{"id":{"repo_id":"qucosa-diss","oai_identifier":"oai:qucosa:de:qucosa:24287"},"canonical_url":"https://search.dev.ndltd.org/etd/qucosa-diss/oai:qucosa:de:qucosa:24287","repository":{"repo_id":"qucosa-diss","name":"QUCOSA","base_url":"http://www.qucosa.de/oai/"},"display":{"title":"Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors","abstract":"In this thesis methods of calibration of the electromagnetic calorimeter of the BABAR experiment will be introduced. Additionally a method was developed to take into account the different energy losses between the edges and centres of the crystals. An improvement of the energy resolution of photons was achieved by 15%, depending on the energy. For Y(4S) and continuum events a momentum spectrum of inclusively produced neutral pions (Y(4S) -&amp;gt; pi0 X and e+e- -&amp;gt; q anti-q -&amp;gt; pi0 X, respectively) was determined. For continuum events also a momentum depending angle distribution was determined. From these distributions the average number of produced pi0 per event was calculated. The results for B decays and continuum events are n(B) =2,268+-0,008+-0,115 and n(Continuum)=3,388+-0,005+-0,172, respectively. These values were compared with Monte Carlo simulations and with other analyses.","abstract_html":"In this thesis methods of calibration of the electromagnetic calorimeter of the BABAR experiment will be introduced. Additionally a method was developed to take into account the different energy losses between the edges and centres of the crystals. An improvement of the energy resolution of photons was achieved by 15%, depending on the energy. For Y(4S) and continuum events a momentum spectrum of inclusively produced neutral pions (Y(4S) -&amp;amp;gt; pi0 X and e+e- -&amp;amp;gt; q anti-q -&amp;amp;gt; pi0 X, respectively) was determined. For continuum events also a momentum depending angle distribution was determined. From these distributions the average number of produced pi0 per event was calculated. The results for B decays and continuum events are n(B) =2,268+-0,008+-0,115 and n(Continuum)=3,388+-0,005+-0,172, respectively. These values were compared with Monte Carlo simulations and with other analyses.","abstract_has_math":false,"creators":["Maly, Enrico"],"institution":"Technische Universität Dresden","degree_name":null,"degree_level":"thesis.doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Schubert, Klaus R.","Menke, Sven","Spaan, Bernhard"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2003,"date_issued":"2003-12-19","date_published":"2003-12-19","updated_at":"2026-07-24T03:58:02Z","subjects":["BABAR","Hadronen","Kalibrierung","Kalorimeter","pi0","calibration","calorimeter","hadrons"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[]},"links":{"outbound_url":null,"outbound_label":null,"outbound_source":null},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Schubert, Klaus R.","Menke, Sven","Spaan, Bernhard"]},{"key":"dc:creator","label":"Author","values":["Maly, Enrico"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:publisher","label":"Institution","values":["Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden","Technische Universität Dresden"]},{"key":"dc:type","label":"Dc Type","values":["doctoralThesis"]},{"key":"thesis:degree_level","label":"Degree Level","values":["thesis.doctoral"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Technische Universität Dresden"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["BABAR","Hadronen","Kalibrierung","Kalorimeter","pi0","calibration","calorimeter","hadrons"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis methods of calibration of the electromagnetic calorimeter of the BABAR experiment will be introduced. Additionally a method was developed to take into account the different energy losses between the edges and centres of the crystals. An improvement of the energy resolution of photons was achieved by 15%, depending on the energy. For Y(4S) and continuum events a momentum spectrum of inclusively