Abstract
dc:description.abstractPositron emission tomography (PET) is a well-established functional imaging method used in nuclear medicine. It allows for retrieving information about biochemical and physiological processes in vivo. The currently possible spatial resolution of PET is about 5 mm for brain acquisitions and about 8 mm for whole-body acquisitions, while recent improvements in image reconstruction point to a resolution of 2 mm in the near future. Typical acquisition times range from minutes to hours due to the low signal-to-noise ratio of the measuring principle, as well as due to the monitoring of the metabolism of the patient over a certain time. Therefore, patient motion increasingly limits the possible spatial resolution of PET. In addition, patient immobilisations are only of limited benefit in this context. Thus, patient motion leads to a relevant resolution degradation and incorrect quantification of metabolic parameters. The present work describes the utilisation of a novel motion compensation method for clinical brain PET acquisitions. By using an external motion tracking system, information about the head motion of a patient is continuously acquired during a PET acquisition. Based on the motion information, a newly developed event-based motion compensation algorithm performs spatial transformations of all registered coincidence events, thus utilising the raw data of a PET system - the so-called `list-mode´ data. For routine acquisition of this raw data, methods have been developed which allow for the first time to acquire list-mode data from an ECAT Exact HR+ PET scanner within an acceptable time frame. Furthermore, methods for acquiring the patient motion in clinical routine and methods for an automatic analysis of the registered motion have been developed. For the clinical integration of the aforementioned motion compensation approach, the development of additional methods (e.g. graphical user interfaces) was also part of this work. After development, optimisation and integration of the event-based motion compensation in clinical use, analyses with example data sets have been performed. Noticeable changes could be demonstrated by analysis of the qualitative and quantitative effects after the motion compensation. From a qualitative point of view, image artefacts have been eliminated, while quantitatively, the results of a tracer kinetics analysis of a FDOPA acquisition showed relevant changes in the R0k3 rates of an irreversible reference tissue two compartment model. Thus, it could be shown that an integration of a motion compensation method which is based on the utilisation of the raw data of a PET scanner, as well as the use of an external motion tracking system, is not only reasonable and possible for clinical use, but also shows relevant qualitative and quantitative improvement in PET imaging.
Degree
thesis:*- Level thesis:degree_level
- thesis.doctoral
- Grantor dc:publisher
- Technische Universität Dresden
- Year
- 2009
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Langner, Jens
- Contributors dc:contributor
-
- van den Hoff, Jörg
- Herzog, Hans
Subjects
dc:subject × 33- Positron Emission Tomography
- PET
- tomography
- nuclear medicine
- medicine
- motion compensation
- motion correction
- movement correction
- motion tracking
- head motion
- neurological
- neuro
- list-mode
- listmode
- event-based
- event-driven
- event-by-event
- line
- Positronen-Emissions-Tomographie
- Tomographie
- Nuklearmedizin
- Medizin
- Bewegungskorrektur
- Korrektur
- Patientenbewegung
- Bewegungsverfolgung
- Kopfbewegung
- Hirnuntersuchung
- NeuroPET
- neurologisch
- List-Modus
- Listen-Modus
- Even