{"id":{"repo_id":"soton","oai_identifier":"oai:eprints.soton.ac.uk:65677"},"canonical_url":"https://search.dev.ndltd.org/etd/soton/oai:eprints.soton.ac.uk:65677","repository":{"repo_id":"soton","name":"University of Southampton","base_url":"https://eprints.soton.ac.uk/cgi/oai2"},"display":{"title":"Vibration control using an adaptive tuned magneto-rheological fluid vibration absorber","abstract":"An adaptive tuned vibration absorber (ATVA) can be used to suppress unwanted vibrations. If the excitation frequency is time harmonic but the frequency changes with time,it is desirable to retune the ATVA so that the natural frequency of the ATVA always coincides with the excitation frequency. One way of achieving this is to adjust the stiffness ofthe ATVA. The key challenge is to change the stiffness in real-time. Tunable fluids such asMagneto-Rheological (MR) fluids, whose properties can be controlled by a magnetic field,may be used to address this challenge.<br/><br/>The subject of this thesis is an ATVA exploiting the changeable properties of MR fluidsin the pre-yield state. The ATVA is designed as a three-layer beam with elastic face platesand MR fluuid in the core. Electromagnets are attached to the top and the bottom layers togenerate a magnetic field. By varying the current supplied to the electromagnets, the shearstiffness of the MR fluid and hence the stiffness of the ATVA can be varied. The vibrationcharacteristics of the ATVA as a function of the magnetic field strength are predicted bya finite element model together with an empirical model for the shear modulus of the MRfluid and a model for the magnetic field applied to the fluid. An MR fluid-filled ATVA wasmanufactured and tested to validate the predictions. This ATVA design allows the naturalfrequency to be changed by 40.6%.<br/><br/>The self-tuning of the MR fluid-filled ATVA can be achieved by integrating an adaptive-passive controller with the ATVA so that its stiffness can be continuously adjusted in real-time. The control aims to drive the cosine of phase angle between the velocities of thehost structure and the ATVA to zero. Various control algorithms, i.e. non-linear proportional, derivative, and proportional-plus-derivative controls, are investigated. Computersimulations and experimental results demonstrate that the MR fluid-filled ATVA is able toretune itself in the order of 0.2 seconds. The ATVA can also maintain the tuned conditionwithin a reasonably wide frequency range between 110 and 146 Hz in the face of changes inthe forcing frequency. The MR fluid-filled ATVA has the potential to substantially reducevibration of a host structure. The proportional-plus-derivative control was found to be thebest control approach for the ATVA.","abstract_html":"An adaptive tuned vibration absorber (ATVA) can be used to suppress unwanted vibrations. If the excitation frequency is time harmonic but the frequency changes with time,it is desirable to retune the ATVA so that the natural frequency of the ATVA always coincides with the excitation frequency. One way of achieving this is to adjust the stiffness ofthe ATVA. The key challenge is to change the stiffness in real-time. Tunable fluids such asMagneto-Rheological (MR) fluids, whose properties can be controlled by a magnetic field,may be used to address this challenge.&lt;br/&gt;&lt;br/&gt;The subject of this thesis is an ATVA exploiting the changeable properties of MR fluidsin the pre-yield state. The ATVA is designed as a three-layer beam with elastic face platesand MR fluuid in the core. Electromagnets are attached to the top and the bottom layers togenerate a magnetic field. By varying the current supplied to the electromagnets, the shearstiffness of the MR fluid and hence the stiffness of the ATVA can be varied. The vibrationcharacteristics of the ATVA as a function of the magnetic field strength are predicted bya finite element model together with an empirical model for the shear modulus of the MRfluid and a model for the magnetic field applied to the fluid. An MR fluid-filled ATVA wasmanufactured and tested to validate the predictions. This ATVA design allows the naturalfrequency to be changed by 40.6%.&lt;br/&gt;&lt;br/&gt;The self-tuning of the MR fluid-filled ATVA can be achieved by integrating an adaptive-passive controller with the ATVA so that its stiffness can be continuously adjusted in real-time. The control aims to drive the cosine of phase angle between the velocities of thehost structure and the ATVA to zero. Various control algorithms, i.e. non-linear proportional, derivative, and proportional-plus-derivative controls, are investigated. Computersimulations and experimental results demonstrate that the MR fluid-filled ATVA is able toretune itself in the order of 0.2 seconds. The ATVA can also maintain the tuned conditionwithin a reasonably wide frequency range between 110 and 146 Hz in the face of changes inthe forcing frequency. The MR fluid-filled ATVA has the potential to substantially reducevibration of a host structure. The proportional-plus-derivative control was found to be thebest control approach for the ATVA.","abstract_has_math":false,"creators":["Hirunyapruk, Chompoonoot"],"institution":"University of Southampton","degree_name":"Ph.D.","degree_level":"doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Mace, Brian","Brennan, Michael"],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009-01","date_published":"2009-01","updated_at":"2026-07-24T04:35:58Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mace, Brian","Brennan, Michael"]},{"key":"dc:creator","label":"Author","values":["Hirunyapruk, Chompoonoot"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2009-01"]},{"key":"dc:date.issued","label":"Date","values":["2009-01"]},{"key":"dc:publisher.commercial","label":"Dc Publisher Commercial","values":["University of Southampton"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Dynamics Group (pre 2011 reorg)","Institute of Sound and Vibration Research"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Southampton"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://eprints.soton.ac.uk/65677/"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["Ph.D."