Back to results

Robert Gordon University

Signal processing techniques for on-line partial discharge monitoring of high voltage electrical machines.

Abstract

dc:description.abstract

Large alternating current electrical machines are found everywhere in modern industry. Traditionally, electrical plants have been highly reliable, primarily because the complexity of their electrical design means that they are generously over-rated. However, modern rotating electrical machines are now designed to stricter specifications and,in addition to this, there is a strong economic incentive to continue running older machines (with relatively good thermal efficiency) up to and beyond their original design lifetimes. It is therefore not surprising that modern rotating plants experience a small but significant number of faults, which eventually lead to failures and subsequent loss of availability. One cause of machine failure is insulation breakdown of the stator winding. This can happen gradually and can be characterised by an increase in partial discharge activity over time. This activity can be measured using a well-documented, non-invasive technique. However, current analyses rely on experts visually interpreting results, and making judgements based upon their knowledge and experience. This work describes a completely new approach to the analysis of partial discharge data. A high speed analogue and digital electronic system was specified, designed and developed, which is capable of directly digitising the partial discharges with an extremely short duration. Modular software routines were designed to control the electronics and display the digitised information for analysis. Additional software analysis routines were developed to process the discharge information over time. A completely new technique was devised to enable the removal of interference signals from the monitored data, which could otherwise prevent accurate analysis of partial discharge severity. Different methods are investigated in order to measure the frequency content of partial discharges. This had never been attempted before, primarily due to the lack of suitable technology. Finally, a suitable frequency analysis algorithm was developed and applied to experimental data, in order to investigate the feasibility of using the frequency content of partial discharges to ascertain their inception point within the stator winding.

Degree

thesis:*
Name dc:type.qualificationname
PhD
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
Robert Gordon University
Year dc:date.issued
1994

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jamieson, John W.
Advisor dc:contributor.advisor
  • S.J. Chalmers and D.G. Edwards

Subjects

dc:subject × 3

Rights

Language dc:language
en

Identifiers

dc:identifier.*
Identifier
oai:rgu-repository.worktribe.com:1584896
OAI identifier oai:identifier
oai:rgu-repository.worktribe.com:1584896

Chain of custody

source
Harvested from
Robert Gordon University
Base URL
rgu-repository.worktribe.com/oaiprovider
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Jamieson, John W.. Signal processing techniques for on-line partial discharge monitoring of high voltage electrical machines.. Doctoral thesis, Robert Gordon University, 1994. https://rgu-repository.worktribe.com/1584896/1/JAMIESON%201994%20Signal%20processing%20techniques