{"id":{"repo_id":"rgu","oai_identifier":"oai:rgu-repository.worktribe.com:1677791"},"canonical_url":"https://search.dev.ndltd.org/etd/rgu/oai:rgu-repository.worktribe.com:1677791","repository":{"repo_id":"rgu","name":"Robert Gordon University","base_url":"https://rgu-repository.worktribe.com/oaiprovider"},"display":{"title":"The development of an electrochemical sensing device for controlled drugs.","abstract":"Forensic chemists can be faced with a wide array of substances to test when attending clandestine drug manufacture crime scenes. Whilst many techniques exist at their disposal - such as chemical colour test reagents and immunoassays - these methods are at best semi-quantitative and often subject to false positives. Electrochemical methods of detection offer a potential solution to this problem, as the equipment is portable, cheap and robust. The analysis is quantitative and, if the electrode/electrolyte combination is designed properly, it can be extremely sensitive and selective. The scientific literature contains many examples of voltammetric analyses of controlled drugs. A square wave voltammetric analysis of the novel psychoactive substance benzyl-piperazine is reported here, representing the first time this analysis has been established. A limit of detection of 6 μM was achieved, and resolution against the similar ecstasy-type drug 3-4-methylenedioxymethylamphetamine (MDMA) was demonstrated. Two innovative USB powered prototype potentiostats have been developed. As proof of concept, an ATMega328P microcontroller was used in conjunction with 12-bit digital-to-analog and analog-to-digital converters (MAX532 and MCP3304 respectively). Using ferricyanide for redox at a glassy carbon electrode, reversible cyclic voltammetric analyses and square wave linear calibration (2.7 to 13.7 μM, R2=0.998) were achieved by the first prototype. The second prototype extended the compliance range (from ±2.5 V to ±12 V) and improved the signal to noise ratio. The second prototype also achieved a linear calibration using square wave voltammetry of MDMA (41 to 82 μM, R2=0.995) at a carbon paste electrode.","abstract_html":"Forensic chemists can be faced with a wide array of substances to test when attending clandestine drug manufacture crime scenes. Whilst many techniques exist at their disposal - such as chemical colour test reagents and immunoassays - these methods are at best semi-quantitative and often subject to false positives. Electrochemical methods of detection offer a potential solution to this problem, as the equipment is portable, cheap and robust. The analysis is quantitative and, if the electrode/electrolyte combination is designed properly, it can be extremely sensitive and selective. The scientific literature contains many examples of voltammetric analyses of controlled drugs. A square wave voltammetric analysis of the novel psychoactive substance benzyl-piperazine is reported here, representing the first time this analysis has been established. A limit of detection of 6 μM was achieved, and resolution against the similar ecstasy-type drug 3-4-methylenedioxymethylamphetamine (MDMA) was demonstrated. Two innovative USB powered prototype potentiostats have been developed. As proof of concept, an ATMega328P microcontroller was used in conjunction with 12-bit digital-to-analog and analog-to-digital converters (MAX532 and MCP3304 respectively). Using ferricyanide for redox at a glassy carbon electrode, reversible cyclic voltammetric analyses and square wave linear calibration (2.7 to 13.7 μM, R2=0.998) were achieved by the first prototype. The second prototype extended the compliance range (from ±2.5 V to ±12 V) and improved the signal to noise ratio. The second prototype also achieved a linear calibration using square wave voltammetry of MDMA (41 to 82 μM, R2=0.995) at a carbon paste electrode.","abstract_has_math":false,"creators":["Waddell, Stuart Andrew"],"institution":"Robert Gordon University","degree_name":"PhD","degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["P. Pollard, C. Inverarity, R. Prabhu and C. Fernandez"],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-07-24T04:10:03Z","subjects":["Electrochemical forensics","Forensics","Drug detection","Drug sensing"],"languages":["en"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:rgu-repository.worktribe.com:1677791","https://doi.org/10.48526/rgu-wt-1677791"],"render_values":[{"text":"oai:rgu-repository.worktribe.com:1677791","href":null,"code":true},{"text":"https://doi.org/10.48526/rgu-wt-1677791","href":"https://doi.org/10.48526/rgu-wt-1677791","code":true}]}]},"links":{"outbound_url":"https://rgu-repository.worktribe.com/1677791/1/WADDELL%202019%20The%20development%20of%20an%20electrochemical%20%28FINAL%29","outbound_label":"Repository record","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["P. Pollard, C. Inverarity, R. Prabhu and C. Fernandez"]},{"key":"dc:contributor.sponsor","label":"Sponsor","values":["No Funder Acknowledged (Outputs)"]},{"key":"dc:creator","label":"Author","values":["Waddell, Stuart Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-11-30"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["Robert Gordon University"]},{"key":"dc:relation.isreferencedby","label":"Dc