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://eprints.soton.ac.uk/65677/1/P2501.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An adaptive tuned vibration absorber (ATVA) can be used to suppress unwanted vibrations. If the excitation frequency is time harmonic but the frequency changes with time,it is desirable to retune the ATVA so that the natural frequency of the ATVA always coincides with the excitation frequency. One way of achieving this is to adjust the stiffness ofthe ATVA. The key challenge is to change the stiffness in real-time. Tunable fluids such asMagneto-Rheological (MR) fluids, whose properties can be controlled by a magnetic field,may be used to address this challenge.<br/><br/>The subject of this thesis is an ATVA exploiting the changeable properties of MR fluidsin the pre-yield state. The ATVA is designed as a three-layer beam with elastic face platesand MR fluuid in the core. Electromagnets are attached to the top and the bottom layers togenerate a magnetic field. By varying the current supplied to the electromagnets, the shearstiffness of the MR fluid and hence the stiffness of the ATVA can be varied. The vibrationcharacteristics of the ATVA as a function of the magnetic field strength are predicted bya finite element model together with an empirical model for the shear modulus of the MRfluid and a model for the magnetic field applied to the fluid. An MR fluid-filled ATVA wasmanufactured and tested to validate the predictions. This ATVA design allows the naturalfrequency to be changed by 40.6%.<br/><br/>The self-tuning of the MR fluid-filled ATVA can be achieved by integrating an adaptive-passive controller with the ATVA so that its stiffness can be continuously adjusted in real-time. The control aims to drive the cosine of phase angle between the velocities of thehost structure and the ATVA to zero. Various control algorithms, i.e. non-linear proportional, derivative, and proportional-plus-derivative controls, are investigated. Computersimulations and experimental results demonstrate that the MR fluid-filled ATVA is able toretune itself in the order of 0.2 seconds. The ATVA can also maintain the tuned conditionwithin a reasonably wide frequency range between 110 and 146 Hz in the face of changes inthe forcing frequency. The MR fluid-filled ATVA has the potential to substantially reducevibration of a host structure. The proportional-plus-derivative control was found to be thebest control approach for the ATVA."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dc:title","label":"Title","values":["Vibration control using an adaptive tuned magneto-rheological fluid vibration absorber"]}]}],"canonical_facts":{"dc:contributor.advisor":["Mace, Brian","Brennan, Michael"],"dc:creator":["Hirunyapruk, Chompoonoot"],"dc:date":["2009-01"],"dc:date.issued":["2009-01"],"dc:description.abstract":["An adaptive tuned vibration absorber (ATVA) can be used to suppress unwanted vibrations. If the excitation frequency is time harmonic but the frequency changes with time,it is desirable to retune the ATVA so that the natural frequency of the ATVA always coincides with the excitation frequency. One way of achieving this is to adjust the stiffness ofthe ATVA. The key challenge is to change the stiffness in real-time. Tunable fluids such asMagneto-Rheological (MR) fluids, whose properties can be controlled by a magnetic field,may be used to address this challenge.<br/><br/>The subject of this thesis is an ATVA exploiting the changeable properties of MR fluidsin the pre-yield state. The ATVA is designed as a three-layer beam with elastic face platesand MR fluuid in the core. Electromagnets are attached to the top and the bottom layers togenerate a magnetic field. By varying the current supplied to the electromagnets, the shearstiffness of the MR fluid and hence the stiffness of the ATVA can be varied. The vibrationcharacteristics of the ATVA as a function of the magnetic field strength are predicted bya finite element model together with an empirical model for the shear modulus of the MRfluid and a model for the magnetic field applied to the fluid. An MR fluid-filled ATVA wasmanufactured and tested to validate the predictions. This ATVA design allows the naturalfrequency to be changed by 40.6%.<br/><br/>The self-tuning of the MR fluid-filled ATVA can be achieved by integrating an adaptive-passive controller with the ATVA so that its stiffness can be continuously adjusted in real-time. The control aims to drive the cosine of phase angle between the velocities of thehost structure and the ATVA to zero. Various control algorithms, i.e. non-linear proportional, derivative, and proportional-plus-derivative controls, are investigated. Computersimulations and experimental results demonstrate that the MR fluid-filled ATVA is able toretune itself in the order of 0.2 seconds. The ATVA can also maintain the tuned conditionwithin a reasonably wide frequency range between 110 and 146 Hz in the face of changes inthe forcing frequency. The MR fluid-filled ATVA has the potential to substantially reducevibration of a host structure. The proportional-plus-derivative control was found to be thebest control approach for the ATVA."],"dc:format":["text"],"dc:identifier.uri":["https://eprints.soton.ac.uk/65677/1/P2501.pdf"],"dc:publisher.commercial":["University of Southampton"],"dc:publisher.department":["Dynamics Group (pre 2011 reorg)","Institute of Sound and Vibration Research"],"dc:publisher.institution":["University of Southampton"],"dc:relation.isreferencedby":["https://eprints.soton.ac.uk/65677/"],"dc:title":["Vibration control using an adaptive tuned magneto-rheological fluid vibration absorber"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["doctoral"],"dc:type.qualificationname":["Ph.D."]},"updated_at":"2026-07-24T04:35:58Z"}