{"id":{"repo_id":"rgu","oai_identifier":"oai:rgu-repository.worktribe.com:2807303"},"canonical_url":"https://search.dev.ndltd.org/etd/rgu/oai:rgu-repository.worktribe.com:2807303","repository":{"repo_id":"rgu","name":"Robert Gordon University","base_url":"https://rgu-repository.worktribe.com/oaiprovider"},"display":{"title":"An evaluation of digital radiography in the imaging of the neonatal chest.","abstract":"Neonatal chest radiography is an area where there has been very limited research. The introduction of Computed Radiography (CR) has provided a new imaging modality that can be used to acquire neonatal chest radiographs and possibly reduce the radiation dose. The aim of this thesis was to design a simple phantom that reproduced the attenuation and scattering characteristics expected for a neonatal chest, and to develop a methodology for assessing image quality in terms of spatial resolution and contrast. Prior to undertaking the experimental phase, a questionnaire was sent out to ascertain the availability of CR in hospitals undertaking paediatric radiography. The results of the questionnaire provided information on the clinical areas where CR was installed and the reasons for selecting CR. The experimental phase of the study involved acquiring images of the phantom with a test object using Screen Film Radiography (SFR) and CR at the exposures used in the Neonatal Unit (NNU), and at half this exposure. The CR images were then assessed on both hard copy and soft copy and compared to SFR which is still considered the gold standard for neonatal chest radiography. The results indicated that soft copy CR was best for viewing the images, particularly at the reduced exposure. As a result it may be possible to acquire follow up images in NNU at a lower exposure, therefore reducing the radiation dose to the patient.","abstract_html":"Neonatal chest radiography is an area where there has been very limited research. The introduction of Computed Radiography (CR) has provided a new imaging modality that can be used to acquire neonatal chest radiographs and possibly reduce the radiation dose. The aim of this thesis was to design a simple phantom that reproduced the attenuation and scattering characteristics expected for a neonatal chest, and to develop a methodology for assessing image quality in terms of spatial resolution and contrast. Prior to undertaking the experimental phase, a questionnaire was sent out to ascertain the availability of CR in hospitals undertaking paediatric radiography. The results of the questionnaire provided information on the clinical areas where CR was installed and the reasons for selecting CR. The experimental phase of the study involved acquiring images of the phantom with a test object using Screen Film Radiography (SFR) and CR at the exposures used in the Neonatal Unit (NNU), and at half this exposure. The CR images were then assessed on both hard copy and soft copy and compared to SFR which is still considered the gold standard for neonatal chest radiography. The results indicated that soft copy CR was best for viewing the images, particularly at the reduced exposure. As a result it may be possible to acquire follow up images in NNU at a lower exposure, therefore reducing the radiation dose to the patient.","abstract_has_math":false,"creators":["Borthwick, Katrina Elizabeth Klaasen"],"institution":"Robert Gordon University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["A. Stewart, D. Graham and B. Ratcliffe"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-07-24T04:10:09Z","subjects":["Neonatal chest x-ray","Radiography","Computed radiography","Radiation dose","Screen film radiography"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:rgu-repository.worktribe.com:2807303","https://doi.org/10.48526/rgu-wt-2807303"],"render_values":[{"text":"oai:rgu-repository.worktribe.com:2807303","href":null,"code":true},{"text":"https://doi.org/10.48526/rgu-wt-2807303","href":"https://doi.org/10.48526/rgu-wt-2807303","code":true}]}]},"links":{"outbound_url":"https://rgu-repository.worktribe.com/2807303/1/BORTHWICK%202007%20An%20evaluation%20of%20digital%20radiography","outbound_label":"Repository record","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["A. Stewart, D. Graham and B. Ratcliffe"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["No Funder Acknowledged (Outputs)"]},{"key":"dc:creator","label":"Author","values":["Borthwick, Katrina Elizabeth Klaasen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2007-06-30"]},{"key":"dc:date.issued","label":"Date","values":["2007"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Robert