Back to results

Queens University

The Impact of Chronic E-Cigarette Use on Flow- Mediated Dilation Elicited by a Sustained Shear Stress Stimulus

Abstract

dc:description.abstract

E-cigarettes, are popular electronic nicotine delivery devices. Acute human, animal and in-vitro models of e-cigarette exposure, have identified significant impairments in vascular endothelial cell (EC) function. The endothelium is a single layer of cells lining the arteries and is crucial to the regulation of vascular health and function, and impairments are known to increase risk for cardiovascular disease. ECs are stimulated by increases in blood flow-associated forces on the arterial walls (known as shear stress), which cause dilation. The standard test of endothelial function in humans involves creating a transient increase in blood flow in a large artery and measuring the endothelial dependent dilation, this is known as reactive hyperemia flow-mediated dilation (RH-FMD). Three previous studies have assessed the impact of chronic e-cigarette use on human endothelial function all using RH-FMD, with only one finding a significant impairment between users and controls. Endothelial function can also be tested by creating sustained increases in blood flow with handgrip exercise, known as sustained stimulus FMD (SS-FMD). There is evidence suggesting that SS-FMD may detect endothelial dysfunction missed by the standard RH-FMD test. The impact of chronic e-cigarette use on SS-FMD has never been investigated. It was hypothesized that e-cigarette users would display significant impairments in endothelial function assessed by SS-FMD regardless of what is observed for RH-FMD. Ten participants were recruited (4 e-cigarette users, 19 ±1 years; 6 control, 21 ± 2 [mean ± SD]) and participated in two laboratory visits in which the endothelial function of the brachial artery was assessed by both RH- and SS-FMD. Data are [mean ± SD]. RH-FMD was significantly impaired in the e-cigarette group (5.25 ± 1.3%, control: 8.85 ± 3.6%; p=0.010). Similarly, SS-FMD was also lower in e-cigarette users, however, while this was a large effect size the difference between groups did not reach significance (e-cigarettes: 5.99 ± 2.61, control 8.54 ± 3.51; p=0.268; Cohen’s d: 0.82). These results suggest that chronic e-cigarette use has the potential to cause endothelial dysfunction when assessed with standard (RH-FMD) and handgrip exercise (SS-FMD) tests. Contrary to our hypothesis, the SS-FMD test appears not to be a more sensitive detector of e- cigarette induced endothelial dysfunction.

Degree

thesis:*
Department dc:contributor.department
Kinesiology and Health Studies

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Curd, Evan D.
Advisor dc:contributor.supervisor
  • Pyke, Kyra

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1974/31824
OAI identifier oai:identifier
oai:queensu.scholaris.ca:1974/31824

Chain of custody

source
Harvested from
Queens University
Base URL
qspace.library.queensu.ca/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
citation

Curd, Evan D.. The Impact of Chronic E-Cigarette Use on Flow- Mediated Dilation Elicited by a Sustained Shear Stress Stimulus. https://hdl.handle.net/1974/31824