{"id":{"repo_id":"queens","oai_identifier":"oai:queensu.scholaris.ca:1974/14705"},"canonical_url":"https://search.dev.ndltd.org/etd/queens/oai:queensu.scholaris.ca:1974/14705","repository":{"repo_id":"queens","name":"Queens University","base_url":"https://qspace.library.queensu.ca/server/oai/request"},"display":{"title":"MIMU sensors for joint kinematic estimation: anatomical landmarking and frame correction","abstract":"The ability to capture human motion allows researchers to evaluate an individual’s gait. Gait can be measured in different ways, from camera-based systems to Magnetic and Inertial Measurement Units (MIMU). The former uses cameras to track positional information of photo-reflective markers, while the latter uses accelerometers, gyroscopes, and magnetometers to measure segment orientation. Both systems can be used to measure joint kinematics, but the results vary because of their differences in anatomical calibrations. The objective of this thesis was to study potential solutions for reducing joint angle discrepancies between MIMU and camera-based systems. The first study worked to correct the anatomical frame differences between MIMU and camera-based systems via the joint angles of both systems. This study looked at full lower body correction versus correcting a single joint. Single joint correction showed slightly better alignment of both systems, but does not take into account that body segments are generally affected by more than one joint. The second study explores the possibility of anatomical landmarking using a single camera and a pointer apparatus. Results showed anatomical landmark position could be determined using a single camera, as the anatomical landmarks found from this study and a camera-based system showed similar results. This thesis worked on providing a novel way for obtaining anatomical landmarks with a single point-and-shoot camera, as well aligning anatomical frames between MIMUs and camera-based systems using joint angles.","abstract_html":"The ability to capture human motion allows researchers to evaluate an individual’s gait. Gait can be measured in different ways, from camera-based systems to Magnetic and Inertial Measurement Units (MIMU). The former uses cameras to track positional information of photo-reflective markers, while the latter uses accelerometers, gyroscopes, and magnetometers to measure segment orientation. Both systems can be used to measure joint kinematics, but the results vary because of their differences in anatomical calibrations. The objective of this thesis was to study potential solutions for reducing joint angle discrepancies between MIMU and camera-based systems. The first study worked to correct the anatomical frame differences between MIMU and camera-based systems via the joint angles of both systems. This study looked at full lower body correction versus correcting a single joint. Single joint correction showed slightly better alignment of both systems, but does not take into account that body segments are generally affected by more than one joint. The second study explores the possibility of anatomical landmarking using a single camera and a pointer apparatus. Results showed anatomical landmark position could be determined using a single camera, as the anatomical landmarks found from this study and a camera-based system showed similar results. This thesis worked on providing a novel way for obtaining anatomical landmarks with a single point-and-shoot camera, as well aligning anatomical frames between MIMUs and camera-based systems using joint angles.","abstract_has_math":false,"creators":["Rogers, Jonathan"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Mechanical and Materials Engineering","school":null,"contributors":[],"advisors":["Li, Qingguo"],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-08-09","date_published":"2016-08-09","updated_at":"2026-07-27T20:35:21Z","subjects":["Optical Motion Capture","Joint Kinematics","Inertial Motion Capture","Biomechanics","Mechanical Engineering","Anatomical Landmarking"],"languages":["eng"],"rights":["Creative Commons - Attribution - CC BY"],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/1974/14705","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mechanical and Materials Engineering"]},{"key":"dc:contributor.supervisor","label":"Supervisor","values":["Li, Qingguo"]},{"key":"dc:creator","label":"Author","values":["Rogers, Jonathan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-07-27 11:41:46.826","2016-08-02 17:45:49.813","2016-08-08 12:53:07.45"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-09T16:50:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-09T16:50:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-08-09"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optical Motion Capture","Joint