirrie, Duncan","Powell, Gareth"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["KESSII","European Social Fund"]},{"key":"dc:creator","label":"Author","values":["Farnham, Nicholas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://pure.southwales.ac.uk/en/studentTheses/9622924e-5d7f-4a17-b807-114f8400eeaf"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Student thesis"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Master's Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:pure.atira.dk:studenttheses/9622924e-5d7f-4a17-b807-114f8400eeaf","https://pure.southwales.ac.uk/en/studentTheses/9622924e-5d7f-4a17-b807-114f8400eeaf"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://pure.southwales.ac.uk/files/26662451/NFarnham_MRes_CES.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Despite the frequent use of geophysics and remote sensing for solving geo-environmental issues, there is no existing system that applies these to monitoring infrastructure in Wales. Taking reservoirs as a particular focus, many of these were built in the Victorian Era, and suffer from problems like leaks that affect the safety of the structure. Here, self-potential is combined with an automated logger, and bespoke software, to test the effectiveness of a more modern monitoring solution for reservoirs. Data was collected over a long period for a site in North Wales. This was then used to test post-processing methods for isolating the target signal of a leak in the structure. The data showing the leak that was collected by the automated system was confirmed by the results of manual processing. As well as a viable signal from the field equipment, the software acting as the back-end was also developed from the initial plan by the experience of the case study."]},{"key":"dc:title","label":"Title","values":["Next Generation Monitoring of Critical Welsh Infrastructure: Creating a Starting Point for Integrating Remote Monitoring Data"]}]}],"canonical_facts":{"dc:contributor.advisor":["Skilling, Ian","Pirrie, Duncan","Powell, Gareth"],"dc:contributor.sponsor":["KESSII","European Social Fund"],"dc:creator":["Farnham, Nicholas"],"dc:date":["2024"],"dc:date.issued":["2024"],"dc:description.abstract":["Despite the frequent use of geophysics and remote sensing for solving geo-environmental issues, there is no existing system that applies these to monitoring infrastructure in Wales. Taking reservoirs as a particular focus, many of these were built in the Victorian Era, and suffer from problems like leaks that affect the safety of the structure. Here, self-potential is combined with an automated logger, and bespoke software, to test the effectiveness of a more modern monitoring solution for reservoirs. Data was collected over a long period for a site in North Wales. This was then used to test post-processing methods for isolating the target signal of a leak in the structure. The data showing the leak that was collected by the automated system was confirmed by the results of manual processing. As well as a viable signal from the field equipment, the software acting as the back-end was also developed from the initial plan by the experience of the case study."],"dc:identifier":["oai:pure.atira.dk:studenttheses/9622924e-5d7f-4a17-b807-114f8400eeaf","https://pure.southwales.ac.uk/en/studentTheses/9622924e-5d7f-4a17-b807-114f8400eeaf"],"dc:identifier.uri":["https://pure.southwales.ac.uk/files/26662451/NFarnham_MRes_CES.pdf"],"dc:language":["eng"],"dc:relation.isreferencedby":["https://pure.southwales.ac.uk/en/studentTheses/9622924e-5d7f-4a17-b807-114f8400eeaf"],"dc:title":["Next Generation Monitoring of Critical Welsh Infrastructure: Creating a Starting Point for Integrating Remote Monitoring Data"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Student thesis"],"dc:type.qualificationname":["Master's Thesis"]},"updated_at":"2026-07-24T04:39:57Z"}