Back to results

Rice University

A study on the resistances to oxygen transport in the microcirculation

Abstract

dc:description.abstract

A study on the resistances to oxygen transport in the microcirculation has been conducted. In Part I of this work, the oxygen permeability of cultured bovine aortic and human umbilical vein endothelial cell monolayers was measured directly in vitro. The monolayers were cultured on silicone rubber membranes and placed in a carefully calibrated diffusion cell immersed in a 37$\sp\circ$C waterbath. The lower and upper chambers of the diffusion cell were filled with well-stirred, degassed saline and flushed with humidified oxygen respectively. The permeability of the endothelial monolayers was determined from the rate of increase of the oxygen partial pressure in the saline, as monitored by a Clark-type polarographic electrode. The lower bound on the permeability of the cultured endothelial monolayer was determined to be 1.42 $\pm$ 0.33 (s.d.) $\times$ 10$\sp{-6}$ cm$\sp2$/sec for bovine aortic endothelial cells and 1.96 $\pm$ 0.52 (s.d.) $\times$ 10$\sp{-6}$ cm$\sp2$/sec for human umbilical vein endothelial cells. The best value of the permeability of human umbilical vein endothelial monolayers determined in this work was 8.73 $\pm$ 3.21 (s.d.) $\times$ 10$\sp{-6}$ cm$\sp2$/sec. This value of permeability indicates that the resistance to oxygen transport in the endothelium is not as high as some previous studies indicate and is not of dominant importance in determining oxygen transport to tissue. In Part II of this work, the effect of hemoglobin S (HbS) polymerization on the oxygen effective diffusivity in sickle erythrocytes was studied at 25$\sp\circ$C using the diffusion cell apparatus. The effective oxygen diffusivity in fully oxygen saturated 10.2 g/dl hemoglobin A (HbA) solution and normal erythrocytes measured in this work were in excellent agreement with prior workers' measurements of diffusivity unfacilitated by hemoglobin. Furthermore, at full oxygen saturation, the effective oxygen diffusivity was not significantly different in sickle and normal erythrocytes. However, when the average oxygen tension in the samples was decreased progressively over the time course of the experiment, the effective diffusivity was significantly different in normal erythrocytes compared to sickle erythrocytes. It can therefore be concluded that HbS polymerization has a significant effect on the resistance to oxygen transport in sickle erythrocytes not fully saturated with oxygen.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering
Grantor
Rice University
Year dc:date.issued
1993

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Liu, Charles Y.
Advisor dc:contributor.advisor
  • Hellums, J. David

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the author, unless otherwise indicated. Permission to reuse, publish, or reproduce the work beyond the bounds of fair use or other exemptions to copyright law must be obtained from the copyright holder.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1911/16646
OAI identifier oai:identifier
oai:repository.rice.edu:1911/16646

Chain of custody

source
Harvested from
Rice University
Base URL
repository.rice.edu/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Liu, Charles Y.. A study on the resistances to oxygen transport in the microcirculation. Doctoral thesis, Rice University, 1993. https://hdl.handle.net/1911/16646