Kinematics","Inertial Motion Capture","Biomechanics","Mechanical Engineering","Anatomical Landmarking"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Creative Commons - Attribution - CC BY"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1974/14705"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thesis (Master, Mechanical and Materials Engineering) -- Queen's University, 2016-08-08 12:53:07.45"]},{"key":"dc:description.abstract","label":"Abstract","values":["The ability to capture human motion allows researchers to evaluate an individual’s gait. Gait can be measured in different ways, from camera-based systems to Magnetic and Inertial Measurement Units (MIMU). The former uses cameras to track positional information of photo-reflective markers, while the latter uses accelerometers, gyroscopes, and magnetometers to measure segment orientation. Both systems can be used to measure joint kinematics, but the results vary because of their differences in anatomical calibrations. The objective of this thesis was to study potential solutions for reducing joint angle discrepancies between MIMU and camera-based systems. The first study worked to correct the anatomical frame differences between MIMU and camera-based systems via the joint angles of both systems. This study looked at full lower body correction versus correcting a single joint. Single joint correction showed slightly better alignment of both systems, but does not take into account that body segments are generally affected by more than one joint. The second study explores the possibility of anatomical landmarking using a single camera and a pointer apparatus. Results showed anatomical landmark position could be determined using a single camera, as the anatomical landmarks found from this study and a camera-based system showed similar results. This thesis worked on providing a novel way for obtaining anatomical landmarks with a single point-and-shoot camera, as well aligning anatomical frames between MIMUs and camera-based systems using joint angles."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.A.Sc."]},{"key":"dc:title","label":"Title","values":["MIMU sensors for joint kinematic estimation: anatomical landmarking and frame correction"]}]}],"canonical_facts":{"dc:contributor.department":["Mechanical and Materials Engineering"],"dc:contributor.supervisor":["Li, Qingguo"],"dc:creator":["Rogers, Jonathan"],"dc:date":["2016-07-27 11:41:46.826","2016-08-02 17:45:49.813","2016-08-08 12:53:07.45"],"dc:date.accessioned":["2016-08-09T16:50:57Z"],"dc:date.available":["2016-08-09T16:50:57Z"],"dc:date.issued":["2016-08-09"],"dc:description":["Thesis (Master, Mechanical and Materials Engineering) -- Queen's University, 2016-08-08 12:53:07.45"],"dc:description.abstract":["The ability to capture human motion allows researchers to evaluate an individual’s gait. Gait can be measured in different ways, from camera-based systems to Magnetic and Inertial Measurement Units (MIMU). The former uses cameras to track positional information of photo-reflective markers, while the latter uses accelerometers, gyroscopes, and magnetometers to measure segment orientation. Both systems can be used to measure joint kinematics, but the results vary because of their differences in anatomical calibrations. The objective of this thesis was to study potential solutions for reducing joint angle discrepancies between MIMU and camera-based systems. The first study worked to correct the anatomical frame differences between MIMU and camera-based systems via the joint angles of both systems. This study looked at full lower body correction versus correcting a single joint. Single joint correction showed slightly better alignment of both systems, but does not take into account that body segments are generally affected by more than one joint. The second study explores the possibility of anatomical landmarking using a single camera and a pointer apparatus. Results showed anatomical landmark position could be determined using a single camera, as the anatomical landmarks found from this study and a camera-based system showed similar results. This thesis worked on providing a novel way for obtaining anatomical landmarks with a single point-and-shoot camera, as well aligning anatomical frames between MIMUs and camera-based systems using joint angles."],"dc:description.degree":["M.A.Sc."],"dc:identifier.uri":["http://hdl.handle.net/1974/14705"],"dc:language.iso":["eng"],"dc:rights":["Creative Commons - Attribution - CC BY"],"dc:subject":["Optical Motion Capture","Joint Kinematics","Inertial Motion Capture","Biomechanics","Mechanical Engineering","Anatomical Landmarking"],"dc:title":["MIMU sensors for joint kinematic estimation: anatomical landmarking and frame correction"],"dc:type":["thesis"]},"updated_at":"2026-07-27T20:35:21Z"}