Gordon University"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://rgu-repository.worktribe.com/output/2807303"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neonatal chest x-ray","Radiography","Computed radiography","Radiation dose","Screen film radiography"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:rgu-repository.worktribe.com:2807303","https://doi.org/10.48526/rgu-wt-2807303"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://rgu-repository.worktribe.com/2807303/1/BORTHWICK%202007%20An%20evaluation%20of%20digital%20radiography"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Neonatal chest radiography is an area where there has been very limited research. The introduction of Computed Radiography (CR) has provided a new imaging modality that can be used to acquire neonatal chest radiographs and possibly reduce the radiation dose. The aim of this thesis was to design a simple phantom that reproduced the attenuation and scattering characteristics expected for a neonatal chest, and to develop a methodology for assessing image quality in terms of spatial resolution and contrast. Prior to undertaking the experimental phase, a questionnaire was sent out to ascertain the availability of CR in hospitals undertaking paediatric radiography. The results of the questionnaire provided information on the clinical areas where CR was installed and the reasons for selecting CR. The experimental phase of the study involved acquiring images of the phantom with a test object using Screen Film Radiography (SFR) and CR at the exposures used in the Neonatal Unit (NNU), and at half this exposure. The CR images were then assessed on both hard copy and soft copy and compared to SFR which is still considered the gold standard for neonatal chest radiography. The results indicated that soft copy CR was best for viewing the images, particularly at the reduced exposure. As a result it may be possible to acquire follow up images in NNU at a lower exposure, therefore reducing the radiation dose to the patient."]},{"key":"dc:title","label":"Title","values":["An evaluation of digital radiography in the imaging of the neonatal chest."]}]}],"canonical_facts":{"dc:contributor.advisor":["A. Stewart, D. Graham and B. Ratcliffe"],"dc:contributor.sponsor":["No Funder Acknowledged (Outputs)"],"dc:creator":["Borthwick, Katrina Elizabeth Klaasen"],"dc:date":["2007-06-30"],"dc:date.issued":["2007"],"dc:description.abstract":["Neonatal chest radiography is an area where there has been very limited research. The introduction of Computed Radiography (CR) has provided a new imaging modality that can be used to acquire neonatal chest radiographs and possibly reduce the radiation dose. The aim of this thesis was to design a simple phantom that reproduced the attenuation and scattering characteristics expected for a neonatal chest, and to develop a methodology for assessing image quality in terms of spatial resolution and contrast. Prior to undertaking the experimental phase, a questionnaire was sent out to ascertain the availability of CR in hospitals undertaking paediatric radiography. The results of the questionnaire provided information on the clinical areas where CR was installed and the reasons for selecting CR. The experimental phase of the study involved acquiring images of the phantom with a test object using Screen Film Radiography (SFR) and CR at the exposures used in the Neonatal Unit (NNU), and at half this exposure. The CR images were then assessed on both hard copy and soft copy and compared to SFR which is still considered the gold standard for neonatal chest radiography. The results indicated that soft copy CR was best for viewing the images, particularly at the reduced exposure. As a result it may be possible to acquire follow up images in NNU at a lower exposure, therefore reducing the radiation dose to the patient."],"dc:identifier":["oai:rgu-repository.worktribe.com:2807303","https://doi.org/10.48526/rgu-wt-2807303"],"dc:identifier.uri":["https://rgu-repository.worktribe.com/2807303/1/BORTHWICK%202007%20An%20evaluation%20of%20digital%20radiography"],"dc:language":["en"],"dc:publisher.institution":["Robert Gordon University"],"dc:relation.isreferencedby":["https://rgu-repository.worktribe.com/output/2807303"],"dc:subject":["Neonatal chest x-ray","Radiography","Computed radiography","Radiation dose","Screen film radiography"],"dc:title":["An evaluation of digital radiography in the imaging of the neonatal chest."],"dc:type":["Thesis"]},"updated_at":"2026-07-24T04:10:09Z"}