Relation Isreferencedby","values":["https://rgu-repository.worktribe.com/output/1677791"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]},{"key":"dc:type.qualificationname","label":"Dc Type Qualificationname","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrochemical forensics","Forensics","Drug detection","Drug sensing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["oai:rgu-repository.worktribe.com:1677791","https://doi.org/10.48526/rgu-wt-1677791"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://rgu-repository.worktribe.com/1677791/1/WADDELL%202019%20The%20development%20of%20an%20electrochemical%20%28FINAL%29"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Forensic chemists can be faced with a wide array of substances to test when attending clandestine drug manufacture crime scenes. Whilst many techniques exist at their disposal - such as chemical colour test reagents and immunoassays - these methods are at best semi-quantitative and often subject to false positives. Electrochemical methods of detection offer a potential solution to this problem, as the equipment is portable, cheap and robust. The analysis is quantitative and, if the electrode/electrolyte combination is designed properly, it can be extremely sensitive and selective. The scientific literature contains many examples of voltammetric analyses of controlled drugs. A square wave voltammetric analysis of the novel psychoactive substance benzyl-piperazine is reported here, representing the first time this analysis has been established. A limit of detection of 6 μM was achieved, and resolution against the similar ecstasy-type drug 3-4-methylenedioxymethylamphetamine (MDMA) was demonstrated. Two innovative USB powered prototype potentiostats have been developed. As proof of concept, an ATMega328P microcontroller was used in conjunction with 12-bit digital-to-analog and analog-to-digital converters (MAX532 and MCP3304 respectively). Using ferricyanide for redox at a glassy carbon electrode, reversible cyclic voltammetric analyses and square wave linear calibration (2.7 to 13.7 μM, R2=0.998) were achieved by the first prototype. The second prototype extended the compliance range (from ±2.5 V to ±12 V) and improved the signal to noise ratio. The second prototype also achieved a linear calibration using square wave voltammetry of MDMA (41 to 82 μM, R2=0.995) at a carbon paste electrode."]},{"key":"dc:title","label":"Title","values":["The development of an electrochemical sensing device for controlled drugs."]}]}],"canonical_facts":{"dc:contributor.advisor":["P. Pollard, C. Inverarity, R. Prabhu and C. Fernandez"],"dc:contributor.sponsor":["No Funder Acknowledged (Outputs)"],"dc:creator":["Waddell, Stuart Andrew"],"dc:date":["2019-11-30"],"dc:date.issued":["2019"],"dc:description.abstract":["Forensic chemists can be faced with a wide array of substances to test when attending clandestine drug manufacture crime scenes. Whilst many techniques exist at their disposal - such as chemical colour test reagents and immunoassays - these methods are at best semi-quantitative and often subject to false positives. Electrochemical methods of detection offer a potential solution to this problem, as the equipment is portable, cheap and robust. The analysis is quantitative and, if the electrode/electrolyte combination is designed properly, it can be extremely sensitive and selective. The scientific literature contains many examples of voltammetric analyses of controlled drugs. A square wave voltammetric analysis of the novel psychoactive substance benzyl-piperazine is reported here, representing the first time this analysis has been established. A limit of detection of 6 μM was achieved, and resolution against the similar ecstasy-type drug 3-4-methylenedioxymethylamphetamine (MDMA) was demonstrated. Two innovative USB powered prototype potentiostats have been developed. As proof of concept, an ATMega328P microcontroller was used in conjunction with 12-bit digital-to-analog and analog-to-digital converters (MAX532 and MCP3304 respectively). Using ferricyanide for redox at a glassy carbon electrode, reversible cyclic voltammetric analyses and square wave linear calibration (2.7 to 13.7 μM, R2=0.998) were achieved by the first prototype. The second prototype extended the compliance range (from ±2.5 V to ±12 V) and improved the signal to noise ratio. The second prototype also achieved a linear calibration using square wave voltammetry of MDMA (41 to 82 μM, R2=0.995) at a carbon paste electrode."],"dc:identifier":["oai:rgu-repository.worktribe.com:1677791","https://doi.org/10.48526/rgu-wt-1677791"],"dc:identifier.uri":["https://rgu-repository.worktribe.com/1677791/1/WADDELL%202019%20The%20development%20of%20an%20electrochemical%20%28FINAL%29"],"dc:language":["en"],"dc:publisher.institution":["Robert Gordon University"],"dc:relation.isreferencedby":["https://rgu-repository.worktribe.com/output/1677791"],"dc:subject":["Electrochemical forensics","Forensics","Drug detection","Drug sensing"],"dc:title":["The development of an electrochemical sensing device for controlled drugs."],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"],"dc:type.qualificationname":["PhD"]},"updated_at":"2026-07-24T04:10:03Z"}