Back to results

South Dakota State University

Nursing Practices Related to Bedside Electrocardiographic Monitoring

Abstract

dc:description.abstract

The purpose of this study was to examine the practices of nurses related to electrocardiographic (EGG) monitoring. It was a replication of a study by Drew, Ide, and Sparacino with modifications of the tool and methodology. A questionnaire was completed by 41 nurses in attendance at two chapter meetings of the American Association of Critical Care Nurses. Average years of experience with ECG monitoring was 10 years. Most of the nurses had five-electrode/ lead wire systems capable of displaying two simultaneous leads in their units. Lead II was the only lead selected for continuous monitoring with a single channel monitor, and lead II was chosen as one of the leads to monitor with a dual-channel system by 97% of the respondents. None of the respondents were able to correctly place electrodes and connect lead wires to obtain a MCLl or MCL6 lead. Eighty-two percent of the respondents had incorrect electrode placement using a five-electrode/lead wire system; inaccurate placement of the chest electrode accounted for 96% of these errors. Hypotheses testing included comparison of unit of employment with ECG practices and comparison of years of ECG monitoring experience with ECG practices. Increased years of experience had a positive correlation with increased accuracy in choosing an appropriate lead for ECG monitoring of a patient with an acute anteroseptal wall myocardial infarction.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MS)
Level thesis:degree_level
Thesis - University Access Only
Discipline thesis:degree_discipline
Graduate Nursing
Year
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hall, Gail S.
Contributors dc:contributor
  • Sharon Hofland

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 1996 Gail Hall. All rights reserved
Language dc:language
en

Identifiers

dc:identifier.*
Repository record dc:identifier
https://openprairie.sdstate.edu/etd/842
OAI identifier oai:identifier
oai:openprairie.sdstate.edu:etd-1842

Chain of custody

source
Harvested from
South Dakota State University
Base URL
openprairie.sdstate.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Hall, Gail S.. Nursing Practices Related to Bedside Electrocardiographic Monitoring. Thesis - University Access Only thesis, 1996. https://openprairie.sdstate.edu/etd/842