{"id":{"repo_id":"southwales","oai_identifier":"oai:pure.atira.dk:studenttheses/2203def1-c89f-46f2-8200-5f724da46f70"},"canonical_url":"https://search.dev.ndltd.org/etd/southwales/oai:pure.atira.dk:studenttheses/2203def1-c89f-46f2-8200-5f724da46f70","repository":{"repo_id":"southwales","name":"University of South Wales","base_url":"https://pure.southwales.ac.uk/ws/oai"},"display":{"title":"Mass Transfer Studies In A 'Finpak' Distillation Column","abstract":"This thesis presents the results of an investigation of the behaviour of a new form of rectification device under vacuum distillation conditions.<br/><br/>The operating conditions were so varied as to not only provide a measure of 'Finpak' column efficiency under a variety of such conditions, but also to illustrate the effect such variables have on the overall distillation efficiency.<br/><br/>The results of the research indicate that the 'Finpak' fractionating column is a suitable contacting device for the investigation of mass transfer processes inhere low liquid rates are employed, such as in vacuum distillation.<br/><br/>With regards to the vacuum distillation process it was shown that column efficiency improved on reducing stillhead pressure, and it is proposed that the increase in efficiency occurs as a result of a reduction in the resistance to mass transfer within the liquid film, which may be as high as 9O % of the total resistance to mass transfer under the low liquid flow conditions employed throughout the study.","abstract_html":"This thesis presents the results of an investigation of the behaviour of a new form of rectification device under vacuum distillation conditions.&lt;br/&gt;&lt;br/&gt;The operating conditions were so varied as to not only provide a measure of &#x27;Finpak&#x27; column efficiency under a variety of such conditions, but also to illustrate the effect such variables have on the overall distillation efficiency.&lt;br/&gt;&lt;br/&gt;The results of the research indicate that the &#x27;Finpak&#x27; fractionating column is a suitable contacting device for the investigation of mass transfer processes inhere low liquid rates are employed, such as in vacuum distillation.&lt;br/&gt;&lt;br/&gt;With regards to the vacuum distillation process it was shown that column efficiency improved on reducing stillhead pressure, and it is proposed that the increase in efficiency occurs as a result of a reduction in the resistance to mass transfer within the liquid film, which may be as high as 9O % of the total resistance to mass transfer under the low liquid flow conditions employed throughout the study.","abstract_has_math":false,"creators":["Llewellyn, W."],"institution":"Polytechnic of Wales","degree_name":"Doctoral Thesis","degree_level":"Student thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1976,"date_issued":"1976","date_published":"1976","updated_at":"2026-07-24T04:39:18Z","subjects":[],"languages":["eng"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:pure.atira.dk:studenttheses/2203def1-c89f-46f2-8200-5f724da46f70"],"render_values":[{"text":"oai:pure.atira.dk:studenttheses/2203def1-c89f-46f2-8200-5f724da46f70","href":null,"code":true}]}]},"links":{"outbound_url":"https://pure.southwales.ac.uk/en/studentTheses/2203def1-c89f-46f2-8200-5f724da46f70","outbound_label":"Repository record","outbound_source":"dc:identifier"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Llewellyn, W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1976"]},{"key":"dc:date.issued","label":"Date","values":["1976"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Polytechnic of Wales"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://pure.southwales.ac.uk/en/studentTheses/2203def1-c89f-46f2-8200-5f724da46f70"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Student thesis"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Doctoral Thesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:pure.atira.dk:studenttheses/2203def1-c89f-46f2-8200-5f724da46f70","https://pure.southwales.ac.uk/en/studentTheses/2203def1-c89f-46f2-8200-5f724da46f70"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://pure.southwales.ac.uk/files/2741162/W._Llewellyn_1976_2059773.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the results of an investigation of the behaviour of a new form of rectification device under vacuum distillation conditions.<br/><br/>The operating conditions were so varied as to not only provide a measure of 'Finpak' column efficiency under a variety of such conditions, but also to illustrate the effect such variables have on the overall distillation efficiency.<br/><br/>The results of the research indicate that the 'Finpak' fractionating column is a suitable contacting device for the investigation of mass transfer processes inhere low liquid rates are employed, such as in vacuum distillation.<br/><br/>With regards to the vacuum distillation process it was shown that column efficiency improved on reducing stillhead pressure, and it is proposed that the increase in efficiency occurs as a result of a reduction in the resistance to mass transfer within the liquid film, which may be as high as 9O % of the total resistance to mass transfer under the low liquid flow conditions employed throughout the study."]},{"key":"dc:title","label":"Title","values":["Mass Transfer Studies In A 'Finpak' Distillation Column"]}]}],"canonical_facts":{"dc:creator":["Llewellyn, W."],"dc:date":["1976"],"dc:date.issued":["1976"],"dc:description.abstract":["This thesis presents the results of an investigation of the behaviour of a new form of rectification device under vacuum distillation conditions.<br/><br/>The operating conditions were so varied as to not only provide a measure of 'Finpak' column efficiency under a variety of such conditions, but also to illustrate the effect such variables have on the overall distillation efficiency.<br/><br/>The results of the research indicate that the 'Finpak' fractionating column is a suitable contacting device for the investigation of mass transfer processes inhere low liquid rates are employed, such as in vacuum distillation.<br/><br/>With regards to the vacuum distillation process it was shown that column efficiency improved on reducing stillhead pressure, and it is proposed that the increase in efficiency occurs as a result of a reduction in the resistance to mass transfer within the liquid film, which may be as high as 9O % of the total resistance to mass transfer under the low liquid flow conditions employed throughout the study."],"dc:identifier":["oai:pure.atira.dk:studenttheses/2203def1-c89f-46f2-8200-5f724da46f70","https://pure.southwales.ac.uk/en/studentTheses/2203def1-c89f-46f2-8200-5f724da46f70"],"dc:identifier.uri":["https://pure.southwales.ac.uk/files/2741162/W._Llewellyn_1976_2059773.pdf"],"dc:language":["eng"],"dc:publisher.institution":["Polytechnic of Wales"],"dc:relation.isreferencedby":["https://pure.southwales.ac.uk/en/studentTheses/2203def1-c89f-46f2-8200-5f724da46f70"],"dc:title":["Mass Transfer Studies In A 'Finpak' Distillation Column"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Student thesis"],"dc:type.qualificationname":["Doctoral Thesis"]},"updated_at":"2026-07-24T04:39:18Z"}