produced neutral pions (Y(4S) -&amp;gt; pi0 X and e+e- -&amp;gt; q anti-q -&amp;gt; pi0 X, respectively) was determined. For continuum events also a momentum depending angle distribution was determined. From these distributions the average number of produced pi0 per event was calculated. The results for B decays and continuum events are n(B) =2,268+-0,008+-0,115 and n(Continuum)=3,388+-0,005+-0,172, respectively. These values were compared with Monte Carlo simulations and with other analyses.","In dieser Arbeit werden die Kalibrierungsmethoden des elektromagnetischen Kalorimeters des BABAR-Experiments vorgestellt. Entwickelt wurde dabei eine Methode, die die unterschiedlichen Energieverluste zwischen Kristallrändern und Kristallmitten berücksichtigt. Es wurde dabei eine Verbesserung der Energieauflösung von Photonen, abhängig von der Energie, von bis zu 15% erreicht. Für Y(4S)- und Kontinuumsereignisse wurden die Impulsspektren und für letztere die impulsabhängigen Richtungsverteilungen inklusiv produzierter neutraler Pionen (Y(4S) -&amp;gt; pi0 X bzw. e+e- -&amp;gt; q anti-q -&amp;gt; pi0 X) bestimmt. Aus diesen Verteilungen wurde die mittleren Anzahl erzeugter pi0 pro Ereignis ermittelt. Für B-Zerfälle bzw. Kontinuumsereignisse ergaben sich n(B) =2,268+-0,008+-0,115 bzw. n(Kontinuum)=3,388+-0,005+-0,172. Diese Werte wurden mit Monte-Carlo-Simulationen und mit anderen Analysen verglichen."]},{"key":"dc:title","label":"Title","values":["Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors"]}]}],"canonical_facts":{"dc:contributor":["Schubert, Klaus R.","Menke, Sven","Spaan, Bernhard"],"dc:creator":["Maly, Enrico"],"dc:description.abstract":["In this thesis methods of calibration of the electromagnetic calorimeter of the BABAR experiment will be introduced. Additionally a method was developed to take into account the different energy losses between the edges and centres of the crystals. An improvement of the energy resolution of photons was achieved by 15%, depending on the energy. For Y(4S) and continuum events a momentum spectrum of inclusively produced neutral pions (Y(4S) -&amp;gt; pi0 X and e+e- -&amp;gt; q anti-q -&amp;gt; pi0 X, respectively) was determined. For continuum events also a momentum depending angle distribution was determined. From these distributions the average number of produced pi0 per event was calculated. The results for B decays and continuum events are n(B) =2,268+-0,008+-0,115 and n(Continuum)=3,388+-0,005+-0,172, respectively. These values were compared with Monte Carlo simulations and with other analyses.","In dieser Arbeit werden die Kalibrierungsmethoden des elektromagnetischen Kalorimeters des BABAR-Experiments vorgestellt. Entwickelt wurde dabei eine Methode, die die unterschiedlichen Energieverluste zwischen Kristallrändern und Kristallmitten berücksichtigt. Es wurde dabei eine Verbesserung der Energieauflösung von Photonen, abhängig von der Energie, von bis zu 15% erreicht. Für Y(4S)- und Kontinuumsereignisse wurden die Impulsspektren und für letztere die impulsabhängigen Richtungsverteilungen inklusiv produzierter neutraler Pionen (Y(4S) -&amp;gt; pi0 X bzw. e+e- -&amp;gt; q anti-q -&amp;gt; pi0 X) bestimmt. Aus diesen Verteilungen wurde die mittleren Anzahl erzeugter pi0 pro Ereignis ermittelt. Für B-Zerfälle bzw. Kontinuumsereignisse ergaben sich n(B) =2,268+-0,008+-0,115 bzw. n(Kontinuum)=3,388+-0,005+-0,172. Diese Werte wurden mit Monte-Carlo-Simulationen und mit anderen Analysen verglichen."],"dc:publisher":["Saechsische Landesbibliothek- Staats- und Universitaetsbibliothek Dresden","Technische Universität Dresden"],"dc:subject":["BABAR","Hadronen","Kalibrierung","Kalorimeter","pi0","calibration","calorimeter","hadrons"],"dc:title":["Untersuchung neutraler pi-Mesonen mit dem elektromagnetischen Kalorimeter des BABAR-Detektors"],"dc:type":["doctoralThesis"],"thesis:degree_level":["thesis.doctoral"],"thesis:institution_name":["Technische Universität Dresden"]},"updated_at":"2026-07-24T03:58:02Z"}