Back to results

Queens University

Bond Strength and Development Length of Sand-Coated GFRP Bars Spaced and Bundled in Normal Strength and Ultra-High-Performance Fibre-Reinforced Concrete

Abstract

dc:description.abstract

This thesis experimentally examines the bond strength and development length (Ld) of three sand- coated glass fibre-reinforced polymer (GFRP) bar sizes (#4, 5 and 8) embedded into ultra-high- performance fibre-reinforced concrete (UHPFRC) with 2% steel fibres. It also examines the Ld of sand-coated #5 GFRP bars bundled in two and three embedded into normal strength concrete (NSC). Both studies followed the RILEM RC5 standard notched beam bond test method. For the first study investigating GFRP bars with three bar diameters (db), concrete cover (C) varied from 20 mm to 55 mm, and embedment lengths (Le) were 4db, 9db and 14db, totalling 42 notched beams. 38 of 42 beams failed by splitting bond failure. ACI CODE-440.11-22 significantly overestimated Ld by factors of 2.0 to 3.5. The Michaud et al. (2021) design equation for Ld does not account for C or db. As such, at lower C/db ratios (i.e. at small concrete covers), it underestimated Ld while at higher C/db ratios (i.e. at larger cover), it overestimated Ld. A new equation for Ld has been developed, accounting for all critical parameters. For the second study investigating #5 GFRP bars spaced and bundled in groups of two and three, a total of 12 notched beams were tested. Clear concrete cover was consistent at 40 mm, while Le varied from 17 to 87db. It was found that bundling bars reduced the maximum attained longitudinal tensile stress at bond failure by 18-31% for two bars and 24-36% for three bars. At the full design tensile strength (ffu), the Ld of bundles of two and three bars were 1.4 and 1.5 times larger, respectively, than spaced bars. As the tensile stress ratio (ff/ffu) reduced from 1.0 to 0.34 (as in compression controlled failure), the Ld of bundles increased up to 1.9 and 2.5 times the spaced bars, respectively. An expression for this variable bundling factor is proposed. ACI CODE-440.11- 22 also underestimated Ld of spaced bars at ffu by 33%. A correction factor of 1.5 is recommended for spaced sand-coated bars with no deformations when the code equation is used.

Degree

thesis:*
Department dc:contributor.department
Civil Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kaufman, Lukas J.
Advisor dc:contributor.supervisor
  • Fam, Amir

Subjects

dc:subject × 6

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/32628
OAI identifier oai:identifier
oai:queensu.scholaris.ca:1974/32628

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
citation

Kaufman, Lukas J.. Bond Strength and Development Length of Sand-Coated GFRP Bars Spaced and Bundled in Normal Strength and Ultra-High-Performance Fibre-Reinforced Concrete. https://hdl.handle.net/1974/32628